Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 12/14/2014 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 34
Site: Galley-Cold Galley
Violation: The utility sink faucet was continuously leaking. A technician corrected this.
Recommendation: Ensure the plumbing system in a food area is maintained in good repair.
Item No.: 22
Site: Galley-Undercounter Dishwash Machine
Violation: The manufacturer's data plate did not include the wash and final sanitizing rinse cycle times.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 20
Site: Galley-
Violation: An orange plastic salad spinner was in the soiled dish storage rack. This salad spinner had three slotted fasteners in the food contact area. Before the end of the inspection, the slotted fasteners were replaced with nonslotted fasteners.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 26
Site: Buffet-Crew Mess
Violation: Inside the juice machine, all juice dispensing ports were soiled with old juice residue. Also, juice residue was surrounding the dispensing ports on the underside of the machine. The juice machine had been previously cleaned and sanitized.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 40
Site: Bar-Top of the Yacht Bar
Violation: The two doors to the pantry did not fully close when the bar was in operation. Clean dishes and ice were stored inside this pantry.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 33
Site: Bar-Piano Bar
Violation: Inside the technical cabinet and on the bottom shelf, gaps surrounded the utility sink drain line and refrigerator drain line where they penetrated the back bulkhead.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: From May 2014, the maintenance records for potable water tanks 8 port and starboard and 7 port and starboard did not document the free residual halogen value. The records stated the halogen value was less than 5 ppm.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Striping
Violation: The potable water lines were striped blue/gray/blue after the chlorine injection point and adjacent to the distribution chlorine station. This was noted on the last inspection.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 08
Site: Potable Water-Cross Connection Control Log
Violation: None of the backflow preventers or air gaps were inspected in the last year. The list had not been updated for a couple years. The two mineralizer air gaps and two international shore connection reduced pressure (RP) backflow preventers were not listed on the log. Results were not available for the testing of the RP backflow preventers.
Recommendation: Inspect backflow prevention devices periodically and replace any failed units. Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
Item No.: 08
Site: Potable Water-Bilge Water Separator
Violation: The vent on the backflow preventer on the potable water line connected to the bilge water separator was leaking, indicating possible malfunction.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 03
Site: Potable Water-Bunkering Records
Violation: On 13 December, the pH was above 7.8 after 30 minutes of bunkering.
Recommendation: Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
Item No.: 10
Site: Recreational Water Facilities-Pool Machinery Room
Violation: The sample line for the analyzer probe was located after the chlorine and acid injection points on the pool return line. This did not give a representative value of the water chemistry within the pool.
Recommendation: Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration.
Item No.: 08
Site: Potable Water-Pool Machinery Room
Violation: The backflow preventer on the hose connection was in disrepair. A portion of the device was broken off.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 10
Site: Recreational Water Facilities-Test Kit
Violation: The ship was using a DPD colormetric test kit to measure the alkalinity of the pool and whirlpool.
Recommendation: Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
Item No.: 09
Site: Recreational Water Facilities-Pool
Violation: The chlorine values measured by the inspector's kit were 0.94, 0.61, 0.91, and 0.62 ppm. The chlorine values measured by the ship's test kit were 0.82 and 1.01 ppm.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm).
Item No.: 44
Site: Recreational Water Facilities-
Violation: The person tasked with testing the pool and whirlpool was using their test kit incorrectly to measure the chlorine values of the pool. During the inspection, the crew member used the high range reagents while testing the pool and the values produced were incorrect. The crew member did not know how to use the low range reagents and test for low range using the test kit.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 05
Site: Potable Water-Far Point
Violation: The far point analyzer read 0.84 ppm. The inspector's test kit measured 0.4 ppm and the ship's kit measured 0.51 ppm. The analyzer was calibrated.
Recommendation: Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program