Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Costa Mediterranea Cruise Line: Costa Crociere S.P.A. Inspection Date: 12/11/2014 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Food Handler Isolation
Violation: Medical staff did not document the last acute gastroenteritis (AGE) symptoms experienced by a crew member. A food handler on the voyage starting on 23 November reported to medical at 08:55 on 29 November after experiencing AGE symptoms the evening prior. The 24-hour follow-up on 30 November indicated that the food handler experienced 3 additional diarrhea episodes after initially reporting to medical on 29 November, but the time of the last episode was not documented. The food handler was released from isolation at 09:00 on 1 December and sent back to work. It could not be determined if the food handler was isolated for the required 48 hours.
Recommendation: Maintain the following records on board for 12 months and make them available for review by VSP during inspections and outbreak investigations: (6) documentation of the date and time of last symptom and clearance to return to work for food and nonfood employees.
Item No.: 06
Site: Potable Water-Far Point Records
Violation: Some of the far point records did not verify the residual chlorine level to be at least 0.2 ppm for at least 16 hours each 24-hour period. On 25 October the chlorine residual level was missing for 15 hours and the chart recorder indicated 'chart recorder error.' No manual samples were recorded. On 20 October the residual chlorine level was less than 0.2 ppm for 11 hours. No notations were made and no manual samples were taken. On 5 October the chlorine residual level was missing for 11 hours. No notations were made and no manual samples were taken. On 16 September the chlorine residual level was missing for 9 hours and the chart recorder indicated 'chart recorder error.' No manual samples were recorded. The vessel was not in VSP's jurisdiction when these violations occurred.
Recommendation:
Item No.: 08
Site: Potable Water-Striping
Violation: The water lines were striped blue/green/blue before the chlorine injection point by the mineralizer and reverse osmosis plant.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 08
Site: Potable Water-Striping
Violation: The eye wash water supply line was striped blue/gray/blue. Staff indicated this was in fact potable water. This was corrected.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 08
Site: Potable Water-Potable Water to Laundry Technical Water
Violation: The air gap between the potable water supply and the technical water was less than 2-times the diameter of the pipe.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 08
Site: Potable Water-Production Records
Violation: On 30 November the evaporator was in use for 9 hours and no chlorine residual was documented. On 8 December the production record was missing due to a computer/printer communication error, and staff were unable to print the record to document the chlorine residual and pH values. Staff reported producing water for 7-8 hours this day. The electronic data logger was based on a real-time system and could only show the previous 24 hours.
Recommendation: After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water. Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
Item No.: 08
Site: Dining Room-Main Dining Room Starboard Beverage Station
Violation: The pipe connected to the intermediate vents of the double check valve backflow prevention device for both coffee machines was sloped lower than at the discharge end by the floor drain which allowed water to collect in the pipe. When the pipe was raised by the inspector a significant amount of water discharged from the pipe indicating a possible failure of the backflow prevention devices.
Recommendation: Ensure the pipe connected to the intermediate vents of the double check valve backflow prevention devices is directed on a downward slope to the floor drain to ensure a leak from the intermediate vents is visible.
Item No.: 08
Site: Dining Room-Main Dining Room Port Beverage Station
Violation: The pipe connected to the intermediate vents of the double check valve backflow prevention device for both coffee machines was sloped lower than at the discharge end by the floor drain which allowed water to collect in the pipe. When the pipe was raised by the inspector a significant amount of water discharged from the pipe indicating a possible failure of the backflow prevention devices.
Recommendation: Ensure the pipe connected to the intermediate vents of the double check valve backflow prevention devices is directed on a downward slope to the floor drain to ensure a leak from the intermediate vents is visible.
Item No.: 08
Site: Galley-Sauce Station
Violation: The pipe connected to the intermediate vent of the double check valve backflow prevention device for combination oven #3 and #4 was sloped lower than at the discharge end by the floor drain which can allowed water to collect in the pipe. This set-up made it difficult to determine if there was a continuous leak from the intermediate vent indicating a possible failure.
Recommendation: Ensure the pipe connected to the intermediate vents of the double check valve backflow prevention devices is directed on a downward slope to the floor drain to ensure a leak from the intermediate vents is visible.
Item No.: 08
Site: Galley-Hot Galley
Violation: The backflow prevention device for the hood cleaning system was continuously leaking indicating a possible failure.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 08
Site: Galley-Club Medusa
Violation: The pipe connected to the intermediate vent of the double check valve backflow prevention device for the single-tank mechanical dishwash machine was below the flood-level rim of the raised floor drain.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
Item No.: 09
Site: Recreational Water Facilities-Forward Pool
Violation: The forward pool had chlorine residual levels of 1.48 ppm and 1.47 ppm, as measured by the inspector's and ship's test kits. During the testing, the forward pool had interactive spray features in operation and users in the pool.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (4) interactive RWFs (activity pools), between 2.0 and 5.0 mg/L (ppm).
Item No.: 09
Site: Recreational Water Facilities-Records
Violation: The recreational water facility records did not contain notations to outline the action taken when the free halogen residual levels were outside the acceptable ranges during open hours. On 9 November the forward pool did not have chlorine residual recorded from 11:00-22:00 and no manual samples were recorded. A note indicated at 11:00 a chlorine probe was changed. On 19 November the chlorine residual of the mid pool was zero for 6 hours. On 16 November and 17 November the chlorine residual of the aft pool was less than 1.0 ppm for approximately 5 hours on both days. On 15 November and 16 November the chlorine residual of the mid whirlpool was less than 3.0 ppm for 3 to 4 hours on both days. The vessel was not in VSP's jurisdiction when these violations occurred.
Recommendation:
Item No.: 10
Site: Recreational Water Facilities-Records
Violation: On 8 December staff was manually recording the chlorine residual and pH values for the recreational water facilities every four hours since the computer was not working, but they were not testing every the whirlpools every hour as required.
Recommendation: In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Forward Pool
Violation: The forward pool was in operation during the inspection and included interactive water features which were spraying and flowing. This interactive water facility was being operated as a swimming pool for the turnover rate and halogenation levels.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours.
Item No.: 11
Site: Medical-Food Handler Isolation
Violation: Medical staff did not document the last acute gastroenteritis (AGE) symptoms experienced by a crew member. A food handler on the voyage starting on 23 November reported to medical at 0855 on 29 November after experiencing AGE symptoms the evening prior. The 24-hour follow-up on 30 November indicated that the food handler experienced 3 additional diarrhea episodes after initially reporting to medical on 29 November, but the time of the last episode was not documented. The food handler was released from isolation at 0900 on 1 December and sent back to work. It could not be determined if the food handler was isolated for the required 48 hours.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work.
Item No.: 16
Site: Galley-Buffet Pantry
Violation: The undercounter refrigeration units 4811.093.026 and 4811.093.029 were labeled as time control units but were not listed on the posted time control plan.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 16
Site: Buffet-Forward Line Starboard
Violation: The undercounter refrigeration unit 4811.093.113 was listed on the posted time control plan as a time control unit but was not labeled as such.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 19
Site: Room Service-Flower Preparation
Violation: Several roses were stored in a reach-in refrigerator unit designated only for flower storage. According to staff the roses were cut and prepared in the soiled warewash area and then stored in the refrigerator for service.
Recommendation: Do not store flowers in food areas.
Item No.: 19
Site: Provisions-Tobacco Room
Violation: Several cases of liquor were stored in this room that did not have a hard, easily cleanable bulkhead or deckhead. Exposed wires were hanging from the deckhead and the bulkhead/deck juncture was not coved.
Recommendation: Do not store foods: (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
Item No.: 21
Site: Galley-Aft Grill Port Side
Violation: The grease traps on the grooved and flat grills had an open seam around the chute on the underside of the grills.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Healthy Corner Cold Buffet
Violation: The stainless steel plate on the far left end of the cold buffet countertop was not sealed completely to the countertop which created an difficult to clean seam around the plate.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Forward Pool Grill Starboard
Violation: The grease traps on the grooved and flat grills had an open seam around the chute on the underside of the grills.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Pot Wash
Violation: The temperature gauge on the sanitizing compartment of the three-compartment sink indicated 100°C but the water temperature was 89°C when measured by the inspector.
Recommendation: Ensure water temperature-measuring devices are scaled: (1) in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to within 1.5°C (within 3°F) in the intended range of use; (2) only in Fahrenheit are designed to be accurate to within 3°F in the intended range of use.
Item No.: 22
Site: Galley-Warewash
Violation: The far left final rinse spray nozzle of the in-use mechanical dishwash machine was partially blocked creating an ineffective spray pattern.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Galley-Mechanical Pot Wash Machine
Violation: The final rinse temperature of the in-use potwash machine was measured at 156°F by the inspector and 156°F and 157°F by crew. A 150°F/160°F/170°F maximum registering thermolabel was placed on a metal hotel pan and only changed color on the 150°F line. A 180°F maximum registering thermolabel was placed on the final rinse manifold and also did not change color, indicating the temperature was not reached.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 28
Site: Galley-Clean Storage Rack
Violation: Two stacks of hotel pans were not properly air dried and stored wet.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 28
Site: Galley-Hot Galley
Violation: Three different stacks of clean plates stored in the hot plate carts were not covered or inverted.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 33
Site: Provisions-Tobacco Room
Violation: Several cases of liquor were stored in this room that did not have a hard, easily cleanable bulkhead or deckhead. Exposed wires were hanging from the deckhead and the bulkhead/deck juncture was not coved.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 33
Site: Buffet-Lido Starboard Back Service Line
Violation: The technical compartment to the right of the hot counter had two gaps around wiring coming through the side and back bulkhead.
Recommendation: Close the gaps in the technical compartment.
Item No.: 33
Site: Buffet-Pizzeria
Violation: The two small exhaust vents above both sides of the buffet counter were heavily soiled with an accumulation of dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 34
Site: Galley-Forward Pool Grill Starboard
Violation: The bucket fill tap under the handwash station was continuously leaking.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 34
Site: Dining Room-Main Dining Room Port Beverage Station
Violation: A metal hotel pan was placed under the water filter for the coffee machines to collect water that was dripping from the water line. The hotel pan was full and water was overflowing in the technical cabinet.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 38
Site: Dining Room-Main Dining Room Port and Starboard Waiter Stations
Violation: Two moveable trolleys with a cold well and sneeze shield were stored at both waiter stations (one at each). According to staff these units had not been used in over a year.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 38
Site: Buffet-Forward Pasta Station
Violation: A total of 5 movable food units were stored on the side of the pasta station. Three of the units had a hot plate surface with an undercounter storage cabinet, one had a large ceramic cooking surface, and the other had basic countertop with a sneeze shield and a neutral undercounter cabinet. According to staff these units had not been used in over a year.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 39
Site: Buffet-Pizzeria
Violation: One small drain fly was noted flying around the buffet.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Hot Galley
Violation: One drain fly was noted by the combination oven.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Preparation Room-Dry Store Room
Violation: Approximately 3 to 4 small drain flies were observed around the stored bags of flour.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 40
Site: Integrated Pest Management-Garbage Room Inspections
Violation: The weekly inspection of the garbage handling area was not documented.
Recommendation: Inspect the garbage handling areas of the vessel at least weekly for the presence of insects, rodents, and other pests. Maintain the results of these inspections in a log.
Item No.: 40
Site: Integrated Pest Management-Incoming Supplies
Violation: Only food provisions were recorded as being checked for pests. Staff stated they check all supplies (e.g. general supplies, engineering supplies, flowers, etc.) for pest but did not document inspections of nonfood items.
Recommendation: Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
Item No.: 42
Site: Children Area-Diaper Station
Violation: The diaper station did not have a handwash sign to advise people to wash their hands after each diaper change.
Recommendation: Post signs in the diaper changing area advising handwashing after each diaper change.
Item No.: 43
Site: Ventilation-AC Station 8.6
Violation: A heavy accumulation of dust was observed on the bottom of the air filter compartment of unit #6.083. A similar finding was noted on the last inspection.
Recommendation: Keep air handling units clean.
Item No.: 44
Site: Recreational Water Facilities-Forward Pool
Violation: The forward pool was in operation during the inspection and included interactive water features which were spraying and flowing. This interactive water facility was being operated as a swimming pool for the turnover rate and halogenation levels. The features were shut off during the inspection, and staff noted they would consult the corporate office. Similar interactive features were noted on the mid pool, but it was closed during the time of inspection.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program