Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 04/28/2015 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 19
Site: Buffet-Deck 7 Terrace Cafe
Violation: There was a build-up of condensate on the deckhead above the entire area in the passenger buffet serving line, and sneeze shield. Black mold was also observed there. No food or food-contact surfaces were impacted.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Buffet-Deck 7 Terrace Cafe
Violation: There was a build-up of condensate on the deckhead above the entire area in the passenger buffet serving line, and sneeze shield. Black mold was also observed there. No food or food-contact surfaces were impacted.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 20
Site: Galley-Deck 7 Galley
Violation: One slotted fastener was found inside the third door near the stone in the stack pizza oven. This was corrected during the inspection.
Recommendation: Replace the slot-head screw inside the oven with a non-slotted fastener.
Item No.: 26
Site: Galley-Deck 7 Galley
Violation: Four previously cleaned ramekins found in two clean storage shelf racks were found soiled with food debris. Both racks of dishware were removed for re-washing.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 29
Site: Galley-Deck 4 Main Galley
Violation: The crew toilet in the main galley was locked while the galley was in service.
Recommendation: Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
Item No.: 21
Site: Galley-Deck 4 Main Galley
Violation: The area under the entire bain marie contained many overlapping electrical connections and hoses and was difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Galley-Deck 4 Main Galley
Violation: The bulkhead in the main galley contained a soft silicone sealant that was peeling off and potentially falling into food. This condition was noted in front of the main stove, over the soup kettle area, pastry, and over the time control lockers mid galley.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Remove peeling sealant.
Item No.: 26
Site: Galley-Deck 4 Main Galley
Violation: There was a build-up of food debris and grease on a previously cleaned floor mixer in the area where the spindle attaches to the blade.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 14
Site: Galley-Deck 4 Main Galley
Violation: An employee preparing bread had a mustache and a goatee and was not wearing any hair restrain for either.
Recommendation: Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
Item No.: 33
Site: Galley-Deck 4 Main Galley - Pastry
Violation: The deck grout in the pastry area was damaged, dirty, and difficult to clean.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 39
Site: Galley-Deck 4 Main Galley - Pastry
Violation: One live filth fly and one live fruit fly were observed adjacent to the pastry and main grill.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 26
Site: Galley-Deck 4 Main Galley
Violation: There was a small build-up of a black particulate in the water bath of the in-use ice machine
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Other-Food Elevator
Violation: The air vents in this elevator were noticeably dusty and dirty beyond a day's accumulation.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Deck 3 Crew Galley - Cold Section
Violation: There was a hard to clean technical space with a condenser line inside that was soiled with a build-up of slime mold. A fruit fly was observed inside this technical space. The technical space was adjacent right of the undercounter reach-in refrigerator.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Galley-Deck 3 Crew Galley - Cold Section
Violation: A live fruit fly was observed inside the technical space adjacent and to the right of the undercounter reach-in refrigerator.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 22
Site: Galley-Deck 4 Main Galley - Dishwash
Violation: Ther was an excessive amount of dirty dishware in this area, beyond the space allocated on the soiled landing tables, and much of these were still in soiled storage waiting to be cleaned from breakfast when the machine was in disrepair. Four live fruit flies were observed among the soiled items.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 39
Site: Galley-Deck 4 Main Galley - Dishwash
Violation: Four live fruit flies were observed among the soiled items stored at the dishwash.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 21
Site: Buffet-Deck 3 Crew Mess
Violation: Many overlapping electrical lines and hoses at the bain marie made the area difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Buffet-Deck 3 Crew Mess
Violation: The area under the over counter microwave oven was difficult to clean and had a accumulation of food debris on the surface.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-Deck 3 Crew Mess
Violation: The area under the over counter microwave oven was difficult to clean and had a accumulation of food debris on the surface.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Provisions-Deck 3 - Chicken Refrigerator
Violation: This area deckhead had a build-up of balck mold and condensate above the thawing chickens. No food was impacted and the area was immediately cleaned.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Bar-Deck 8 - Panorama Bar
Violation: The area inside a technical space beside the refrigerator had a build-up of water that was leaking onto the deck below. The deck was soiled with a visible black mold.
Recommendation: Repair the water leak and clean the deck below.
Item No.: 08
Site: Medical-Medical Center - Patient Toilet
Violation: The patient toilet handwash sink was equipped with a faucet with a flexible spray hose inserted. The resulting connection was a submerged inlet on the sink. Both the hot and cold potable water pipes supplying this sink were not fitted with backflow prevention devices.
Recommendation: Install continuous pressure backflow preventers on the hot and cold water lines supplying the sink.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: There were many references in the different sections of the OPRP where a 1,000 ppm chlorine solution is prescribed for disinfection, but there was no contact time given for maintaining that product on hard surfaces. In the general requirements section 1, there is a procedure specifying application of 1,000 ppm chlorine, followed by rinse or mopping with water, and then re-application of chlorine at a 200 ppm concentration. It was unclear why this was specified as a general requirement, as this same specification is provided in the sections where a food area vomit accident response takes place, and that is appropriate, but for elevated GI illness responses where 1,000 ppm chlorine is used that should be left wet for at least 5 minutes on the surfaces and not rinsed off or re-applied. It was somewhat unclear if these surfaces were physically washed and rinsed prior to the initial 1,000 ppm chlorine application. The plan also refers to cleaning and disinfection of children areas, but there are no child activity areas on this vessel.
Recommendation: Ensure the OPRP is modified to be clear about the concentration and wet contact time for chlorine on surfaces. The plan should be clear about the situations where chlorine is applied at higher levels and removed for re-application at lower levels as an accident response only in food areas. Ensure in the general and other descriptions that surfaces that can be cleaned (e.g.hard surfaces) are washed and rinsed prior to application of a chlorine disinfection. Remove
Item No.: 40
Site: Integrated Pest Management-Mooring Lines - Rat Guards
Violation: The rat guards on the ship's mooring lines were of an open, U-channel desing which did not fully encircle the ropes and offered easy passage of rodents thru the guards and to several access points on the ship.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The backflow prevention devices installed on the passenger launderette washing machines in decks 4, 6, and 8 were not in thre comprehensive listing of backflow prevention devices, and there was no record of any inspection on them. Additionally, the backflow preventers for the deck 4 housekeeping chemical dispensing locker and the mineralizer backflow preventer were not listed.
Recommendation: Update the comprehensive listing of backflow prevention devices to include those installed in the passenger launderette clothes washers, the deck 4 housekeeping chemical locker and the mineralizer. Ensure all are included in the inspection log as well.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The comprehensive listing of backflow prevention devices and methods did not include the plumbing device wher the cross-connection was made. The form used a SMS Hygiene Log from 2009 and it did not have a column to identify the plumbing device to match with the location where the backflow preventer/method was installed.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 41
Site: Medical-Medical Center - Ward Room 1
Violation: In the toilet room inside ward room 1 there was no pictogram or sign posted at the handwash sink to advise users to wash their hands. Also, there was no sign posted on the door to advise use of a paper towel or tissue to open the door upon exit.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
*Inspections scores of 85 or lower are NOT satisfactory