|
|
|
Item No.:
33
|
|
Site:
Dining Room-Serving Bar
|
|
Violation:
There was a hard to clean projector with wires leading into an open hole in the deckhead directly over the serving bar.
|
|
Recommendation:
Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable.
|
|
|
Item No.:
26
|
|
Site:
Galley-Knife Storage
|
|
Violation:
Two previously cleaned knives in the clean storage area contained food debris. The knives were taken out of service.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Galley-Main
|
|
Violation:
The previously cleaned large food mixer midship had food debris in the splash zone above the mixing bowl.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main
|
|
Violation:
There were four cutting boards in the clean area that were heavily scratched and scored, making them difficult to clean.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
28
|
|
Site:
Galley-Main
|
|
Violation:
A crew member was drying wet clean dishware with a towel and not allowing them to air dry.
|
|
Recommendation:
After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main
|
|
Violation:
In the area beside the sign for galley ventilation, there were loose wires through an open hole in the bulkhead.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
38
|
|
Site:
Galley-Main
|
|
Violation:
In the area above food preparation, there was a personal radio device plugged in to an outlet along with another small radio with the power cords on this shelf.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
|
|
|
Item No.:
19
|
|
Site:
Galley-Main Refrigerator
|
|
Violation:
Whole tomatoes ready for preparation were stored in an open service pan. They were stored directly under the condenser and condenser water had dripped into the pan. The tomatoes were removed from service.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-Production Records
|
|
Violation:
Since the last inspection, the potable water production monitoring records did not indicate chlorination of at least 2.0 ppm at least every four hours. Only a start chlorine and pH value were recorded.
|
|
Recommendation:
Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Showers and Sinks
|
|
Violation:
The backflow prevention devices installed on the cabin hot and cold water lines for the showers and sinks were not included on the list of devices.
|
|
Recommendation:
Update the list of backflow prevention devices. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Skin Tank Variance
|
|
Violation:
The ship has four potable water tanks which share walls and tank bottoms with the hull of the vessel. A variance was submitted in December 2014 for procedures using the saline meter readings. VSP returned the variance to the ship with comments for alarm installation and saline meter readings at least every four hours each day As of April 2015, the variance was still pending.
|
|
Recommendation:
Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-International Shore Connection
|
|
Violation:
There was no backflow prevention device installed on the international shore connection for fire. A variance was submitted in December 2014 to allow for the non-return valve. VSP retuned the variance to the ship with suggestions to install a reduced pressure assembly backflow prevention device. Staff explained the corporate office is deciding how to proceed. As of April 2015, the variance was pending.
|
|
Recommendation:
Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Laundry Machines
|
|
Violation:
The list of backflow prevention devices did not include the two continuous pressure devices installed on the hot and cold water lines. These devices were installed in February/March 2015. The list was updated during the inspection.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) decorative water features/fountains; (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities; (4) photographic laboratory developing machines and utility sinks; (5) beauty and barber shop spray-rinse hoses; (6) spa steam generators where essential oils can be added; (7) hose-bib connections; (8) garbage grinders and food waste systems; (9) automatic galley hood washing systems; (10) food service equipment; (11) mechanical warewashing machines; (12) detergent dispensers; (13) hospital and laundry equipment; (14) air conditioning expansion tanks; (15) boiler feed water tanks; (16) fire system; (17) public toilets, urinals, and shower hoses; (18) potable water, bilge, and pumps that require priming; (19) freshwater or saltwater ballast systems; (20) international fire and fire sprinkler water connections (install a reduced pressure assembly); (21) the potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) water softeners for nonpotable fresh water; (23) water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) chemical tanks; (26) other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) black water or combined gray water/black water systems (install an air gap); (28) any other connection to the potable water system where contamination or backflow can occur.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Condensation Pans
|
|
Violation:
The condensation pans were not accessible for inspection.
|
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Records
|
|
Violation:
Staff stated potable water was bunkered for about 45 minutes in Port Everglades on 9 April, but no readings were obtained to include a start value.
|
|
Recommendation:
Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections. Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
|
|