Item No.:
21
|
|
Site:
Galley-Hot Galley - Flat Grills
|
|
Violation:
The grease pan housing was open to the technical area of the grill, which made cleaning difficult.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley - Flat Grills
|
|
Violation:
The technical area of the grill was soiled with old grease residue and debris. Staff stated this technical area was cleaned on a weekly basis.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The dishwasher had water leaking from the doors to the deck while in active use.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
37
|
|
Site:
Galley-Dishwash
|
|
Violation:
Excessive steam was coming from the dishwasher, which caused condensate to accumulate on the deckhead-mounted air cooling units.
|
|
Recommendation:
Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes. Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
36
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
The light intensity was less than 110 lux inside the walk-in refrigerator #13.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
The light intensity was less than 220 lux at the handwash sink.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
36
|
|
Site:
Galley-Hot Galley
|
|
Violation:
The light intensity was less than 110 lux to the right of the combination ovens. This was noted on the last inspection.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
21
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
A gap was noted above the upright refrigerator #28, which was difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
20
|
|
Site:
Galley-Ice Machine #3
|
|
Violation:
Slotted fasteners were observed on the ice thickness probe of the ice machine.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-Decks
|
|
Violation:
The decks were in disrepair in several areas of the main galley. Staff reported this was an ongoing project, and in several areas the deck had already been replaced.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Galley-Dishwash
|
|
Violation:
The light intensity was less than 220 lux at the clean end of the dishwasher.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
13
|
|
Site:
Galley-Dishwash
|
|
Violation:
A visible alarm was indicated on the dishwasher and it was in active use. The dishwasher staff did not know the alarm was going off. The technicians were contacted immediately, and the issue was addressed.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure the supervisor or person in charge of food operations on the vessel monitors that: (9) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused.
|
|
|
Item No.:
24
|
|
Site:
Galley-Dishwash
|
|
Violation:
A bucket of sanitizing solution had a concentration below 50 ppm. This was corrected.
|
|
Recommendation:
Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Amadea Restaurant
|
|
Violation:
The light intensity was less than 220 lux in one of the corners of the waiter station on the port side.
|
|
Recommendation:
In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|
|
Item No.:
36
|
|
Site:
Galley-Combination Ovens
|
|
Violation:
The light intensity was less than 110 lux behind the combination ovens.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Provisions-
|
|
Violation:
Electrical cables were noted over food in the dry store. Electrical cables were noted on the bulkhead above three trolleys for beverage transportation in the provisions corridor.
|
|
Recommendation:
Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable. Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning. Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Transportation Corridor
|
|
Violation:
Approximately 50 beer kegs were stored in the corridor and the deckhead was open with exposed pipes, cables, and ducts. Staff had covered the kegs with plastic wrap and placed stainless steel covers over the kegs to protect them. This was storage issue was noted on the last inspection.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads are easily cleanable. Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Dry Store
|
|
Violation:
Galvanized shelving units were used in the dry store, and food was stored on them. The shelving was maintained clean and no signs of corrosion were noted.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Four Seasons Restaurant
|
|
Violation:
A temporary buffet station was set up in the dining room, and staff reported this was utilized during the lunch service for self-service salads. The deck was carpeted.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
36
|
|
Site:
Dining Room-Four Seasons Restaurant
|
|
Violation:
The light intensity was less than 220 lux at the temporary buffet.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Four Seasons Restaurant
|
|
Violation:
Coving was missing at the two port waiter stations.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Potable Water Forward/Port & Starboard Reserve Tanks
|
|
Violation:
Both potable water tanks shared an outside wall with the hull of the vessel. This tank arrangement was also noted on previous inspections including 07 SEP 2014, 19 FEB 2013, 12 NOV 2012, 20 APR 2011, 12 OCT 2010, and 04 APR 2008. A salinometer was installed on both of the potable tanks during the original construction. (See following item.)
|
|
Recommendation:
Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Potable Water Forward/Port & Starboard Reserve Tanks
|
|
Violation:
The four forward potable water tanks (reserve potable water tank port, potable water tank #1 port, potable water tank #1 starboard, and reserve potable water tank starboard) shared a common forward wall with the aft wall of mixed ballast water in tank #2. Additionally, the forward wall of this ballast tank was shared with the aft wall of water ballast tank #1. Both tanks can be filled with both ballast water from the sea and treated gray water, including pulper waste from water ballast tank #7. This tank arrangement was also noted on previous inspections including 07 SEP 2014, 19 FEB 2013, 12 NOV 2012, 20 APR 2011, 12 OCT 2010, and 04 APR 2008. Since the last inspection, plans have been developed, submitted to the classification society for review and approval and arrangements have been made with the dry dock for doing the required work. Additionally, a variance is needed for the salinometer before the new arrangement is acceptable.
|
|
Recommendation:
Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
|
|
|
Item No.:
29
|
|
Site:
Pantry-Deck 9 Pantry
|
|
Violation:
A hot water supply line was not connected to the handwashing sink in this pantry that has an ice machine for dispensing ice to the passenger cabins.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|