Item No.:
28
|
|
Site:
Bar-Pool
|
|
Violation:
The paper towel dispenser was installed above the bar counter adjacent to the pantry entrance. When the inspector reached for a paper towel after handwashing, water dripped to the counter. A sign was posted stating that no storage was allowed on this part of the counter.
|
|
Recommendation:
Relocate the paper towel dispenser to a location where it will not contaminate the bar counter.
|
|
|
Item No.:
*
|
|
Site:
*General Comments-
|
|
Violation:
The records and procedures in medical, housekeeping, potable water, ventilation, recreational water, and integrated pest management were thorough and complete.
|
|
Recommendation:
|
|
|
Item No.:
36
|
|
Site:
Buffet-Hot Line
|
|
Violation:
The lighting in the hot line area was insufficient and measured 172 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Prime 7 Starboard
|
|
Violation:
The areas inside the two technical spaces adjacent to the undercounter refrigerators were difficult to clean and dusty.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Prime 7 Starboard
|
|
Violation:
The areas inside the two technical spaces adjacent to the undercounter refrigerators were difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
36
|
|
Site:
Galley-Prime 7 Ice Machine
|
|
Violation:
The lighting on the right side of the ice machine was insufficient and measured 26 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
34
|
|
Site:
Buffet-Pool Center Buffet
|
|
Violation:
There was a leak from the water supply to the coffee machine dripping inside the technical compartment.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
28
|
|
Site:
Other-Pool Deck Dining Area
|
|
Violation:
There was a large bird standing on a table that was set for passenger service with silverware rolled in linen napkins.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
26
|
|
Site:
Galley-Clean Storage Dishwash Area
|
|
Violation:
There was a previously cleaned small ramekin that had food residue remaining inside the food contact surface.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Clean Storage Dishwash Area
|
|
Violation:
There was a previously cleaned coffee mug with food residue on the exterior.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
16
|
|
Site:
Galley-Garde Manger
|
|
Violation:
In an under counter refrigerator on time control there was sliced watermelon from the breakfast service that should have been discarded according to the time control plan. The breakfast service had ended by the time the inspector was in the area.
|
|
Recommendation:
If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
27
|
|
Site:
Galley-Knife Locker
|
|
Violation:
Multiple compartments in this locker contained small amounts of food residue and dust.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-Pastry
|
|
Violation:
Technical spaces MG4.15 and MG4.16 contained equipment and wires that were difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry
|
|
Violation:
One house fly was noted in the section.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
21
|
|
Site:
Galley-Ice Machine Adjacent to Wine Cellar
|
|
Violation:
The interior plastic covering under the cuber was deformed and separated from the side of the machine making it difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Clean Dish Storage
|
|
Violation:
There was food on the exterior of a previously cleaned serving dish in this area.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess Serving Line
|
|
Violation:
The lighting over the food in this area measured 122 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Vegetable Walk-in Refrigerator
|
|
Violation:
The bulkhead adjoining the ice cream freezer contained condensation and was soiled with a black substance at the bulkhead junctures.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pastry
|
|
Violation:
The seam on the dough sheeter belt was frayed.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|