Cruise Ship: Pearl Mist Cruise Line: V. Ships Leisure U.S.A. Inspection Date: 05/24/2015 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 40
Site: Integrated Pest Management-Active Surveillance Logs
Violation: The active surveillance logs for pest inspections were not completed. Staff stated that the active inspections were conducted at the same time as the passive monitor inspections but were not recorded. Staff completed the active inspections and the log while the public health inspector was still on board.
Recommendation: Ensure the IPM Plan sets a schedule for periodic active monitoring inspections, including some at night or during periods of no or minimal activity. Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: All four potable water tanks were cleaned and disinfected during the winter lay up: Tanks 1 and 2 in February 2015 and tanks 3 and 4 in April 2015. Staff provided pictures of the procedures, but no documentation was recorded, including the concentration and contact time of the disinfection or the concentration of the water in the tanks before being placed back into service. Staff reported that a chlorine solution of 50 ppm was placed in a spray bottle and the tanks were sprayed and then left for several days before refilling. However, the method using a sprayed solution is only approved by VSP with a concentration of 200 ppm chlorine.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level. If using the disinfection method described in Section 5.3.4.1.7, ensure that the proper chlorine concentration is used.
Item No.: 08
Site: Potable Water-Tank Coating
Violation: During the winter lay up in February 2015, minor touch-up painting was conducted on tanks 1 and 2. There was no documentation that the manufacturer's recommendations for application, drying, and curing were followed. In addition, the specifications from the paint manufacturer and the third party certificate certifying that the paint was approved for potable water use were not maintained on board. Both of these documents were downloaded from the internet before the end of the inspection.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers' recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers' recommendations for application, drying, and curing; and (3) written documentation that the manufacturers' recommendations have been followed for application, drying, and curing.
Item No.: 05
Site: Potable Water-Far Point
Violation: At the far point analyzer, the inspector measured a free halogen residual of 3.83 ppm, 3.83 ppm, 4.19 ppm, 8.42 ppm, and 9.33 ppm. During these tests, the analyzer read 2.84 ppm, 2.86 ppm, 2.96 ppm, 3.80 ppm, and 4.04 ppm, respectively. The ship's test kit read 5.43 ppm when the analyzer read 3.80 ppm. The ship and the inspector were both using the same model Palintest test kit, but the ship was using reagents from a company called Unitor and not the Palintest reagents. During a visual comparison of the inspector's sample and the ship's sample, it was observed that the ship's sample was cloudier and lighter in color. The analyzer was recalibrated by the ship using the inspector's reagents.
Recommendation: Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 06
Site: Potable Water-Far Point
Violation: The free halogen residual at the far point was measured at 8.42 ppm, 9.33 ppm, and over 10 ppm by the inspector. The supply tank was switched and after flushing the water lines throughout the ship for several minutes, the level at the far point was measured at 1.44 ppm by the inspector.
Recommendation: Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
Item No.: 06
Site: Potable Water-Test Kit Secondary Standards
Violation: Secondary standards for the water test kit were not on board the ship.
Recommendation: Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 06
Site: Potable Water-Test Kit Reagents
Violation: The ship was using a Palintest water test kit with reagents from Unitor instead of reagents from Palintest. The inspector was also using the same model Palintest test kit, but with the Palintest reagents. During a visual comparison of the inspector's sample and the ship's sample, it was observed that the ship's sample was cloudier and lighter in color.
Recommendation: Use only reagents provided or approved by the test kit manufacturer.
Item No.: 41
Site: Housekeeping-Bridge Toilet
Violation: There was no sign at the handwashing station advising users to wash their hands. This was corrected.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands.
Item No.: 08
Site: Potable Water-Permeate Water
Violation: The newly installed piping from the two reverse osmosis plants to the chlorination station was not striped blue/gray/blue to indicate permeate water.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: *
Site: Potable Water-Reverse Osmosis
Violation: Several non-vented testable backflow prevention devices (Watts series 007) were installed on the two reverse osmosis plants. It was not clear why these were installed or what parts of the potable water system they were protecting.
Recommendation: Remove the unnecessary backflow prevention devices.
Item No.: 29
Site: Galley-Entance Handwash Sink
Violation: There was a wet sanitizing cloth in the handwash sink.
Recommendation: Ensure handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 20
Site: Galley-Vegetable Preparation
Violation: There was a cutting board stained, deeply scored and soiled in this area. The board was replaced.
Recommendation: Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 26
Site: Galley-Vegetable Preparation
Violation: There was a previously cleaned cutting board stained, deeply scored and soiled in this area. The board was replaced.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Knife Storage
Violation: There were at least 5 previously cleaned but soiled knives and utensils in the clean knife storage cabinet. The cabinet also had food debris in it.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Ice Machine
Violation: There was an opening in the bulkhead where the power cord was connected to the ice machine.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 26
Site: Galley-Clean Dishware
Violation: There was chocolate on the interior of a previously cleaned dessert glass.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Blast Chiller
Violation: There were three containers of prepared condiments for the omelet station consisting of ham, cheese, and tomatoes that were on time control stored in the blast chiller. This unit was not identified on the time control plan as a time control unit and the unit was not labeled as such.
Recommendation: If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 16
Site: Galley-Preparation Area
Violation: There was no discard label on a tray of freshly cut tomatoes on time control on a preparation counter that were to be used for lunch.
Recommendation: Ensure all potentially hazardous foods on time control on preparation counters are labeled with a discard time even if the outlet is open for less than four hours.
Item No.: 26
Site: Galley-Clean Dish Area
Violation: The interior of a previously cleaned ramekin contained food debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Galley-Clean Dish Area
Violation: Three previously cleaned large ceramic dishes were not inverted and were wet. When inverted, water poured from the dishes.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 19
Site: Buffet-Crew Mess
Violation: There was no sneeze shield for the self-service hot line with the bain maries. Corrections were underway during the inspection.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 33
Site: Preparation Room-Deck
Violation: The area to the left of the ice machine under the preparation counter in the far corner had a large buildup of food debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Preparation Room-Sanitizing Bucket
Violation: The solution in the bucket was cloudy and very dirty.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 33
Site: Provisions-Dry Stores Refrigerator
Violation: The area on the deck to the left of the condenser unit had a buildup of food debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Galley-Knife Storage
Violation: There were at least 5 previously cleaned but soiled knives and utensils in the clean knife storage cabinet. The cabinet also had food debris in it.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Dining Room-Consumer Advisory
Violation: Eggs could be cooked to order from the breakfast menu, and there was a consumer advisory at the bottom of the menu. However, there was no asterisk to link the cooked to order eggs to the advisory.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: *
Site: *General Comments-Improvements
Violation: The ship had made significant improvements to the food areas and the potable water system during the winter lay up in order to comply with VSP standards.
Recommendation:
Item No.: 22
Site: Galley-Dishwash Area
Violation: The conveyor dishwash machine was converted to operate with a chlorinated final rinse sanitizer. The dataplate on the machine indicated that a hot water final sanitizing rinse was being used.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
*Inspections scores of 85 or lower are NOT satisfactory