Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Radiance of the Seas Cruise Line: Royal Caribbean International Inspection Date: 06/07/2015 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 25
Site: Galley-Deck 4 - Hot Galley
Violation: Wet wiping clothes were draped on the rims of five empty sanitation buckets.
Recommendation: Restrict wiping cloths to the following: (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
Item No.: 26
Site: Galley-Deck 4 - Aft/Port Beverage Station
Violation: The right most dispensing port of the previously cleaned juice machine had residues of orange juice. This was corrected.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Deck 4 - Soup Station
Violation: Water was leaking from the deckhead at the entrance of the area. This was corrected.
Recommendation: Repair the leak.
Item No.: 25
Site: Galley-Deck 4 - Pastry
Violation: A wiping cloth was immersed in a soiled sanitation solution. This was corrected.
Recommendation: Restrict wiping cloths to the following: (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
Item No.: 22
Site: Galley-Deck 5 - Bakery
Violation: The undercounter warewasher was out of service since 27 May.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 30
Site: Galley-Deck 3 - Toilet Room
Violation: The toilet for the male food employees was not flushing. This was corrected.
Recommendation: Keep toilet fixtures clean and in good repair.
Item No.: 38
Site: Galley-Deck 1 - Equipment Locker
Violation: Christmas decorations were stored along with food equipment and utensils. This was corrected.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 29
Site: Galley-Park Café
Violation: The handwash station at the front counter could not reach a water temperature of 100°F. This was corrected.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet.
Item No.: 36
Site: Galley-Dog House
Violation: The light bulbs of the warming unit were not shielded or shatter-resistant.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 19
Site: Galley-Windjammer Dessert Stations
Violation: A chaffing dish was located at each dessert station and there was no sneeze guard. The chaffing dishes could be left open and leave food unprotected.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 28
Site: Pantry-Pool Bar
Violation: Two large lexan boxes were stored stacked and wet inside the liquor cabinet. This was corrected.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 42
Site: Children Area-3 - 5 Activity Area
Violation: The space between the vinyl couch cushions was soiled with dust and debris.
Recommendation: Ensure surfaces that children touch with their hands are cleaned and disinfected at least daily with products labeled by the manufacturer for that purpose.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program