Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seaventure Cruise Line: Polar Latitudes Inspection Date: 08/06/2013 Inspection Score: 85
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Secondary Standards
Violation: There were no secondary standards available for the water test kit used to measure the free residual chlorine of any of the water systems such as the distant point and the swimming pool. Documentation was shown that the ship is working with the company on obtaining these standards.
Recommendation: Ensure the halogen test kit used to calibrate the halogen analyzer is accurate to within 0.2 mg/L (ppm) for halogen and graduated in increments no greater than 0.2 mg/L (ppm) in the range of free residual halogen normally maintained in the potable water system. Ensure all reagents used with the test kit are not past their expiration dates. Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
Item No.: 37
Site: Galley-Service Pantry #7 Wine Refrigerator
Violation: The condensation fan in the top of this unit was leaking water onto wine bottles stored below.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 37
Site: Galley-Cold Preparation Room
Violation: Water was dripping from the condenser on the inside top of upright refrigerator #10. Water was pooling on containers of tomatoes, lettuce, and cucumbers and on the bottom of the unit.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 16
Site: Galley-Cold Preparation Room
Violation: Potentially hazardous food such as watermelon and cooked noodles were at a temperature of approximately 50°F as measured by the inspector in upright refrigerator #10. The internal temperature of upright refrigerator #10 was measured at 58°F. Upon reviewing the cooling logs it was determined the food was cooled properly and placed in the refrigerator with 2 hours of being found during the inspection. The food was immediately placed back in the blast chiller.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 37
Site: Galley-Cold Preparation Room
Violation: The condenser unit in the undercounter refrigerator #12 was dripping water onto stored product and water was pooling on the bottom of the unit. A deep hotel pan of pastrami, sausage, and other meats stored on the top shelf under the condenser unit had water pooled on the bottom.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The OPRP stated the food areas in the galley should be disinfected with 1000 ppm chlorine and then rinsed with water when more than 2% of passengers or crew were sick with AGE. The OPRP also stated that if more than 200 ppm chlorine was used in food areas when more than 2% of passengers or crew were sick with AGE then the food areas should be rinsed with water.
Recommendation: Do not use more than 200 ppm chlorine in food areas unless there is a fecal or vomit accident. If there is a fecal and vomit accident and 1000 ppm chlorine is used, ensure the area is washed, rinsed and sanitized with 200 ppm chlorine after the initial clean up and disinfection. Revise the OPRP.
Item No.: 08
Site: Potable Water-Potable Water Tanks
Violation: Documentation was provided on all four potable water tanks that were cleaned and disinfected by a contract company in September 2012. The documentation stated the tanks were dechlorinated until a free residual halogen level of less than 5 ppm was reached, but the actual free residual halogen level measured in the tanks before they were put back into service was not provided. This was written on the previous inspection, but additional information was provided by staff to the inspector showing the tanks were dechlorinated.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The backflow prevention device used for most of the cross-connections on the ship was a non-continuous pressure device (S8 Watts), but this device was installed between two valves in the potable water supply system for equipment such as ice machines, washing machines, juice machines, and for hoses that had a spray nozzle. This was written on the previous inspection. Staff provided documentation stating 35 pieces of the Watts 9D-M3 continuous pressure backflow prevention devices had been ordered to replace the S8 devices and will be installed once they arrive.
Recommendation: Install a continuous pressure-type backflow preventer when a valve is located downstream from the backflow preventer.
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: There were no air gaps listed on the cross-connection control log. The ship had at least one air gap where the evaporator water filled the boiler feed tank. This was written on the previous inspection.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 07
Site: Potable Water-International Shore Connection
Violation: The port and starboard fire stations had individual backflow prevention devices and adapters to connect to any fire hose in case of a fire, but the devices were double check valves without test cocks or an intermediate atmospheric vent. This was written on the previous inspection. Staff provided documentation indicating two appropriate double check valves (detector assemblies) with test cocks and intermediate atmospheric vents were purchased for both of these areas and will be permanently installed in both locations once they are received.
Recommendation: Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
Item No.: 08
Site: Potable Water-Distribution System Chlorination
Violation: There was no analyzer controlled post chlorination halogen injection system installed to control the pump dosing when water enters the distribution system from the potable water tanks and there was only one dosing pump installed. Staff stated they relied on the halogen analyzer at the far point to determine if more chlorine was needed for the system and then manually added the chlorine. This was written on the previous inspection.
Recommendation: Ensure the amount of chemicals injected into the potable water system is analyzer controlled.
Item No.: 06
Site: Potable Water-Distribution System Chlorination
Violation: There was no automatic back-up halogen pump installed so that if the primary pump failed, the back-up pump could provide continuous chlorination to the distribution system. A second dosing pump was available, but it had to be connected manually. This was written on the previous inspection.
Recommendation: Install at least one backup halogen pump with an active, automatic switchover feature to maintain the free residual halogen in the event that the primary pump fails, an increase in demand occurs, or the low chlorine alarm sounds.
Item No.: 10
Site: Recreational Water Facilities-Depth Markers
Violation: Depth markers were not displayed in feet so that they could be seen from inside of the pool. This was written on the previous inspection. Depth markers in both meters and feet were installed so they could be seen from the deck. According to staff, the appropriate glue was ordered to install the depth markers in feet.
Recommendation: Prominently display the depth of each RWF that is deeper than 1 meter (3 feet) so that it can be seen from the deck and in the pool. Label depth markers in both feet and meters. Additionally, install depth markers for every 1 meter (3 feet) change in depth.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment Drain
Violation: There was a single blockable gravity drain installed in the pool, but no documentation was provided to indicate this drain met the ASME A112.19.8 requirements. This was written on the previous inspection. No additional documentation could be provided during the inspection indicating this drain would be replaced with one that met the 2011 VSP Operational requirements.
Recommendation: For RWFs with gravity drainage and a single unblockable drain (per ASME A112.19.8), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency.
Item No.: 40
Site: Integrated Pest Management-Active Surveillance and Procedures
Violation: Active surveillance of pests was not conducted during the day and was not conducted in the garbage handling areas. Also, the only procedures provided to the inspector regarding how staff conducted active surveillance were specific to cockroaches and no other pests. No pests had been sighted according to staff, but if pests found, there was no way to document the action taken or if a follow-up inspection would be conducted. Finally, staff stated pesticides were used onboard, but there was no documentation of these pesticides. A training certificate was only provided for one of the two persons applying pesticides onboard. This was written on the previous inspection.
Recommendation: Ensure the IPM Plan sets a schedule for periodic active monitoring inspections, including some at night or during periods of no or minimal activity. Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log. When pests are noted during an inspection, ensure the log includes action taken and follow-up inspection results. Ensure the vessel's IPM Plan includes a record of pesticides used to control pests and vectors. Ensure that the record includes all pesticides currently onboard the vessel and those used in the previous 12 months. Document the training of the pest-control personnel.
Item No.: 10
Site: Recreational Water Facilities-Monitoring
Violation: There was no halogen analyzer or chart recorder installed on the swimming pool return line to monitor pH free residual halogen values. Staff stated the equipment needed in the pool mechanical room would be installed during the upcoming dry dock, but no documentation could be provided.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Sedimentation Tests
Violation: Quarterly sedimentation tests were not being conducted on the sand filter for the swimming pool.
Recommendation: Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. For whirlpool spas and spa pools, ensure inspections and sedimentation tests are done monthly. For all other RWFs, ensure inspections and sedimentation tests are conducted quarterly. Change granular filter media for whirlpool spas and spa pools based on the inspection and sedimentation test results or every 12 months, whichever is more frequent. For all other RWFs, change granular filter media based on the inspection and sedimentation results or per the manufacturer's recommendations, whichever is more frequent. Record the results of both the filter inspection and sedimentation test.
Item No.: 10
Site: Recreational Water Facilities-Secondary Standards
Violation: There were no secondary standards available for the water test kit used to measure the free residual chlorine of any of the water systems such as the distant point and the swimming pool. Documentation was shown that the ship is working with the company on obtaining these standards.
Recommendation: Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 33
Site: Pantry-
Violation: The light cover on the deckhead was cracked to the right of the storage unit containing single service items and there were a few pests that appeared to be bees inside of the light cover.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 29
Site: Galley-Soiled Drop-Off
Violation: The water temperature of the handwash sink was 123°F.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 28
Site: Galley-Warewashing
Violation: Soiled equipment was stacked in front of the clean coffee cup storage racks to the left of the soiled counter.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 16
Site: Galley-Service Pantry Beverage Station
Violation: The time control plan for the milk compartment on the WMF coffee machine did not list specific discard times for breakfast, lunch, and dinner.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet.
Item No.: 21
Site: Galley-Service Pantry Beverage Station
Violation: The electrical wires for the deck-mounted coffee and juice machines were draped on the countertop.
Recommendation: Remove, shorten, or secure the electrical wires so they do not drape on the countertop.
Item No.: 21
Site: Galley-Service Pantry Beverage Station
Violation: There was not enough space between the ice machine, upright refrigerator #6, and upright refrigerator #7 to allow access for cleaning.
Recommendation: Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead.
Item No.: 36
Site: Galley-Service Pantry Beverage Station
Violation: The light intensity behind the deck-mounted ice machine and between upright refrigerators #6 and #7 was less than 110 lux. This was noted in the previous inspection and was scheduled to be addressed during the upcoming dry dock.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 33
Site: Galley-Service Pantry Beverage Station Store
Violation: The deck had missing and recessed grout. This was a repeat violation from the previous inspection. This was planned to be corrected during the September 2013 dry dock.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 36
Site: Dining Room-Waiter Stations
Violation: The light intensity above all the waiter stations could not be raised to 220 lux for cleaning operations. This was scheduled to be addressed during dry dock in September 2013.
Recommendation: In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 19
Site: Galley-Cold Preparation Room
Violation: Water was dripping from the condenser on the inside top of upright refrigerator #10. Water was pooling on containers of tomatoes, lettuce, and cucumbers and on the bottom of the unit. All three containers were discarded.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 20
Site: Galley-Cold Preparation Room
Violation: Upright refrigerator #10 had an internal temperature of 58°F. Potentially hazardous food such as watermelon and cooked noodles were at approximately 50°F. Upon reviewing cooling logs it was determined the potentially hazardous food was cooled properly and placed in the refrigerator within 2 hours of being found during the inspection. The food was immediately placed back in the blast chiller.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item No.: 20
Site: Galley-Cold Preparation Room
Violation: The right side cabinet of undercounter refrigerator #12 had an internal temperature of 52°F.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 16
Site: Galley-Cold Preparation Room
Violation: The right side cabinet of undercounter refrigerator #12 had an internal temperature of 52°F. One hotel pan of deli meats was stored in undercounter refrigerator #12. The internal temperature of this product was 45°F. According to staff, this hotel pan of deli meats was in this refrigerator for longer than 4 hours. Another hotel pan of cooked fish was stored in undercounter refrigerator #12. The internal temperature of this product was 46°F. According to staff, this hotel pan of fish was in the refrigerator for longer than 4 hours. Both hotel pans of food were discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 19
Site: Galley-Cold Preparation Room
Violation: The condenser unit in the undercounter refrigerator #12 was dripping water onto stored product and water was pooling on the bottom of the unit. A deep hotel pan of pastrami, sausage, and other meats stored on the top shelf under the condenser unit had water pooled on the bottom. This entire pan of meats was discarded.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 34
Site: Galley-Fish Preparation Area
Violation: The main pipe from the handwashing sink at the right of the cleaning locker was leaking onto the deck when in use.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 16
Site: Provisions-Dairy Walk-in
Violation: This unit had an internal temperature of 12°C. Staff noticed the high temperature on the morning of 8/4 and submitted a maintenance request immediately. Engineering staff did not work on the refrigerator until the morning of 8/5. Fourteen boxes of raw eggs and several boxes of soft cheeses were stored in this refrigerator above 41°F for over 24 hours. All potentially hazardous food was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 20
Site: Provisions-Dairy Walk-In
Violation: This unit had an internal temperature of 12°C. Staff noticed the high temperature on the morning of 8/4 and submitted a maintenance request immediately. Potentially hazardous foods were being stored in the unit at the time and the foods were not moved to another refrigerator. Engineering staff did not work on the refrigerator until the morning of 8/5. On 8/6 it was verified the compressor in this unit was not working and it was replaced the morning of 8/6.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
Item No.: 33
Site: Galley-Deck and Bulkheads
Violation: There were seams and gaps between the deck and the bulkhead in several areas throughout the galley. This was a repeat from the previous inspection. This was planned to be addressed during the dry dock in September 2013.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Provisions-Dry Store
Violation: There were loose panels and gaps along the seams on the deckhead above the stored flour.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Galley-Equipment
Violation: Duct tape was used in several areas to cover holes in the stainless steel surfaces of equipment in the galley.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 19
Site: Galley-Service pantry #7 Wine Refrigerator
Violation: The condensation fan in the top of this unit was leaking water onto wine bottles stored below.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 20
Site: Galley-Slotted Fasteners
Violation: Several pieces of equipment, such as the juice machines, dough mixer, and combination ovens had slotted fasteners in the food-contact surfaces of the equipment. These items were noted in the previous report. The staff had a detailed plan to replace all slotted fasteners during the dry dock in September 2013.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool
Violation: Staff were not monitoring alkalinity, combined chlorine, or clarity for the pool. Also, there was no flow meter installed on the pool, so the turnover rates and bather loads were calculated based on the pump capacity calculations. Both of these violations were written on the previous inspection.
Recommendation: Monitor and adjust the RWF's flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry. Calculate the turnover rates and bather loads with the actual flow rate. Install a flow meter.
Item No.: 13
Site: Food Service General-Refrigerators
Violation: The dairy walk-in refrigerator in provisions had an internal temperature of 12°C. Staff noticed the high temperature for the unit on the morning of 8/4 and submitted a maintenance request immediately. Potentially hazardous foods were being stored in the unit at the time and the foods were not moved to another refrigerator. Engineering staff did not work on the refrigerator until the morning of 8/5. On 8/6 it was verified the compressor in this unit was not working and it was replaced the morning of 8/6. Fourteen boxes of raw eggs and several boxes of soft cheeses were stored in this refrigerator above 41°F for over 24 hours. In addition, the internal temperatures of upright refrigerators #10 and #12 in the main galley were above 5°C/41°F. Potentially hazardous foods such as meats, watermelon, and cooked noodles were stored in these two units and the internal temperature of the foods were above 5°C/41°F. The food manager in charge should have moved the potentially hazardous food in all three refrigerators since the units were not able to be fixed immediately.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control pints in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program