|
|
|
Item No.:
37
|
|
Site:
Galley-Hot Line
|
|
Violation:
Some condensate was still noted on the bottom of the shelf above the bain marie unit. Where it was dripping onto the back of the counter, no exposed food was being impacted, today. (See item 26 on previous inspection report)
|
|
Recommendation:
Ensure all food preparation rooms have sufficient ventilation to keep them free of excessive condensation.
|
|
|
Item No.:
37
|
|
Site:
Galley-Steam Kettles
|
|
Violation:
Heavy condensate was noted on the deckhead and inside the exhaust hood above the steam kettles. This condition appeared primarily due to the cold air flow to the area from the air conditioning system that created very cold surfaces in this moist air environment. The kettle lids were closed so no food was being impacted at the time of the inspection.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent condensation from collecting on bulkheads and deckheads. Ensure all food preparation rooms have sufficient ventilation to keep them free of excessive heat, steam, and condensation. Ensure ventilation hood systems and devices operate effectively to prevent condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
28
|
|
Site:
Bar-Pool Bar
|
|
Violation:
A tray of clean glasses was stored directly below the hand towel dispenser.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
24
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The final sanitizing rinse spray was a maximum of 107°F on the inspector's thermocouple on successive tries in an active canopy-style rack dishwasher. It was discovered that the booster heater switch had been turned off by the waste can in front of it. The booster heater was turned back on and the machine reached a temperature of greater than 180° in the manifold.
|
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
|
|
|
Item No.:
22
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The temperature problem above was caused by placement of the waste can in front of the clean end of the dishwasher and inadvertently causing the booster heater to be turned off.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. Check machine operational parameters frequently while in use and if problems are detected correct or suspend operations.
|
|
|
Item No.:
22
|
|
Site:
Bar-Galileo Bar
|
|
Violation:
The final rinse pressure ranged between12-14 psi rather than 15-25 psi on the line pressure specified by the manufacturer's data plate. Staff was in the process of adjusting the pressure when the team left the area.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. Ensure the flow pressure of the fresh hot water sanitizing rinse in a warewashing machine is not less than or more than the pressure specified on the manufacturers's data plate as measured in the water line immediately downstream or upstream from the fresh hot water sanitizing rinse control valve.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Poultry Freezer
|
|
Violation:
There were several patches of water on top of a frozen bag of lima beans that were in a cardboard box. Both the box and the bag were wet. The water was coming from a leak in the technical hatch above in the middle of the room next to a deckhead light. The bag was discarded. This was noted on the previous inspection.
|
|
Recommendation:
Do not store foods: (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; and (9) Under other sources of contamination. Protect food from contamination by storing the food: (2) In a clean, dry location; and (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Poultry Freezer
|
|
Violation:
There were several layers of silicone on the deckhead of two technical hatches in this room, one in the center and one to the left of the entrance to this room. The silicone was rough and cracked in several areas, creating a space that was difficult to clean and small gaps in the deckhead. Frozen water had built up around the silicone of the center technical hatch and was dripping onto the box of frozen lima beans below.
|
|
Recommendation:
Ensure deckheads in food storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Vegetable Freezer
|
|
Violation:
The technical hatch was partially sealed to the deckhead with several layers of silicone, but the silicone was rough and cracked in several areas.
|
|
Recommendation:
Ensure equipment attached to the deckheads are easily cleanable. Ensure deckheads in food storage areas are maintained in good repair.
|
|
|
Item No.:
12
|
|
Site:
Preparation Room-
|
|
Violation:
A worker was seen picking up a potato he had dropped on the deck with his gloves and then after discarding the potato he starting to work with potatoes that had just been peeled without changing his gloves or washing his hands.
|
|
Recommendation:
Ensure food employees clean their hands and exposed portions of their arms immediately before engaging in food preparation including working with exposed food, clean equipment and utensils, and unwrapped single-service and single-use articles and: (1) After touching bare human body parts other than clean hands and clean, exposed portions of arms; (2) After using the toilet room; (3) After coughing, sneezing, using a handkerchief or disposable tissue, using tobacco, eating, or drinking; (4) After handling soiled equipment or utensils; (5) During food preparation, as often as necessary to remove soil and contamination and to prevent cross- contamination when changing tasks; (6) When switching between working with raw food and working with ready-to-eat food; (7) Before putting on gloves for working with food or clean equipment and between glove changes; and (8) After engaging in other activities that contaminate the hands.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Housekeeping Pantries
|
|
Violation:
The light intensity behind the ice machines was less than 110 lux on decks 5, 6, and 7. The light intensity behind the ice machines had been corrected on decks 8,9,10, and 11 since the last inspection.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Spa Drains
|
|
Violation:
Safety Vacuum Release Systems (SVRS) had been ordered and were received onboard and according to staff would be installed as soon as possible for the suction fittings in both of the whirlpool spas.
|
|
Recommendation:
For RWFs with suction fittings and a single unblockable drain (per ASME A112.19.8-2007), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Starboard Whirlpool Spa
|
|
Violation:
The inspector and the ship's staff received a reading of 'Hi' when measuring the free chlorine residual value of this spa on two different occasions indicating the value was above 10.0 ppm free residual chlorine. The spa was open during the inspection and immediately netted. The analyzer in the mechanical room had a value of 5.25 ppm as measured by the ship's staff. The ship's staff had the reference standards for their pool test meter. The ship's staff measured a value of 9.03 ppm at the sample line in the mechanical room. The whirlpool spa was netted. A second sample of the whirlpool spa was 'Hi' as measured by the inspector and 9.25 ppm as measured by the ship's staff the analyzer read 7.70 ppm. The whirlpool was closed.
|
|
Recommendation:
Maintain a free residual halogen in recirculated RWFs in the following ranges: (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Starboard Whirlpool Spa
|
|
Violation:
The value between the inspector's test kit and the ship's test kit was greater than 0.2 ppm free residual halogen in this spa every time it was measured.
|
|
Recommendation:
Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF.
|
|