Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Safari Endeavour Cruise Line: Un-Cruise Adventures Inspection Date: 08/25/2013 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Galley-Cold Kitchen
Violation: There was an open pipe penetration in the deckhead between both of the ice machines.
Recommendation: Close the pipe penetration in the deckhead between both of the ice machines.
Item No.: 28
Site: Food Service General-Drain Lines
Violation: The drain lines for the warewashing three compartment sink and the warewashing machine in the bar were directly connected to the ship's waste system. This was written on the previous inspection, but the inspector was shown documentation indicating this would be corrected during the upcoming dry dock.
Recommendation: Ensure all drain lines from warewashing sinks or machines drain through an air gap or air-break to a drain or scupper.
Item No.: 28
Site: Galley-Coffee Station
Violation: There was no splash shield installed between the handwashing sink and the coffee urns at the coffee station. As the inspector was washing their hands, water was splashing onto the coffee urn directly next to the sink.
Recommendation: Install a splash shield between the handwashing sink and the coffee urns or move the coffee urns away from the handwashing sink.
Item No.: 28
Site: Galley-Bakery
Violation: An upside down hotel pan was stored inverted on the deck in order to store containers of chocolate and sugar off the deck.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 17
Site: Galley-Cooling Logs
Violation: None of the cooling logs for several cooked potentially hazardous food items included the initial temperature of the product as the cooling process was started. The time of the initial cooling was documented, but the temperature was only recorded after a two hour time period, a four hour time period and a six hour time period. For example, fried rice was cooked on August 24, 2013, and the cooling process began at 1:30 p.m. After two hours, the temperature of the rice was indicated at 60°F at 3:30 p.m., after four hours the temperature was indicated at 45°F at 5:30 p.m. and after six hours the temperature was indicated at 38°F at 7:30 p.m. According to the chef, it was unknown if the food was already below 135°F when the time was recorded for the initial cooling process. No food that had been cooled was onboard during the inspection.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 19
Site: Galley-Drain Lines
Violation: The drain lines for the preparation and utility sinks were directly connected to the ship's waste system. This was written on the previous inspection, but the inspector was shown documentation indicating this would be corrected during the upcoming dry dock.
Recommendation: Ensure drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
Item No.: *
Site: Galley-Drinking Fountain
Violation: There was no drinking fountain in the main galley and the closest drinking fountain was on deck 3.
Recommendation: Install a drinking fountain in or near the main galley for food workers.
Item No.: 36
Site: Food Service General-Lighting
Violation: The light intensity was less than 110 lux in most of the dry store room including the areas to the right of the stair case, directly across from the stair case and the first areas immediately to the left of the stair case. Also, several areas in the main galley had a light intensity less than 220 lux, including at the plastic bin storage and at the stainless steel hotel pan rack in the bakery area, at the stacked Vulcan ovens on the hot line, at the entry of the soiled and clean landing and at the three-compartment sink in the warewash area, and at the counter of the self-service buffet line in the dining room. These areas were written on the previous inspection. Documentation provided to the inspector indicated all of these areas would be corrected during the upcoming dry dock.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment. Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Bar-Lighting
Violation: The light intensity was not able to be raised to 220 lux for cleaning operations.
Recommendation: In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 21
Site: Galley-Cold Kitchen
Violation: There was approximately 1/2 inch of space between the top of both ice machines and the deckhead at the back of the machines, making this area difficult to clean. This was written on the previous inspection, but many gaps in this same area had been closed.
Recommendation: Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead.
Item No.: 33
Site: Buffet-Coving
Violation: The coving at the deck/counter juncture of the self-service counter was missing or recessed.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 18
Site: Galley-Walk-in Fridge
Violation: There was a container of raw duck breast that was above a container of raw pork chops.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas.
Item No.: 19
Site: Bar-Handwashing Sink
Violation: There was no splash shield between the handwashing sink and several bottles of liquor next to the sink.
Recommendation: Install a splash shield between the handwashing sink and the liquor bottles or move the bottles away from the sink.
Item No.: 30
Site: Bar-Handwashing Sink
Violation: There was no waste receptacle for the handwashing sink.
Recommendation: Ensure a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle.
Item No.: 28
Site: Bar-Utility Sink
Violation: There was no splash shield between the utility sink and the clean storage area where bar equipment and utensils were stored.
Recommendation: Install a splash shield between the utility sink and the clean equipment storage area or store the clean equipment away from the utility sink.
Item No.: 28
Site: Galley-Bakery
Violation: A few hotel pans of different sizes were stored nested and wet on the shelving unit in the bakery.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 22
Site: Galley-Clean Storage
Violation: There was not enough clean storage for all the equipment and utensils in this area. Some of the clean equipment was stored nested and wet in the bakery and several large pieces of equipment were stored in ovens when they were not in-use.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing. Clean storage may be able to be added in the expedited area next to the hot line or above the dry store room hatch.
Item No.: 21
Site: Galley-Hot Line
Violation: There were difficult to clean gaps around the fryer and stacked Vulcan ovens and also to the right side of the preparation counter. A portion of the control panel of the fryer was peeling and had rough surfaces that were difficult to clean. Some of the gaps and difficult to clean areas had been repaired since the last inspection.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Hot Line
Violation: There was a heavy layer of grease to the right of the fryer and inside the void space of the lower right side of the fryer and to the right of the Vulcan ovens. There was no soil or grease on the other pieces of cooking equipment mentioned during the last inspection.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Shelving
Violation: The shelving unit below the bain marie was soiled with food crumbs in a few areas.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Galley-Cooling Logs
Violation: It was unknown if cooked potentially hazardous food was cooled correctly since the cooling logs did not indicate the temperature of the food at the beginning of the cooling process and how long the food had been between 135°F and 70°F.
Recommendation: Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
Item No.: 13
Site: Galley-Cooling Logs
Violation: The chef in charge was not properly documenting the initial cooling temperatures of cooked potentially hazardous food and did not understand the importance of the cooling requirements in the 2011 VSP Operations Manual.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The OPRP did not include procedures to notify current passengers and crew of an outbreak or procedures to notify future passengers and crew about an outbreak on the previous voyage. Several improvements had been made to the OPRP since the last inspection.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
Item No.: 41
Site: Housekeeping-Public Toilet Room
Violation: The public toilet room on the lounge deck did not have a sign advising passengers to wash their hands. Also, there was no sign advising users of toilet facilities to use a hand towel, paper towel, or tissue to open the door.
Recommendation: Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 43
Site: Ventilation-Construction
Violation: The air handling unit condensate drain pans and collection systems were not able to be easily accessed for inspection, maintenance, and cleaning.
Recommendation: Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
Item No.: 19
Site: Other-Beverage Storage Areas - Forward PW Tank Room & Bow Thruster Room
Violation: Food items were stored in these rooms and the deck was made of vinyl linoleum that was not constructed or maintained for easy cleaning. This was noted on the previous inspection, but many improvements were made to this area since the last inspection.
Recommendation: Do not store foods: (1) In locker rooms; (2) In toilet rooms; (3) In dressing rooms; (4) In garbage rooms; (5) In mechanical rooms; (6) Under sewer lines that are not continuously sleeve welded; (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; (8) Under open stairwells; (9) Under other sources of contamination from nonfood items such as ice blocks, ice carvings and flowers; or (10) In areas not finished in accordance with 7.7.4 and 7.7.5 for food storage areas.
Item No.: 06
Site: Potable Water-Monthly Microbiological Sampling
Violation: One of the four July representative water samples included a sample drawn from the water dispenser on the soda gun at the bar. This sample location is not a true representation of the water supply system.
Recommendation: Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program