Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 12/06/2013 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 37
Site: Galley-Hot Line
Violation: There was excess heat in the worker area in front of the hot line with the stove top and fryers. Workers in the area were sweating excessively and their hats were wet with sweat. The inspector measured the ambient temperature of the area to be at least 85°F. The exhaust system was turned up.
Recommendation: Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 33
Site: Galley-Clean Storage
Violation: A cork bulletin board was attached to the bulkhead on the back of the clean storage unit and was soiled with dirt and food debris in the outer edges of the frame. Also, the frame had difficult to clean surfaces and a few pieces of cork were coming off the board, making it difficult to clean.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 27
Site: Pantry-Wine Cellar Deck 7
Violation: There was excess black debris in a few areas on the white drainage panel in the middle compartment of the ice machine.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Galley-Handwashing Station
Violation: There was less than 220 lux of light intensity at the handwashing station in the entrance of the port galley.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 19
Site: Buffet-Deck 7 Terraza
Violation: There were two trays of bread that were not fully protected under the sneeze guard at the left entrance of the buffet.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 36
Site: Buffet-Deck 7 Terraza
Violation: The light intensity was less than 220 lux at the most right front and back counters on the worker side of the buffet.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Buffet-Deck 7 Terraza
Violation: There was a heavy amount of dirt and dust debris on the deckhead between the plenum spaces and the bulkhead at the far right of the worker side of the counter between the front and back counters. This was written on the last inspection.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 36
Site: Buffet-Deck 7 Terraza
Violation: The light intensity was less than 220 lux at the handwashing sink to the right of the ice machine and in front of the ice machine and less than 110 lux behind the ice machine.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 33
Site: Other-Panorama Food/Equipment Cabinet
Violation: There was a long line of brown residue on the bulkhead from the top of the food and equipment storage cabinet to the deck. The deck below the cabinet was also soiled with a brown residue and there were several pieces of food debris along the deck/bulkhead juncture, especially in the corners. Also, the coving at the deck/bulkhead juncture was missing or recessed.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Other-Panorama Equipment Locker
Violation: Several trays of clean glasses and waiter trays were stored on galvanized shelving that was worn and chipped in several areas.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 36
Site: Other-Panorama Equipment Locker
Violation: The light intensity was less than 220 lux where several trays of clean glasses and waiter trays were stored.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 27
Site: Pantry-Panorama
Violation: There was a large amount of brown residue on the white tray used for draining the ice in the middle compartment of the ice machine.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Pantry-Panorama
Violation: The time control plan for the bar area stated the set-up and discard times for the food on time control, but it also stated the food would be on temperature control from 37°F to 40°F. This was corrected.
Recommendation: Ensure the food is either on time or temperature control and update the time control plan to describe the food service operation.
Item No.: 33
Site: Bar-Panorama
Violation: The coving on the worker's side of the bar was missing or recessed at the deck/counter juncture. Also, the back bulkhead was covered in wallpaper that was torn in a few areas and soiled in several areas. Finally, there was a large gap between the back bulkhead and deckhead and large open holes could be seen in the deckhead through the gap.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 16
Site: Room Service-Breakfast Menu
Violation: All of the food items of animal origin that were served raw or undercooked were identified with an asterisk, but the consumer advisory was printed on the back of the menu where there were no food items indicated.
Recommendation: Ensure the consumer advisory statement is indicated on the menu where the food items of animal origin that are served raw or undercooked are identified.
Item No.: 24
Site: Galley-Cold Pantry
Violation: There was less than 50 ppm chlorine in the bucket of sanitizing solution near the cleaning locker.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 20
Site: Galley-Hot Line and Bakery
Violation: There were several slotted fasteners in the food-splash zones of the two wire whisks near the hot line and in the bakery.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 30
Site: Food Service General-Food Worker Toilets
Violation: There were no signs indicating 'wash hands after using the toilet' in the food worker toilets in the main and crew galleys.
Recommendation: Ensure signs are conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand.
Item No.: 41
Site: Galley-Food Worker Toilets
Violation: There was no sign advising users to use a paper towel or tissue to open the door in the female food worker toilet.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 33
Site: Buffet-Crew Mess
Violation: There was no coving at the cabinet/deck juncture of the self-service bread station.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 20
Site: Buffet-Officer Mess
Violation: There were two slotted fasteners in the food-splash zone of the juice machine on the beverage station.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Galley-Dining Room Breakfast Menu
Violation: The first menu given to the inspector did not identify the foods of animal origin cooked to order or served undercooked, including eggs cooked to order and poached eggs, but there was a consumer advisory statement on the menu. The second menu given to the inspector did have all of the requirements for the foods of animal origin cooked to order or served undercooked.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 22
Site: Galley-Warewashing
Violation: The data plate on the in-use conveyor warewash machine indicated the minimum pressure for the final rinse should be 20 psi, but during several washing and sanitizing cycles, the pressure was always less than 10 psi.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 36
Site: Other-Panorama Food/Equipment Cabinet
Violation: The light intensity where the food and equipment was stored was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Bar-Panorama
Violation: There was a large gap in the deck at the door threshold and there was a heavy amount of corrosion along the entire door threshold.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are corrosion resistant. Close the gap in the deck at the door threshold.
Item No.: 39
Site: Bar-Panorama
Violation: There were two live fruit flies on the back bar bulkhead. This area was not in-use during the inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 21
Site: Galley-Port Locker
Violation: Several bottles of liquor, cans of beer and equipment such as tongs, aluminum foil, and packages of baking liners and doilies were stored on a shelving unit that was corroded and worn in several areas.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 37
Site: Galley-Port Warewashing
Violation: There was excess condensation that had collected on the bulkhead and deckhead above the in-use conveyor warewash machine and the condensation was dripping back onto the machine. No clean items were impacted.
Recommendation: Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 20
Site: Buffet-Crew Mess
Violation: There were two slotted fasteners in the food-splash zone of the juice machine on the beverage station.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Galley-Cold Pantry
Violation: The ready to eat potato salad had a label indicating the production date was December 5, but according to the cooling logs, the cooked potatoes, which were the first ingredient, were cooked on December 4. The potato salad was labeled with a discard date of December 11.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1.
Item No.: 33
Site: Food Service General-Grouting
Violation: There was missing or recessed deck tile grouting in several food areas including, the main galley hot lines, pot wash, panorama pantry, pool grill, and all warewashing areas. This was noted on the last inspection. A dry dock action plan list indicated that grouting would be done in all galleys and in the pool bar area during the upcoming December dry dock.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 24
Site: Galley-Pot Wash
Violation: A worker was observed sanitizing a small condiment pan for less than seven seconds in a chlorine solution. The worker was corrected by the food manager in this area.
Recommendation: Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 22
Site: Other-Clean and Soiled Storage
Violation: There were large closed upright trolleys stored on the deck 6, 7, 8 and 9 crew staircases labeled 'bravo' that contained several trays of soiled dishes, equipment and food items from the cabins. According to staff, they do not have enough soiled or clean storage in the pantries to store everything needed for the butler service the ship started offering in 2009. The soiled trays used by the deck stewards did not fit in the soiled storage shelving units in the pantries. Also, there were no clean storage shelves in the pantries. According to staff, the clean equipment and utensils are stored on top of and around the utility sinks next to the ice machines. Also according to staff, the utility sinks were not needed for the operation. The soiled trolleys were found in these areas during the morning hours of the inspection and were still in the crew passageways at 1530. There were 158 suites that could obtain butler service.
Recommendation: Ensure soiled equipment and utensils are not stored in staircases and provide sufficient space for the storing of all clean and soiled items needed for the operation.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Surveillance Log
Violation: The case Identification number column was not completed for any of the AGE surveillance logs. Since the last inspection, some voyages had between one and three reportable AGE cases listed on the AGE logs.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (3) case identification number.
Item No.: 19
Site: Pantry-Medical Center
Violation: A box of bottled water was stored on the deck.
Recommendation: Protect food from contamination by storing the food: (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: Since the last inspection, six potable water tanks were disinfected. The records indicated the tanks had a residual halogen level of less than five ppm before being put back into service, however the actual chlorine level was not documented.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Main Laundry FSD AO 2.4
Violation: On the port potable water line, after the reduced pressure assembly, some of the white paint had chipped off, exposing a blue color indicating potable water.
Recommendation: Do not stripe or paint potable water lines after reduced pressure assemblies as potable water.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The OPRP was missing information regarding the concentrations and contact times of the disinfectant used during red level. For example, in section 10 (Rooms: Divisions and Guest Relations - Turnaround Day), section 12 (Concessions: Beauty Salon, Spa, Gym, Boutique, Casino), and section 13 (Internet Cafe and Library) the plan stated to use 1000 ppm chlorine solution, but there was no contact time specified. Also, the plan stated the all-purpose antibacterial disinfectant could be used as an alternative, but there was no concentration or contact time indicated for this product.
Recommendation: Update the OPRP to reflect the manufacturer's recommendations for the concentration and contact time of the all-purpose disinfectant and the contact time for the chlorine solution.
Item No.: 43
Site: Housekeeping-Shower Head Disinfection - Medical Center
Violation: There was no documentation that the shower heads in the medical center were cleaned and disinfected.
Recommendation: Clean and disinfect shower heads every 6 months. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
Item No.: 40
Site: Integrated Pest Management-Incoming Supplies
Violation: There was no documentation that all supplies brought onboard were inspected for pests, such as flowers, plants, and engineering supplies.
Recommendation: Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
Item No.: 39
Site: Provisions-Wine/Water Room
Violation: One live fly was in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Preparation Room-Entrance
Violation: The locking mechanism was missing in the entrance door, exposing a hole.
Recommendation: Replace the locking mechanism or close the hole.
Item No.: 36
Site: Preparation Room-Handwash Station
Violation: The light intensity was less than 220 lux at the handwash station.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 20
Site: Buffet-Panorama Food Display
Violation: The food equipment display case used for breakfast items on time control had several difficult to clean interior features and there were several slotted fasteners inside the unit. This unit was not in-use during the inspection.
Recommendation: Ensure food-contact surfaces of food equipment complies with American National Standards Institute (ANSI), National Sanitation Foundation International (NSF International), or other internationally accredited food equipment sanitation standards for materials, design, and construction. Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 36
Site: Galley-Hot Line
Violation: There were two lights above the hot line and there were a few small cracks in each light directly over cooking equipment.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program