Cruise Ship: Island Princess Cruise Line: Princess Cruises Inspection Date: 12/21/2013 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Records
Violation: The electronic master gastrointestinal (GI) illness log was designed to transfer information required to be recorded in the standardized AGE surveillance log automatically. In the data field called 'Comments,' the master GI log included underlying illness as well as many comments related to the ill persons' meals, drinks, or activities ashore. This comment field data was automatically transferred to the required standardized AGE surveillance log under the field called underlying illness. In most of the individuals there was no answer provided in the underlying illness field, but these activity and meals comments were inserted. Additionally, where there were no underlying medical conditions there were a number of entries stating 'None, AGE.'
Recommendation: Ensure that the medical staff understand that in completing the master GI illness log that the underlying illness question should be answered first, so when the data transfers down to the official surveillance log the specific question is answered. Staff should also understand that the underlying illness is referring to a pre-existing medical condition which may in some way contribute to the symptoms of the case patient, and is not meant to be a field to enter the current illness diagnosis of AGE.
Item No.: 08
Site: Potable Water-Backflow Prevention - Listing
Violation: In the listing of non-testable backflow prevention devices the acronym PVB was written for nearly every device under the column titled device type. In the few other device types listed the acronym SVB was written. PVB stands for pressure vacuum breaker, which is a device type, but none of the specific models listed was a PVB. Many were atmospheric vacuum breakers (AVB), continuous pressure (CP) backflow preventers, or non-continuous pressure (NCP) backflow preventers.
Recommendation: The entire non-testable backflow preventer list should be reviewed and the device type should be accurate for each device used.
Item No.: 16
Site: Galley-Bell Box
Violation: The time control plan for this area listed the reach-in refrigerator as on time control from 6AM-10AM only, and the rest of the time on temperature control.
Recommendation: Refrigeration and hot-holding units must be designated either under time control or temperature control.
Item No.: 16
Site: Buffet-Bain Marie Hot Cabinet
Violation: Three stacked trays of cooked fish were on time control but only one discard label was provided. The time control plan for the area indicated the crew mess service period was longer than 4 hours.
Recommendation: Each individual tray of cooked fish in hot holding must be labeled with a discard time since the service period is longer than 4 hours.
Item No.: 16
Site: Galley-Horizon Court
Violation: A loose bag of skim milk was sitting on top of the cardboard milk container in the bulk milk dispensing unit. This bag was half-empty and did not have a 7 day discard label.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 17
Site: Galley-Deck 12 Horizon Court Galley
Violation: A container of coleslaw was placed in the blast chiller at 8AM at a temperature of 48°F according to the cooling log. The inspector arrived at 9AM and took a temperature of the coleslaw which was at 51°F. The inspector and staff calibrated their thermometers in an ice bath. The staff member's bi-metallic stem thermometer that was used for the intial temperature read 20°F in the ice bath. The thermometer was immediately calibrated and the coleslaw was cooled to 41°F within 4 hours.
Recommendation: Ensure a calibrated thermometer is used to accurately measure food temperatures during the cooling process.
Item No.: 20
Site: Galley-Deck 12 Horizon Court
Violation: A container of coleslaw was placed in the blast chiller at 8AM at a temperature of 48°F according to the cooling log. The inspector arrived at 9AM and took a temperature of the coleslaw which was at 51°F. The inspector and staff calibrated their thermometers in an ice bath. The staff member's bi-metallic stem thermometer that was used for the initial temperature read 20°F in the ice bath. The thermometer was immediately calibrated and the coleslaw was cooled to 41°F within 4 hours.
Recommendation: Ensure food temperature measuring devices: (1) scaled only in Celsius or dually scaled in Celsius and Fahrenheit are accurate to within1°C (within 2°F) in the intended range of use; (2) scaled only in Fahrenheit are accurate to within 2°F in the intended range of use. Ensure food temperature measuring devices have a numerical scale, printed record, or digital readout in increments no greater than 1°C (2°F) in the intended range of use.
Item No.: 23
Site: Galley-Deck 14 Horizon Court Mechanical Dishwash
Violation: The data plate on the in-use flight type mechanical dishwasher stated a minimum wash temperature of 160°F. When tested by the inspector the wash temperature measured 149°F.
Recommendation: Ensure the wash temperature meets the manufacturer's recommendation.
Item No.: 26
Site: Buffet-Crew Mess Beverage Station
Violation: A black and brown residue was accumulating around the black screw cap directly under the ice dispensing chute of the counter ice/water machine.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Deck 6 Garde Manger
Violation: The recessed ledge on the back plate of the previously cleaned deli slicer was soiled with food residue.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 29
Site: Galley-Deck 5 Toilet Room
Violation: The door to the toilet room was locked during the inspection and the galley was in full operation.
Recommendation: Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
Item No.: 29
Site: Galley-Sabitini's Toilet Room
Violation: The crew toilet room was out of service during the inspection. A sign on the door stated 'spare parts were ordered.' Staff did not know how long the toilet room had been out of order and no documentation on the status could be provided to the inspector. The toilet room was fixed and operational by the end of the inspection.
Recommendation: Ensure toilet rooms are provided and conveniently located.
Item No.: 33
Site: Provisions-Dairy Walk-In
Violation: A light fixture in the far right corner of the room was filled with water and dirt debris. All the water was contained in the fixture and no food was impacted.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Deck 6 and 5
Violation: Several areas of Deck 6 and 5 main galley had cracked tiles and missing grouting. Specific areas include around most of the scupper drains, Deck 6 pastry in front of ice cream station, and in front of the elevator on Deck 5.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Bayou Cafe
Violation: Large sections of grouting was missing in front of the grills and in front of the undercounter cabinets opposite of the grills.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Buffet-Horizon Court Beverage Station
Violation: Dried coffee or ice tea residue was on the far bulkhead in the technical compartment under the coffee and ice tea station.
Recommendation: Clean spills immediately and maintain the bulkhead in a clean condition.
Item No.: 33
Site: Buffet-Horizon Court Port Gazebo Hot Line
Violation: The exhaust vent above the buffet line was not flush against the deckhead creating a gap which allowed dust to accumulate.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Buffet-Horizon Court Starboard Gazebo Hot Line
Violation: Several deck tiles were cracked and grouting was missing in this area.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Pizzeria Show Galley
Violation: Several sections of grouting was missing in the coving under the cabinets and against the bulkhead.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Deck 12 Horizon Court Soup Station
Violation: Grouting was missing in several areas, including: in front of the soup kettles, to the left of the soup kettles by the coving against the bulkhead, and around the center preparation table. Standing water was present in several of the missing grout grooves.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Deck 12 Horizon Court Soup Station
Violation: The bulkhead seam to the left of the soup kettles was missing about 12 inches of sealant on the bottom of the seam near the deck juncture.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 41
Site: Galley-Deck 5 Toilet Room
Violation: No sign was posted advising users to use a paper towel to open the bathroom door upon exiting,
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 44
Site: Recreational Water Facilities-Lotus Pool
Violation: There was a significant limb entrapment hazard presented by two large openings in a cover panel for the wave machine attached at the one end of the pool. The panel lower corner was separated from the pool wall at a level approximately 1 meter below the pool water surface. Additionally, a center metal grid for the same panel was separated from the surface of the panel. There was a white tube passing from the gap in the lower edge of the panel to the floor of the pool. Staff stated that rough seas on the previous cruise caused the damage. Ensure that no children enter this pool until these entrapment hazards are completely corrected.
Recommendation: Ensure that all parts of the wave machine's cover panel, attached grid, and tubing are repaired or replaced so the pieces are tight to the pool wall and all components are retained inside the panel tightly as designed. As the gap present at the pool wall and around the metal grid of the panel are large enough for a child's hand or foot to fit in and both occur well below the water surface, ensure that children are not allowed to use the pool until this issue is completely repaired. Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory