Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Surveillance Log
|
|
Violation:
Not all cases on the AGE log received a case identification number. During the December 23, 2013 - January 4, 2014 cruise, a reportable passenger was on the AGE log with a 'N/A' case identification number. Also, there were several passengers on the AGE log for the November 29 - December 23, 2013 cruise with 'N/A' case identification numbers. There were specific case identification numbers written on the AGE log for crew members. Finally, there was a crew member who was identified as an assistant butcher on the medical staff's notes, but the crew position on the AGE log was indicated as 'N/A'.
|
|
Recommendation:
Ensure the AGE surveillance log entry for each passenger or crew member contain: (3) case identification number; (8) crew member position or job on the vessel, if applicable.
|
|
|
Item No.:
02
|
|
Site:
Medical-Crew Contacts
|
|
Violation:
The times of the interviews conducted on the close contact of the crew member who became ill on December 2 at 0300 were not recorded. There were interviews conducted with this close contact on three separate occasions.
|
|
Recommendation:
Maintain the following records on board for 12 months and make them available for review by VSP during inspections and outbreak investigations: (7) documentation of the date and time of verbal interviews with asymptomatic cabin mates and immediate contacts of symptomatic crew.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Microbiologic Monitoring
|
|
Violation:
A monthly water sample was taken in the spa treatment room, but there was no information on what part of the ship this room was located and according to staff there was more than one spa treatment room.
|
|
Recommendation:
Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result. Include detailed information on the locations where water is sampled.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Turnover Rates
|
|
Violation:
Each whirlpool had a turnover rate of 1.1 hours and not 0.5 hour as required.
|
|
Recommendation:
Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (5) whirlpool spa: 0.5 hours.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Plan - For PHF Beverages
|
|
Violation:
The milk time control plans for the crew mess, staff mess, and the 6 bars had a set-up time of 0500 and a discard time of 0200, stated 'food discarded according to label', but were not specific as if the food was to be discarded according to individual 4-hour discard labels. The plans also were not specific as to the locations of the milk on time control. The set-up and discard times of these generic plans did not match the times of operations of the outlets. Also, the staff stated that milk was not held in the crew bar but there was a milk time control plan.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The time control plan indicated Bouillon Service was 10am - 11:30am. There was a statement of 'no units assigned' as designated time control units. According to the staff, the end of the counter-top (and occasionally individual tables) were designated as the areas where potentially hazardous foods were placed during this service, but these were not identified on the plan.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Plans
|
|
Violation:
Generic time control plans were posted in the bars and lounges on decks 4, 5, 6, 7, 10, and 11. Some of these plans, such as the Casino Bar, indicated that canapés were placed on time control, but staff explained that canapés were not provided at all bars and lounges.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Other-Deck 6 Card Room
|
|
Violation:
The milk chiller used for milk on time control was not indicated on the time control plan and was not labeled as a time control unit.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Dining Room-Compass Rose Breakfast Menu
|
|
Violation:
The egg dishes that were cooked to order had a very faint and small asterisk that was barely visible. There was a consumer advisory on the menu.
|
|
Recommendation:
Identify the cook to order egg dishes with a more visible asterisk.
|
|
|
Item No.:
16
|
|
Site:
Galley-Room Service
|
|
Violation:
There were four containers of heavy cream, soy milk, regular milk, and skim milk that were labeled with time control discard times of 10:15 PM, but these items were not indicated on the time control plan. The time control plan only included the breakfast service from 6:00 to 11:00 AM.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
17
|
|
Site:
Galley-Walk-In Cooler #57
|
|
Violation:
The cooling times and temperatures of a hotel pan of cut cabbage dated 16 January, a tray of cut tomato dated 15 January, and another tray of cut tomato dated 16 January were not documented in a cooling log.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Fish Thawing Room
|
|
Violation:
There was a hotel pan with 4 lobster tails that was uncovered and unprotected. This was corrected.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected.
|
|
|
Item No.:
19
|
|
Site:
Other-24-Hour Coffee Station
|
|
Violation:
Plates out for passenger self-service were stored upright and not inverted or covered. The crew member assigned to the area immediately inverted the plates.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
20
|
|
Site:
Buffet-Officer's Mess
|
|
Violation:
Two slotted fasteners were on the back side of the food-splash zone of the espresso machine.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones.
|
|
|
Item No.:
21
|
|
Site:
Pantry-Deck 5 Pantry
|
|
Violation:
There was peeling sealant along the length of the gap between the right panel of the ice machine and the splash panel next to the utility sink.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewashing
|
|
Violation:
The temperature gauges of the conveyor warewash machine for the pre-wash tank, wash tank, and final rinse had a film over the glass and the temperatures were difficult to read.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
28
|
|
Site:
Dining Room-Forward Waiter Stations
|
|
Violation:
At the entrance to the main galley, there were four clean glasses on the right waiter station and eight clean glasses on the left waiter station that were stored upright and not covered or inverted.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Dining Room-Compass Rose Waiter Station #14
|
|
Violation:
There were two stacks of clean plates that were stored on this station and were not covered or inverted.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Pantry-Galileo's Lounge
|
|
Violation:
A basket of previously cleaned silverware was stored on the side of the utility sink. Staff stated the overshelf above the utility sink was clean storage. The silverware was moved to the overshelf.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Bar-Galileo's Lounge
|
|
Violation:
Inside the second cabinet below the first marble counter, a previously cleaned chafing dish was stored wet with standing water.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Galley-Silver Locker Deck 5
|
|
Violation:
The top rack of clean equipment had several pitchers and serving containers that were not all stored covered or inverted.
|
|
Recommendation:
Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
28
|
|
Site:
Galley-Warewashing
|
|
Violation:
Several stacks of clean plates were stored under a deckhead full of condensation. No condensation was seen dripping onto the plates.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Poultry Walk-In Freezer
|
|
Violation:
There was sealant around the deckhead hatches, but some missing silicone created gaps that were difficult to clean.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Preparation Room-Fish
|
|
Violation:
The deck in front of the fish preparation room was in disrepair.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Store
|
|
Violation:
There was a gap on the deckhead next to the center light fixture.
|
|
Recommendation:
Close the gap.
|
|
|
Item No.:
33
|
|
Site:
Other-Deck 6 Card Room
|
|
Violation:
There was no coving at the counter/deck juncture of the waiter station with food and clean equipment. Also, the deck was carpeted and there were brown stains in a few areas in front of the station.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Dining Room-Starboard Waiter Station Compass Rose
|
|
Violation:
There were holes to the plenum spaces above the clean waiter station at the entrance to the galley. Clean glasses and condiments were stored on this waiter station. Also, there was no coving at the counter/deck juncture.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Other-Main Galley Restaurant Locker
|
|
Violation:
There were at least 20 sets of chop sticks, plates, paper cups, plastic utensil sets, at least five serving trays, and eight condiment holders in this room that was not constructed for food equipment and utensil storage. For example, there was no coving at the bulkhead/deck juncture and there was wall paper that was torn in a few areas on the bulkhead.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Galley-Hot Line
|
|
Violation:
The light intensity was less than 110 lux to the left of the microwave.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Other-Main Galley Restaurant Locker
|
|
Violation:
The light intensity was less than 220 lux where clean equipment was stored.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
37
|
|
Site:
Galley-Warewashing
|
|
Violation:
There was excess condensation on the deckheads and bulkheads on the soiled and clean ends of the conveyor warewash machine. Also, there was excess condensation on the deckhead over a table with several stacks of clean plates. No condensation was seen dripping onto the plates.
|
|
Recommendation:
Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
37
|
|
Site:
Galley-Hot Line
|
|
Violation:
Near the salamander, there was a condensate leak from the deckhead hatch. The condensation was dripping onto the deck. No food or clean items were impacted.
|
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
37
|
|
Site:
Provisions-Poultry Walk-In Freezer
|
|
Violation:
There was a continuous condensate leak from the deckhead at the center of the freezer. The condensation was dripping onto the deck. No food appeared to be impacted.
|
|
Recommendation:
Repair the leak.
|
|
|
Item No.:
37
|
|
Site:
Galley-Near Entrance
|
|
Violation:
Near the handwashing sink at the entrance, there was a continuous condensate leak from the deckhead hatch. The condensation was dripping onto the deck. Staff stated the leak was due to the air conditioning duct.
|
|
Recommendation:
Repair the leak.
|
|
|
Item No.:
37
|
|
Site:
Galley-Dishwash Area
|
|
Violation:
Above the soiled end of the dishwash machine, there was a continuous condensate leak from the deckhead hatch. The condensation was dripping onto the machine.
|
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
38
|
|
Site:
Food Service General-Cleaning Lockers
|
|
Violation:
In all of the galleys, bar pantries, and housekeeping pantries, the cleaning lockers were labeled 'Cleaning Locker' and not 'Cleaning Materials Only' as required.
|
|
Recommendation:
Label the locker "CLEANING MATERIALS ONLY."
|
|
|
Item No.:
39
|
|
Site:
Pantry-Galileo's Lounge
|
|
Violation:
There was a fly in the pantry. The area was in operation during the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Preparation Room-
|
|
Violation:
There was a fly over the handwashing sink. The area was in operation during the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
41
|
|
Site:
Medical-Crew Isolation Ward
|
|
Violation:
There were shared cloth towels at the handwashing sink in the public toilet room. On the back of the exit door, there was a dispenser of small thin tissues that would not be able to dry someone's hands.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. Ensure that the method provided to dry hands is sanitary and effective.
|
|