|
|
|
Item No.:
16
|
|
Site:
Dining Room-Quantum
|
|
Violation:
A coffee and tea setup included containers of cream and milk which were kept on time control, but there was no time control plan nor were the products labeled with a discard time. Staff stated that this is only setup during port visits.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Menus Consumer Advisory
|
|
Violation:
The consumer advisory statement on the menus for all the different food outlets, including in-room dining, did not include the phrase, 'especially if you have certain medical conditions'.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Consumer Advisory
|
|
Violation:
The consumer advisory at the buffet for the cold smoked salmon was not located where the salmon was being offered nor was the advisory specific to the salmon. Also, the advisory statement did not have the phrase, 'especially if you have certain medical conditions'.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served.
|
|
|
Item No.:
19
|
|
Site:
Buffet-
|
|
Violation:
Service tongs used by staff to serve passengers at the buffet were not located under the sneeze shield or protected from potential contamination by other means. According to staff, the food is served by the crew members, however, the distance between where passengers stand to request the food and where the utensils are located is less than 1 meter.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Lights
|
|
Violation:
Ten heating lamp light bulbs located above the food display at the right side of the buffet were not shielded, coated, or shatter-resistant.
|
|
Recommendation:
Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
|
Item No.:
16
|
|
Site:
Galley-Omelet Station
|
|
Violation:
Three working hotel containers of different omelet ingredients placed on the preparation counters were not labeled with discard time labels. A discard label was affixed to the bulkhead behind the working containers but the containers were not physically labeled. The posted time control plan for the area instructs working containers of food to be physically labeled.
|
|
Recommendation:
Containers of POTENTIALLY HAZARDOUS FOOD under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours..
|
|
|
Item No.:
44
|
|
Site:
Food Service General-Vacuum Packaging
|
|
Violation:
The ship was using vacuum packaging to hermetically seal containers of cooked osso bucco. According to staff, the osso bucco was cooked, cooled, and then vacuum packaged and sealed for later use. These products were observed in a under counter reach in cooler in the buffet galley and in a large provision freezer. Staff, stated that they remove the food items from the plastic seal prior to cooking and that osso bucco is the only food item that is re-packaged this way.
|
|
Recommendation:
12.13.3.3 Areas Not Identified (44)
Procedures, systems, equipment, technology, processes, or activities that are not identified in the scope of this manual must not be tested or introduced operationally onboard any vessel until the concept is submitted in writing to the VSP Chief for review. If the review determines the concept is within the scope of the VSP Operations Manual, written procedures, control measures, or a complete variance submission may be required.
|
|
|
Item No.:
15
|
|
Site:
Food Service General-Vacuum Packaging
|
|
Violation:
The ship was using vacuum packaging to hermetically seal containers of cooked osso bucco. According to staff, the osso bucco was cooked, cooled, and then vacuum packaged and sealed for later use. These products were observed in a under counter reach in cooler in the buffet galley and in a large provision freezer. Staff, stated that they remove the food items from the plastic seal prior to cooking and that osso bucco is the only food item that is re-packaged this way.
|
|
Recommendation:
Ensure food in a hermetically sealed container is obtained from a food-processing plant that is regulated by the food regulatory agency that has jurisdiction over the plant.
|
|
|
Item No.:
26
|
|
Site:
Galley-Ice Machine
|
|
Violation:
A build-up of black granular sediment was observed in the plastic water return tray.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pastry
|
|
Violation:
Two slotted fasteners were on the mixing arm located in the food splash zone to the counter mounted mixer. One of the fasteners was soiled with old white food residue.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
26
|
|
Site:
Galley-Pastry
|
|
Violation:
One of the slotted fasteners was soiled with old white food residue on the previously cleaned counter mounted mixer as mentioned in the previous violation.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
16
|
|
Site:
Galley-Reach in Cooler #15
|
|
Violation:
A cut of cooked lamb was located in this refrigerator without a seven day discard label.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The data plate for the rack-type conveyor dishwash machine listed a conveyor speed in racks per hour rather than a minimum transit time.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Mixer
|
|
Violation:
Two slotted fasteners were on the mixing arm located in the food splash zone to the counter mounted mixer.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Regatta
|
|
Violation:
Light intensity at the clean glass storage racks was less than required 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Spa Whirlpool
|
|
Violation:
The safety signage for the whirlpool was located on the wall adjacent to the entrance into the spa room and not at the entry point for the spa.
|
|
Recommendation:
In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
|
|
|
Item No.:
*
|
|
Site:
Food Service General-Recreational Fishing Variance
|
|
Violation:
A recreational fishing variance has been prepared by the ship which would allow passengers to bring caught fish back to the ship to be prepared by galley staff. The policy has yet to be received and approved by VSP. According to staff, no passengers have participated in this activity since the prior inspection.
|
|
Recommendation:
Submit written variance to VSP if ship plans to allow this activity.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Medical - Microbiological Monitoring
|
|
Violation:
The medical staff collected water samples from the same exact locations each month for microbiological analysis. There were not 4 random samples collected from the potable water distribution system.
|
|
Recommendation:
Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Medical Center ICU and Isolation Ward
|
|
Violation:
The public toilets in the medical center did not have signs at the handwash station advising handwashing. Staff placed signs in both the isolation ward room toilet and the ICU room toilet during the inspection.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Tank Maintenance
|
|
Violation:
The written record for the July 2013 painting of potable water tank 9 port did not include a statement that the paint was applied according to the manufacturer's instructions.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Pool and Whirlpool Spa Maintenance
|
|
Violation:
The electronic records for the pool and whirlpool spa maintenance specified the weekly cleaning and disinfection of the hair and lint strainer in job
# CL080, but there was no separate record for the cleaning and disinfection of the hair and lint strainer housing. Staff stated that they do clean and disinfect the strainer housings when they do this job for the strainers.
|
|
Recommendation:
Update the job description in the electronic system so it captures both the hair and lint strainer and the housing in the job procedure.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Medical Center ICU and Isolation Ward
|
|
Violation:
The October 2012 revised written OPRP specifies the use of the HP Alpha cleaner/disinfectant throughout the plan as the product for hard and soft surface disinfection. Staff stated that there is still some of this product remaining on the ship which is used for fogging when needed, however, the product being used throughout the ship is Oxivir TB. There was no mention of this product in the written OPRP.
|
|
Recommendation:
Update the written outbreak prevention and response plan to describe the disinfectant product used, on what surfaces, and what the concentration and contact time should be for it.
|
|