Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seabourn Quest Cruise Line: Seabourn Cruise Line Inspection Date: 03/22/2014 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: The number of reportable passengers and reportable crew members listed on the AGE log did not match the submitted 4-hour report. The AGE log listed 2 reportable passengers and 3 reportable crew members and the 4-hour report listed 2 reportable passengers and 4 reportable crew members. After further investigation it was determined the 4-hour report contained the correct information.
Recommendation: Ensure the AGE log contains accurate information.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: A crew member reported to medical with 2 episodes of diarrhea on 14 March. No underlying illness was noted and anti-diarrhea medication was dispensed. Documentation showed this was not above normal for the individual but the crew member was still listed as reportable on the AGE log.
Recommendation: Ensure nonreportable case are not listed as reportable cases on the AGE log.
Item No.: 11
Site: Medical-Late Crew Reporting
Violation: A band member deemed a reportable case by medical staff experienced illness onset on 4 March at 1600, but did not report to medical until 5 March at 0915. Work timesheets showed the band member worked the evening of 5 March.
Recommendation: Ensure crew members immediately report to medical after onset of AGE symptoms.
Item No.: 22
Site: Pantry-Pantry 6
Violation: Water was leaking from the undercounter dishwash machine.
Recommendation: Ensure water does not leak from the undercounter dishwash machine.
Item No.: 33
Site: Pantry-Pantry 6
Violation: A significant amount of water was pooled on the deck along the bulkhead to the left of the undercounter dishwash machine.
Recommendation: Ensure water is not allowed to accumulate and pool on the deck.
Item No.: 26
Site: Pantry-Pantry 6 Ice Machine
Violation: The interior side of the white deflector panel had black residue on the bottom in and around the recessed ledge.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 08
Site: Potable Water-Permeate Water Pipe Striping
Violation: The permeate water lines from both reverse osmosis units where not striped blue/gray/blue up to the chlorine injection point.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 08
Site: Potable Water-Cross Connection Control Plan
Violation: The air gap for the high salinity discharge from the mineralizer to the condensate tank was not listed on the vessel's plan.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Potable Water-Potable Water Tank Maintenance Records
Violation: The narrative summary inspection report for four of the five potable water tanks from May 2013 stated painting was applied but did not state if the paint was applied, dried, and cured according to the manufacturer's recommendation.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
Item No.: 08
Site: Potable Water-Secondary Certification Documenation
Violation: No paperwork was available from a third party organization to verify the paint on the interior of the potable water tanks was approved for potable water contact.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
Item No.: 08
Site: Potable Water-Production Records
Violation: The chlorine residue level from production on 17 March did not reach 2 ppm within 30 minutes of starting production. Production via reverse osmosis started at 18:20 and reached 2 ppm at 19:53.
Recommendation: Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
Item No.: 09
Site: Recreational Water Facilities-Deck 8 Starboard Spa
Violation: The pH level was measured at 7.95 by the inspector and 7.98 and 7.95 by the crew member. The spa was open at the time of the inspection and was immediately closed.
Recommendation: Maintain the pH level in all RWFs between 7.0 and 7.8. Immediately close facilities if these halogen and pH ranges are not maintained.
Item No.: 19
Site: Buffet-Colonnade - Bread Line
Violation: Two platters of bread items for passenger self-service were on both sides of the toaster, but a serving utensil was only available for the platters to the right of the toaster.
Recommendation: Ensure consumer self-service operations, such as salad bars and buffets, for unpackaged ready-to-eat foods are provided with suitable utensils or effective dispensing methods that protect the food from contamination and are monitored by food employees trained in safe operating procedures.
Item No.: 22
Site: Galley-Colonnade - Dishwash Machine
Violation: During operation, the wash tank was soiled with food debris, sugar packets, and pieces of paper towels.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 21
Site: Galley-Colonnade - Beverage Station
Violation: On the WMF coffee machine, the water line plastic coating was torn in some areas, making cleaning difficult.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Other-Patio Grill
Violation: The coving around some of the deck drain coamings was missing or in poor condition.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 36
Site: Other-Patio Grill
Violation: The left light cover was missing inside the lower pizza oven shelf.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 33
Site: Other-Patio Grill
Violation: To the right of the deep fat fryer, the sealant was missing between the lower decorative bulkhead and the top of the deck/bulkhead coving tiles. Sealant was also missing below the adjacent handwash station between the lower stainless steel bulkhead and the top of the deck/bulkhead coving tiles.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 36
Site: Dining Room-Waiter Stations
Violation: The light intensity could not be raised to 220 lux at all areas of the clean waiter stations.
Recommendation: In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 22
Site: Galley-Starboard Dishwash
Violation: On the dishwash machine, the electrical control panel showed a red alarm display. Crew members in the area continued to send dishes through the machine. The control panel stated there was an error with the final rinse water flow. A visual inspection of the final rinse nozzles did not indicate an unusual flow pressure.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 21
Site: Galley-Port Beverage Station
Violation: On the coffee machine, the water line plastic coating was torn in some areas, making cleaning difficult.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 20
Site: Galley-Port Beverage Station
Violation: Inside the silver storage locker, four small containers were rusted on the inside. Staff stated these containers had been used to store sugar packets in the dining rooms, but were no longer used. The containers were discarded.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent.
Item No.: 27
Site: Preparation Room-Orange Juice Machine
Violation: Debris was built up inside the yellow plastic area around the metal chute.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 24
Site: Preparation Room-Sanitizing Solution
Violation: A bucket of sanitizing solution measured less than 50 ppm chlorine and was soiled with food debris. The solution was immediately remade.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 22
Site: Galley-Dishwash
Violation: On the dishwash machine, the electrical control panel showed a red alarm display. Crew members in the area continued to send dishes through the machine. The control panel stated there was an error with the final rinse water flow and the wash temperature. A visual inspection of the final rinse nozzles did not indicate an unusual flow pressure and manual temperatures of the wash and final rinse compartments were appropriate.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 20
Site: Buffet-Beverage Station
Violation: Both of the bulk milk dispensing tubes were longer than 25 millimeters (1 inch).
Recommendation: Cut bulk milk dispensing tubes 45 degrees on the diagonal, leaving no more than 25 mm (1 inch) protruding from the chilled dispensing head.
Item No.: 19
Site: Buffet-Crew Mess
Violation: Plates out for crew self-service were not inverted or covered.
Recommendation: During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
Item No.: 03
Site: Potable Water-Amazon River Water Production
Violation: The ship produced water all day while sailing through the Amazon River on 4 March 2014.
Recommendation: Operate a reverse osmosis unit, distillation plant, or other process that supplies water to the vessel?s potable water system only while the vessel is making way, and do not operate in polluted areas, harbors, or at anchor.
*Inspections scores of 85 or lower are NOT satisfactory