Cruise Ship: Asuka II Cruise Line: NYK Cruises Co., LTD Inspection Date: 05/30/2014 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 38
Site: Buffet-Lido Cafe
Violation: A jacket and several hangers were hanging from the rack with clean glasses. The bottom of the jacket was in contact with a rack of inverted clean glasses. The jacket and hangers were removed immediately.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 27
Site: Buffet-Lido Cafe
Violation: A significant amount of water was covering the bottoms of both bain marie technical compartments. It was determined that the water was from draining the bain maries too quickly.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 36
Site: Pantry-Lido Cafe
Violation: The light intensity to the left of the ice machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 21
Site: Buffet-Lido Cafe
Violation: The top of the technical compartment below the coffee machines was made of a pressed wood/paper material. It was torn in one area and there was water damage in a few areas.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 28
Site: Buffet-Lido Cafe
Violation: A jacket and several hangers were hanging from the rack with clean glasses. The bottom of the jacket was in contact with a rack of inverted clean glasses. The jacket and hangers were removed immediately.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination;
Item No.: 31
Site: Buffet-Lido Cafe - F&B Store Room
Violation: This room was an office and storage area. There were several containers of chemicals stored on the deck, including bleach, cleaner, metal polish, and lime remover. Food items such as two boxes of coffee creamers, a container of white pepper, and a few boxes of small snacks were stored in this room. The container of white pepper and a box of small snacks were on the deck adjacent to and touching a container of bleach. Food equipment such as a water boiler, straws, and coffee stirrers were stored in this room and at least three tea pots were stored on the deck.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 19
Site: Buffet-Lido Cafe - F&B Store Room
Violation: This room was an office and storage area. There were several containers of chemicals stored on the deck, including bleach, cleaner, metal polish, and lime remover. Food items such as two boxes of coffee creamers, a container of white pepper, and a few boxes of small snacks were stored in this room. The container of white pepper and a box of small snacks were on the deck adjacent to and touching a container of bleach. Food equipment such as a water boiler, straws, and coffee stirrers were stored in this room and at least three tea pots were stored on the deck.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 28
Site: Buffet-Lido Cafe - F&B Store Room
Violation: This room was an office and storage area. There were several containers of chemicals stored on the deck, including bleach, cleaner, metal polish, and lime remover. Food items such as two boxes of coffee creamers, a container of white pepper, and a few boxes of small snacks were stored in this room. The container of white pepper and a box of small snacks were on the deck adjacent to and touching a container of bleach. Food equipment such as a water boiler, straws, and coffee stirrers were stored in this room and at least three tea pots were stored on the deck.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 28
Site: Dining Room-Prego Restaurant
Violation: A small spray bottle of clear liquid was stored in a drawer in the display cabinet with individually wrapped toothpicks. It was determined that the spray bottle contained water.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 31
Site: Dining Room-Prego Restaurant
Violation: A spray bottle of alcohol was stored at the waiter station in an open cabinet with a small tray.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 19
Site: Buffet-Lido Cafe Omelet Station
Violation: The container of omelet toppings was less than one meter from where consumers would stand and it was not under a sneeze shield or otherwise protected. The container was moved immediately under a sneeze shield.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 16
Site: Buffet-Lido Cafe Omelet Station
Violation: There was a posted menu of items that could be ordered at the omelet station, including fried eggs, and a separate sign with consumer advisory, but there were no asterisks at the fried eggs or advisory statement to link the two.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 36
Site: Bar-Lido
Violation: The light intensity at the handwashing station was less than 110 lux during operations.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 37
Site: Galley-Dishwash Area
Violation: Condensate was dripping from the outside corner of the exhaust hood at the soiled end of the dishwash machine.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 24
Site: Galley-Dishwash Area
Violation: There was no water spraying from the final sanitizing rinse nozzles in the dishwash machine, and, therefore, the minimum utensil surface temperature of 160°F could not be reached.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 22
Site: Galley-Dishwash Area
Violation: There was no water spraying from the final sanitizing rinse nozzles in the dishwash machine. The temperature gauge for the final sanitizing rinse was indicating a temperature of 220°F. The pressure gauge was indicating a pressure of less than 5 psi. It was not clear if there was a problem with the gauges or if the temperature was too high and the pressure too low.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 20
Site: Pantry-Lido Grill
Violation: Three slotted fasteners were inside the microwave. There were also other difficult to clean features such as holes on the back and sides.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas. Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 36
Site: Galley-Starboard Dishwash Area
Violation: The light intensity behind the flight-type conveyor dishwash machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 17
Site: Galley-Cooling Logs
Violation: The actual cooling temperatures were not recorded on the logs. There were two columns on the log: one indicated 135°F to 70°F and the other indicated 70°F to 41°F. Times were recorded under each of these columns, but there was no place to record the actual measured temperatures.
Recommendation: Ensure the logs contain the actual cooling temperatures at start, after two hours, and after an additional four hours.
Item No.: 31
Site: Galley-Pastry
Violation: A spray bottle of alcohol was stored on a portable trolley.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 37
Site: Galley-Hot Section
Violation: Condensate was collected on the deckhead inside the exhaust hood above the cooking, uncovered steam kettle of seaweed broth. No condensate was observed dripping into the broth, but there was no one working in the area because of the boat drill. The kettle was immediately covered.
Recommendation: Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 20
Site: Galley-Hot Section
Violation: Slotted fasteners were around all of the light boxes inside the four combination ovens.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 37
Site: Galley-Hot Section
Violation: A significant amount of condensate was collected on the deckhead and exhaust hood above combination ovens 1 and 2. The condensate was dripping to the deck.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 20
Site: Galley-Hot Section
Violation: Slotted fasteners were in food contact surfaces of the deep fat fryers.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 36
Site: Galley-Cold Pantry
Violation: The light intensity around and behind the blast chiller was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Port Dishwash Area
Violation: The light intensity behind the flight-type conveyor dishwash machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 19
Site: Provisions-Beverage Walk-In 402
Violation: A bin with several small arrangements of pressed flowers was stored in this walk-in.
Recommendation: Do not store flowers in food storage areas.
Item No.: 37
Site: Provisions-Vegetable Room 2 407-2
Violation: Condensate was dripping from the deckhead. Bags of rice were stored below this drip, but a plastic sheet had been placed on top to protect the food.
Recommendation: Ensure condensate does not drip from the deckhead.
Item No.: 19
Site: Provisions-Vegetable Room 2 407-2
Violation: Condensate was dripping from the deckhead. Bags of rice were stored below this drip, but a plastic sheet had been placed on top to protect the food.
Recommendation: Protect food from contamination by storing the food: (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
Item No.: 33
Site: Galley-Hot Section
Violation: The deck grout was missing and recessed in several locations.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 36
Site: Galley-Potwash Area
Violation: The light intensity around and behind the potwash machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Bar-Bistro
Violation: The light intensity at the handwashing station was less than 110 lux during operations.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 20
Site: Bar-Bistro
Violation: Slotted fasteners were located on the coffee dispensing ports in the food splash area.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Bar-Bistro
Violation: No time control plan was posted for the self-service buffet.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used.
Item No.: 36
Site: Bar-Piano
Violation: The light intensity at the handwashing station was less than 110 lux during operations.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
Item No.: 10
Site: Recreational Water Facilities-Test Kit
Violation: The test kit used for the recreational water facilities (RWFs - swimming pool and whirlpool) only measured chlorine and pH and there was no way to measure alkalinity. There were also no secondary standards to check the calibration of the test kit. This was written on the previous inspection.
Recommendation: Ensure the test kit measures alkalinity. Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 10
Site: Recreational Water Facilities-Flow Meters and Monitoring
Violation: No flow meters were installed on the swimming pool or whirlpool. Combined chlorine was not being monitored.
Recommendation: Install flow meters. Monitor and adjust the RWF's flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
Item No.: 10
Site: Recreational Water Facilities-Disinfection of Filter Housings
Violation: There were no records of disinfection of the cartridge filter housing or sand filter housings after the filters or sand were replaced. This was written on the previous inspection.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Automatic Chlorine and pH Monitoring
Violation: There were no monitoring analyzers or chart recorders for monitoring the free chlorine and pH from the RWFs before the compensation tank or directly from the RWFs. There were strip chart recorders and analyzers installed, but the sample point for these was after the compensation tank. This was written on the previous inspection.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Turnover Rates and Bather Loads
Violation: Turnover rates were not calculated for the swimming pool or whirlpool. The bather loads were calculated using the manufacturer's theoretical pump rates instead of the actual flow rates.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool. Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow.
Item No.: 10
Site: Recreational Water Facilities-Fecal and Vomit Accident Plan
Violation: The fecal and vomit accident plan indicated a disinfection for loose stools at 100 ppm for 96 minutes instead of 100 ppm for 153 minutes.
Recommendation: Update the plan to include the value of 100 ppm for 153 minutes.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool Sand Filters
Violation: According to the staff, the sand was inspected every six months instead of quarterly, and there was no record of the inspection.
Recommendation: Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. For whirlpool spas and spa pools, ensure inspections and sedimentation tests are done monthly. For all other RWFs, ensure inspections and sedimentation tests are conducted quarterly. Change granular filter media for whirlpool spas and spa pools based on the inspection and sedimentation test results or every 12 months, whichever is more frequent. For all other RWFs, change granular filter media based on the inspection and sedimentation results or per the manufacturer's recommendations, whichever is more frequent. Record the results of both the filter inspection and sedimentation test.
Item No.: 44
Site: Recreational Water Facilities-
Violation: There were multiple violations related to the operation of the swimming pool and whirlpool, indicating that the vessel was not familiar with VSP's requirements for recreational water facilities.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Safety Sign
Violation: There was no safety sign posted at the entrance to the whirlpool. There was only a sign indicating the bather load.
Recommendation: Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. For children's RWF signs, include the exact wording "TAKE CHILDREN ON FREQUENT BATHROOM BREAKS" or "TAKE CHILDREN ON FREQUENT TOILET BREAKS." In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 02
Site: Medical-Acute Gastroenteritis Surveillance Logs
Violation: The electronic and printed AGE surveillance log format did not match the order of the fields and field content as provided for in the 2011 VSP Operations Manual, Section 13.2. This was also cited on the last inspection of the ship on 06/25/2012.
Recommendation: Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 11
Site: Medical-Food Worker Isolation
Violation: A Cabin Stewardess experienced the first onset of AGE symptoms on 04/11/2014 at 1400. This person did not report to the illness to the medical center until 04/12/2014. Work records showed that this attendant worked between symptom onset and reporting to medical. A similar citation was made on last inspection for late reporting of 1 food worker and 2 non-food workers. This person was not marked in the AGE log as a food worker, although the duties include handling food utensils in the room and ice. This person was returned to duty on 04/13/2014 at 1600, less than 48 hours after their last symptom.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. Ensure food employees who have conditions or symptoms of diarrhea report these conditions or symptoms promptly to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles. Ensure the restriction is not removed until the supervisor or person in charge of the food operation obtains written approval from the vessel's physician or equivalent medical staff.
Item No.: 26
Site: Pantry-Ice Pantry - Deck 8
Violation: Pink and gray mold were found on the water manifold in the ice maker unit.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Pantry-Ice Pantry - Deck 10
Violation: Gray mold was found on the water manifold in the ice maker unit.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 24
Site: Pantry-Ice Pantry - Deck 10
Violation: The undercounter dishwasher was on when the inspection team entered the room. This dishwasher was run 6 times and never reached the appropriate sanitizing temperature of 160°F as shown on irreversible thermolabels. The final test included the ship's maximum registering thermometer which read 124°F at the end of the cycle.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 22
Site: Pantry-Ice Pantry - Deck 8
Violation: The dishwasher final rinse gauge read 196°F when the final rinse cycle was activated. This reading was inaccurate by at least 50°F over the actual final rinse sanitizing temperature.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (2) water temperature-measuring devices are maintained in good repair and accurate within the intended range of use. Ensure water temperature-measuring devices are scaled: (1) in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to within 1.5°C (within 3°F) in the intended range of use; (2) only in Fahrenheit are designed to be accurate to within 3°F in the intended range of use.
Item No.: 06
Site: Potable Water-Electronic Halogen Measurement Instrument Calibration
Violation: The secondary calibration standards were not available for the manual halogen test instrument calibration checks. An example for the ship's unit was sent by email during the inspection.
Recommendation: Where available, maintain appropriate secondary standards onboard for electronic halogen test kits to verify test kit operation.
Item No.: 08
Site: Potable Water-Potable Water Tank Maintenance
Violation: The certification document from an independent organization for the coating material used in the tank was not available at the time of the inspection.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer).
Item No.: 08
Site: Potable Water-Potable Water Bunker Hoses
Violation: Two new bunker hoses were not labelled 'POTABLE WATER ONLY' near the connecting ends.
Recommendation: Label potable water hoses with the words "POTABLE WATER ONLY" in letters at least 13 millimeters (0.5 inch) high at each connecting end.