Item No.:
02
|
|
Site:
Medical-Questionnaire
|
|
Violation:
The food/beverage questionnaire could not be located for a crew member, who experienced gastrointestinal illness on the July 20-27 voyage.
|
|
Recommendation:
Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
|
|
|
Item No.:
11
|
|
Site:
Medical-
|
|
Violation:
According to the medical logs, a food handler experiencing gastrointestinal illness (GI) was not isolated for 48 hours. The documentation stated the crew member experienced the last GI symptom on 22 July at 0900, and was cleared for duty on 23 July at 0600.
|
|
Recommendation:
When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Striping
|
|
Violation:
The water line was painted blue before the chlorine injection point, indicating this was a potable water line.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tanks
|
|
Violation:
Potable water tank #2 did not have a sample cock.
|
|
Recommendation:
Ensure potable water tanks have labeled sample cocks that are turned down. Identify the sample cocks with the appropriate tank number.
|
|
|
Item No.:
02
|
|
Site:
Medical-Close Contact Interview
|
|
Violation:
The 24-hour cabin mate interview of a symptomatic crew member was not conducted/documented on the July 20-27 voyage. Documentation was available for the initial and 48-hour interviews for the cabin mate.
|
|
Recommendation:
Maintain the following records on board for 12 months and make them available for review by VSP during inspections and outbreak investigations: (4) interviews with cabin mates and immediate contacts of crew members with AGE [initial, 24-, and 48-hour].
|
|
|
Item No.:
19
|
|
Site:
Buffet-Passenger and Crew Buffet
|
|
Violation:
In the hot buffet section, the handles for the serving utensils were in contact with the foods in the serving pans. This was noted for both of the scrambled egg dishes, the sausage patties, and most notably the crepes and jelly.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Passenger and Crew Buffet
|
|
Violation:
The chafing dish of hot oatmeal on the counter was not placed beneath a sneeze shield for passenger and crew self-service. The serving spoon was on a plate in front of the chafing dish, but was also not shielded. At the toaster oven, two plates containing an uncovered and unshielded small bowl of butter and peanut butter with serving knives were observed.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Passenger and Crew Buffet
|
|
Violation:
The large, covered wicker basket of sliced bread had a heavy dust soil present in the crevices between the woven basket sections.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris. It is recommended to replace the basket with a simple and smooth covered bin or other container, which is easier to clean.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The white plastic pitchers labeled creamer located on the soiled dishwash landing had very difficult-to-clean combination serving spouts. These spouts were made of several pieces, some of which contained voids and crevices, which were not accessible for cleaning. In addition, the steel coffee pitchers had attached lids, which did not allow them to be placed inverted on the dishware racks and required partial handwashing. The neck was too narrow for manual washing without special brushes to access the full interior of these pitchers.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (3) finished to have a smooth, easily cleanable surface. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The in-use stationary rack dishwash machine final rinse pressure gauge displayed 30 psi during the final rinse cycle. The manufacturer's dataplate specified a final rinse pressure of 15-25 psi.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley
|
|
Violation:
Two raw wood boards were set in forward positions on the deck to fix the rubber deck mats in place. The wood boards were not sanded smooth or varnished to be non-absorbent.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley
|
|
Violation:
The two Lang range oven grease pan housings were deep voids, where access to clean was restricted and made cleaning very difficult.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley
|
|
Violation:
A slot-head screw was observed fastened into the left splash panel at the flat-top grill. Slot-head screws were noted fastened to the right exterior oven for the three vent covers installed at the left side splash back for the dough counter aft. Finally, slot-head screws were fastened inside the two Lang ovens for shelf supports, interior steel panels, and the fan guard.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Dry Storage Room
|
|
Violation:
A long bundle of power cables attached to the back side of the storage rack were observed at the left side of the entry into the dry store room. The cables were in contact with the shelf and in some cases the packaged boxes stored on the shelf.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Bar-Lounge - Self-Service Beverage Station
|
|
Violation:
A layer of dust debris was observed on the top exterior surface of the ice and water dispenser, which was beyond one day's accumulation.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Bar-Lounge - Self-Service Beverage Station
|
|
Violation:
Carpeted deck covering was noted at the self-service beverage station, part of which was stained from a spill. Staff stated this area was to be covered with an easily cleanable deck tile in the upcoming renovation in October. This was also noted in the previous VSP inspection.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
|
|
|
Item No.:
36
|
|
Site:
Bar-Lounge - Self-Service Beverage Station
|
|
Violation:
The light intensity was below 110 lux between the ice and water dispenser and the bulkhead beside.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
21
|
|
Site:
Bar-Bar
|
|
Violation:
The two undercounter reach-in refrigerators were not sealed to the deck and were mounted on legs less than the minimum 150 mm above the deck.
|
|
Recommendation:
Ensure deck-mounted equipment that is not easily movable is sealed to the deck or elevated on legs that provide at least a 150 mm (6-inch) clearance between the deck and the equipment.
|
|
|
Item No.:
33
|
|
Site:
Bar-Bar
|
|
Violation:
A wine cork and other dirt debris were observed beneath the ice machine, and particularly near the back bulkhead, where it was difficult to reach.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
30
|
|
Site:
Bar-Bar
|
|
Violation:
The paper towel roll was empty at the handwash station in the bar.
|
|
Recommendation:
Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
|
|
|
Item No.:
33
|
|
Site:
Bar-Bar
|
|
Violation:
The deck and bulkhead juncture near the left undercounter reach-in refrigerator was not coved. Coving was absent at the bulkhead to deck juncture below the two undercounter reach-in refrigerators and the adjacent ice machine. This was most evident along the back bulkhead and deck.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
21
|
|
Site:
Bar-Lounge Locker
|
|
Violation:
Raw pressed wood board was exposed along the laminate shelf exteriors inside the locker and in all the small shelf support holes drilled along the side panels of the locker. This locker was used to store food.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Bar-Lounge Locker
|
|
Violation:
Gaps were present along the upper steel section of this locker and the exposed deckhead above where cables are present. In addition, gaps were present at the deck to the left side of the locker.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Bar-Lounge Locker
|
|
Violation:
Coving was absent at the juncture of the lower, base panel of the locker and each side panel. The base panel was not smooth and difficult to clean.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces. Exception: bars may have decorative surfaces provided that they are easily cleanable.
|
|
|
Item No.:
*
|
|
Site:
Other-Ship Supervisors
|
|
Violation:
Recommend supervisory staff such as hotel director, chef and master attend VSP training seminar or an equivalent program which focuses on the requirements of the VSP Operations Manual at the next available opportunity.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-Plan Review
|
|
Violation:
Staff stated that a renovation of at least the bar and lounge beverage counter was planned for October, 2014, and some drawings and a listing of jobs was reviewed on this inspection. Recommend a formal VSP plan review of this work, including some detailed description of specific equipment to be installed and cabinet work, sinks, etc. so the company can be made aware of all VSP Construction Guidelines which apply to this renovated area.
|
|
Recommendation:
|
|