Item No.:
01
|
|
Site:
Medical-Illness Reporting
|
|
Violation:
A required report of the acute gastrointestinal illness for this report had not been submitted for this international voyage which ended today or on previous international voyages since the last inspection. This report is required 24 hours before arrival, with a 4 hour update, if the number increases. It is also required at any time during a voyage if 2% of the passengers or crew members have acute gastrointestinal symptoms.
|
|
Recommendation:
Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours?but not more than 36 hours?before the vessel?s expected arrival at the U.S. port.
|
|
|
Item No.:
04
|
|
Site:
Potable Water-Far Point
|
|
Violation:
Three measurements of the far point halogen residual were taken. The results were 0.06, 0.04 and 0.06 PPM free chlorine. The ship's manual test at the same time also showed 0.1 PPM free halogen residual.
|
|
Recommendation:
Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
The far point analyzer reading was 1.5 -1.6 PPM free chlorine during the time that the inspection team was checking the far point halogen residual. The far point chart also had this same value for several hour prior to the inspection.
|
|
Recommendation:
Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer?s instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Reference Standards
|
|
Violation:
No secondary standards were available for the test kit used to monitor the free chlorine levels in the potable water system. This was noted on the two previous inspections.
|
|
Recommendation:
Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Halogen Charts
|
|
Violation:
Many of the halogen charts since last inspection were incomplete. The date was not recorded on more than 5 occasions, most lacked the year (2013), several had overlapping partial days recorded on the same chart, and some charts stopped part way through the day without any notation of the problem or manual readings for this period of time being recorded.
|
|
Recommendation:
Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer?s instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading. Record the daily manual comparison test or calibration either on the recorder chart or in a log. Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure the charts contain notations of any unusual events in the potable water system. In the event of equipment failure, measure the free residual halogen by a manual test kit at the halogen analyzer at least every 4 hours.
|
|
|
Item No.:
19
|
|
Site:
Galley-Food Storage Cabinet
|
|
Violation:
A plastic bin of sugar was not covered in the lower storage cabinet.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected.
|
|
|
Item No.:
19
|
|
Site:
Provisions-
|
|
Violation:
A carton of diet soda was stored directly on the deck.
|
|
Recommendation:
Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Galley-Hot Counter
|
|
Violation:
Cutting board had many deep scores in its surface making it difficult to clean. New cutting boards are on order and due to be delivered prior to next voyage.
|
|
Recommendation:
Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
21
|
|
Site:
Galley-Hot Counter
|
|
Violation:
There was a difficult to clean void present deep into the back and top sections of the flat grill grease pan housing. The housing itself was also difficult to access and clean as the depth of the housing was nearly two feet long because it was mounted too close to counter. Repairs were noted to improve the side gaps since the last inspection.
|
|
Recommendation:
Install table-mounted equipment that is not easily movable to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed to the table; or (2) Elevated on legs. Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
|
|
|
Item No.:
26
|
|
Site:
Bar-
|
|
Violation:
Mold was found at the top right and left sides of the cuber. Mold was also noted on the left side of the cuber supporting frame.
|
|
Recommendation:
Ensure food contact surfaces of equipment are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Bar-
|
|
Violation:
The top of the ice machine (in the open gap below the counter) was heavily soiled with dust.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Counter
|
|
Violation:
Old grease was noted in the crevices around the base of the flat grill housing at the seam with the counter.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Food Storage Cabinet
|
|
Violation:
Food spillage was noted in the bottom of the cabinet where the sugar bin was stored, particularly in the area around and below the sliding shelf at the bottom of the cabinet.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Provisions-
|
|
Violation:
Old chocolate chips were found spilled at the back of one of the storage shelves. The plastic crates used for stores had a buildup of old soil in the bottoms of crates.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of food residue, and other debris.
|
|
|
Item No.:
36
|
|
Site:
Bar-
|
|
Violation:
The light over the bar handwash sink was measured at 10 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|