Cruise Ship: Arcadia Cruise Line: P&O Cruises Inspection Date: 01/31/2015 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: A crew member reported to the medical center on 15 January at 17:55 after experiencing two episodes of diarrhea. The evaluation form used by the medical staff stated that these symptoms were above normal for the individual but he was listed on the AGE log as nonreportable. The crew member was still properly isolated and the immediate contacts were interviewed.
Recommendation: Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]).
Item No.: 11
Site: Medical-Crew Member Late Reporting
Violation: A crew member (nonfood worker) experienced five episodes of diarrhea on 15 January with symptom onset at 09:00 but did not report to medical until 16:40. Work records for this individual could not be retrieved to determine if this employee worked while symptomatic. Also, on 15 January a crew member (food worker) experienced two episodes of diarrhea with symptom onset at 10:30 but did not report to medical until 16:40. According to work records the employee worked from 09:00 to12:00. On 20 January a crew member (food worker) experienced eight episodes of diarrhea with symptom onset at 12:30 but did not report to medical until 19:30. According to work records the employee did not work while symptomatic.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 06
Site: Potable Water-Microbiologic Water Test Kit
Violation: The comparator used to analyze water samples for the presence of E.coli expired in March 2014.
Recommendation: Analyze samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Operate and maintain test kits, incubators, and associated equipment in accordance with the manufacturers' specifications.
Item No.: 10
Site: Recreational Water Facilities-Shock Halogenation
Violation: Several of the daily shock halogenation records for the hydropool and all the whirlpools were inaccurate when compared between the written records and the analyzer chart records since 1 January. For example, the manual records would indicate that the bromine levels were above 10 ppm at the start and end of the shock halogenation but some of the chart records showed either the bromine level to be less than 10 ppm during this time frame or show the bromine level above 10 ppm at the start of the shock halogenation and it dropped below 10 ppm before the one hour process was completed.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 09
Site: Recreational Water Facilities-Neptune Forward Whirlpool
Violation: The bromine level was above 10 ppm when measured by the inspector twice and 11.11 ppm when measured by staff. Additional tests were conducted from the sample line in the pool machinery room and the results were 9.20 ppm and above 10 ppm by the inspector and 11 ppm by staff. The whirlpool was open during the inspection and was immediately closed.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine.
Item No.: 19
Site: Pantry-Steward Station 8.4.05
Violation: A case and several loose bottles of water were stored on the deck.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 36
Site: Pantry-Lighting
Violation: The light intensity behind the ice machines in all the deck pantries was less than 110 lux. This was written on the previous two inspections.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 28
Site: Dining Room-Le Meridian
Violation: During breakfast service, all waiter stations had stacks of bowls and small plates that were not covered or inverted. Also, note pads were observed on top or in contact with small plates or silverware. All bowls, plates, and silverware were previously cleaned.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 21
Site: Galley-Potwash
Violation: The front-loaded potwash machine had several gaps between nonremovable panels, making these areas difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Deck 2 - Potwash
Violation: The in-use front-loaded potwash machine reached maximum temperatures of 153°F-154°F on several checks. The machine ran wash cycles without doing final rinse cycles. The machine was stopped for repairs.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Galley-Deck 2 - Potwash
Violation: The in-use front-loaded potwash machine reached maximum temperatures of 153°F-154°F on several checks. The machine ran wash cycles without doing final rinse cycles. The machine was stopped for repairs.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 27
Site: Galley-Deck 2 - Forward Food Preparation Area
Violation: When operated, water from the drinking fountain splashed onto the adjacent food preparation counter.
Recommendation: Do not allow water from the drinking fountain to reach the food preparation counter.
Item No.: 16
Site: Galley-Deck 2 - Hot Line
Violation: During breakfast service, several pans of hot potentially hazardous foods were on the food preparation counter with no discard labels. The posted time control plan stated that since the service was less than four hours, no discard labels were required.
Recommendation: As stated in the 2011 Operations Manual clarifications, label pans of potentially hazardous food on time control on preparation counters with 4-hour discard labels even if the outlet is open less than four hours.
Item No.: 26
Site: Galley-Ocean Grill Steakhouse Dishwash
Violation: On the clean racks, at least 5 cups were stored as clean but were soiled with food residues.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Ocean Grill Steakhouse Menu
Violation: Steaks could be cooked to order and a consumer advisory was on the menu. However, the steaks had no asterisk linking the advisory to the steaks. There was an asterisk after a statement under the Steaks heading stating that all steaks were aged for 28 days. Also, a buffalo burger could be cooked to order but an asterisk was after a truffle mayonnaise that could come with the burger.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 33
Site: Buffet-Officers Buffet Area in Ocean Grill
Violation: The deck behind, under, and in front of the buffet tables was carpeted.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 19
Site: Buffet-Officers Buffet Area in Ocean Grill
Violation: There was no side protection for the sneeze guards. The distance between where food was placed and where consumers were expected to stand was less than 1 meter.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 36
Site: Galley-Ocean Grill
Violation: The light intensity to the right and behind the ice machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Deck 2
Violation: The light intensity behind and around the ice machines and the pastry deck ovens was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 18
Site: Galley-Deck 2
Violation: Inside upright refrigerator SS2-5, a hotel pan of raw chicken breasts was stored over a tray with raw bacon. This was corrected.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another. (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas. (3) Cleaning and sanitizing equipment and utensils. (4) Storing the food in packages, covered containers, or wrappings. (5) Cleaning visible soil on hermetically sealed containers of food before opening. (6) Protecting food containers that are received packaged together in a case or overwrap from cuts when the case or overwrap is opened. (7) Separating damaged, spoiled, or recalled food being held on the vessel. (8) Separating unwashed fruits and vegetables from ready-to-eat food.
Item No.: 16
Site: Galley-Deck 2
Violation: Inside upright refrigerator SS2-6, a hotel pan of raw fish fillets had a temperature of 52°F-55°F. The fish was discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 20
Site: Galley-Deck 2
Violation: The ambient temperature of upright refrigerator SS2-6 was 52°F-55°F. Raw fish inside the refrigerator had the same temperature and was discarded after the finding.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 26
Site: Galley-Deck 2 - Cold Larder
Violation: The previously cleaned food slicer had a slight build-up of food residue and lint under the slicer's backplate next to the exit path of the food from the slicer blade.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Galley-Deck 2 - Room Service
Violation: In the cooking area of the microwave oven, excessive and pealing sealant was placed around the bottom panel. This excessive and pealing sealant was difficult to clean.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.
Item No.: 16
Site: Galley-Deck 2 - Room Service Menu
Violation: The multi deck burger could be cooked to order and a consumer advisory was on the menu. There was an asterisk next to the fries that could be served with the burger.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 26
Site: Galley-Deck 2 - Room Service Beverage Station
Violation: One of the juice dispensing ports of the previously cleaned left juice dispenser was soiled with juice residues.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 23
Site: Galley-Dishwash
Violation: The wash tank temperature of the in-use hood-type warewasher was 146°F in subsequent checks. The manufacturer's data plate specified a minimum rinse temperature of 150°F.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (2) 66°C (150°F) for a stationary-rack, dual-temperature machine.
Item No.: 22
Site: Galley-Potwash
Violation: The gauge for the hot water of the sanitizing compartment of the 3-compartment sink measured 180°F while the water temperature measured twice with different thermometers was 168°F.
Recommendation: Ensure water temperature-measuring devices are scaled: (1) in Celsius or dually scaled in Celsius and Fahrenheit are designed to be accurate to within 1.5°C (within 3°F) in the intended range of use; (2) only in Fahrenheit are designed to be accurate to within 3°F in the intended range of use.
Item No.: 24
Site: Galley-Potwash
Violation: The water of the in-use 3-compartment sink in the sanitation compartment was 168°F instead of a minimum of 171°F.
Recommendation: In a manual operation, if immersion in hot water is used for sanitizing, ensure: (1) the temperature of the water is maintained at 77°C (171°F) or above and (2) the food-contact surface is immersed for at least 30 seconds.
Item No.: 26
Site: Buffet-Crew Mess
Violation: The counter-mounted jacket potato machine was soiled on the food-contact and splash zones. Staff stated the machine was not in use.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Buffet-Crew Mess
Violation: The counter-mounted jacket potato machine had slotted fasteners in the food splash zones. Staff stated the machine was not in use.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Buffet-Crew Mess
Violation: The counter-mounted toaster next to the jacket potato machine had slotted fasteners in the food splash zone.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 31
Site: Buffet-Crew Mess Beverage Station
Violation: The previously cleaned and not in use juice dispenser had sticky dispensing spouts where they were inserted in the dispensing ports. Staff and a service technician stated that it could be a lubricant sometimes used in those locations. It was unclear if the lubricant was food-grade.
Recommendation: Ensure lubricants meet the requirements specified in 21 CFR 178.3570 Lubricants with Incidental Food-Contact, if they are used on food-contact surfaces, on bearings and gears located on or within food-contact surfaces, or on bearings and gears that are located so that lubricants may leak, drip, or be forced into food or onto food-contact surfaces.
Item No.: 36
Site: Buffet-Crew Mess Beverage Station
Violation: The light intensity behind and around the counter-mounted equipment was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 39
Site: Buffet-Crew Mess
Violation: One fly was flying behind the buffet line during lunch service.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 26
Site: Buffet-Crew Mess
Violation: Several bowls out for service were either soiled with food residues or dripping wet.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Buffet-Crew Mess
Violation: Several out for service bowls were either soiled with food residues or dripping wet.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 36
Site: Pantry-Crew Bar
Violation: A deckhead light fixture in front of the upright refrigerators was not working resulting in a light intensity of less than 220 lux in that area.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 19
Site: Pantry-Crew Bar
Violation: Twelve bottles of water were stored directly on the deck. This was corrected.
Recommendation: Protect food from contamination by storing the food: (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 16
Site: Buffet-Crew Mess
Violation: During the set-up for lunch service, the initial temperature of two large containers of cut lettuce being placed on time control on the buffet counter and the undercounter refrigerator was 51°F-55°F. The lettuce was discarded.
Recommendation: If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Item No.: 20
Site: Buffet-Crew Mess
Violation: The thermometer used by the person in charge of checking the initial temperatures of the foods before placement on time control was out of calibration. This was verified when the staff and the VSP inspector checked the calibration of their thermometers with an ice bath.
Recommendation: Ensure food temperature measuring devices: (1) scaled only in Celsius or dually scaled in Celsius and Fahrenheit are accurate to within1°C (within 2°F) in the intended range of use; (2) scaled only in Fahrenheit are accurate to within 2°F in the intended range of use. Ensure food temperature measuring devices have a numerical scale, printed record, or digital readout in increments no greater than 1°C (2°F) in the intended range of use.
Item No.: 22
Site: Other-Deck A - Cambusa Square
Violation: Two refrigerator trays were stored on the deck leaning on a bulkhead. Staff stated they should have been taken to a warewash area.
Recommendation: Ensure soiled equipment is taken immediately to a warewash area.
Item No.: 19
Site: Other-Deck A - Cambusa Square
Violation: Numerous beer kegs and bottle water cases were stored in this area. The deckhead was open to wiring and pipes that were heavily soiled.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Other-Deck A - Cambusa Square
Violation: Numerous beer kegs and bottle water cases were stored in this area. The deckhead was open to wiring and pipes that were heavily soiled.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 24
Site: Galley-Belvedere Dishwash
Violation: The final rinse temperature of the in-use flight-type dishwash machine was 146-153°F in several checks. The machine was stopped for repairs.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 20
Site: Galley-Neptune Grill
Violation: There were slotted fasteners around the light fixture of the cooking area inside the combination oven.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 19
Site: Galley-Neptune Salad Counter
Violation: There was no side protection for sneeze guards. The distance between where food was placed and where consumers were expected to stand was less than 1 meter.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 36
Site: Galley-East Restaurant
Violation: The light intensity at the hot section handwashing station was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 14
Site: Galley-Deck 3 - Potwash
Violation: A food employee working at the prewash station was not wearing a hair restraint. This was corrected.
Recommendation: Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
Item No.: 20
Site: Galley-Deck 3 - Food Preparation Arera
Violation: The water flow coming from the spout of the drinking fountain was very low, requiring the user to make mouth contact with the spout.
Recommendation: Ensure the water stream from the drinking fountain is sufficient enough to prevent mouth contact from the user.
Item No.: 33
Site: Galley-Deck 3 - Bread Locker
Violation: The deckhead-mounted speaker over stored bread was heavily soiled with black debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 20
Site: Galley-Deck 3 - Pastry
Violation: There were slotted and corroded fasteners in the cooking area of both Blodgett ovens.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 39
Site: Galley-Deck 3 - Pastry
Violation: There was one fly around the beverage station area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 36
Site: Galley-Lighting
Violation: The light levels behind galley cooking equipment were measured at less than the required 110 lux. Examples included: Deck 2 Main Galley, the light levels were 70-100 lux behind combination steamer ovens #JC/020706 and --707; Deck 3 Main Galley the light levels were 30-40 lux behind the three combination steamer ovens; and Deck 9 Belvedere Food Court galley behind all the combination steamer ovens the light levels were less than 110 lux. This was cited in the 30 September 2014 and 1 February 2014 inspections in same locations.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.