Item No.:
33
|
|
Site:
Galley-Pool Grill
|
|
Violation:
Several of the light fixtures above the pool grill and in the corridor leading to the pantry had an accumulation of dead insects. This was written on the last inspection report. During the inspection this was reported as corrected by the staff, but not verified.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
37
|
|
Site:
Galley-Pool Grill Pantry
|
|
Violation:
Condensation had accumulated on the deckhead air diffuser and was dripping on the deck. The area was not in operation at the time of the inspection.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
33
|
|
Site:
Other-Pool Storage Locker
|
|
Violation:
The door frame and the door of this galley utensil locker was made of wood. The wood was varnished, but scratched and scored making cleaning difficult.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
08
|
|
Site:
Pantry-Panorama
|
|
Violation:
The intermediate vent of the backflow preventer for the ice machine was clogged with a substantial amount of debris. During the inspection this was reported as corrected by the staff, but not verified.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
16
|
|
Site:
Buffet-La Terraza
|
|
Violation:
A milk container, adjacent to the espresso machine, was reported by staff to be on time control, but the time control plan of the area did not list this counter as being on time control. This was corrected.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Galley-La Terraza
|
|
Violation:
The time control plan for the area stated the 'mise en place' potentially hazardous foods (PHFs) on food preparation counters would be labeled with set-up and discard times. The 'mise en place' PHFs on the counter for the preparation of egg and omelets did not have labels.
|
|
Recommendation:
If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
|
|
|
Item No.:
17
|
|
Site:
Galley-La Terraza
|
|
Violation:
The cold food cooling logs for 16 March had several entries of sliced vegetables, potatoes, and herbs, which stated only initial food temperatures and no cooling food temperatures or comments written to verify food was cooled to 41°F within four hours. Staff reported the food was served immediately after it was sliced.
|
|
Recommendation:
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
22
|
|
Site:
Galley-La Terraza Scullery
|
|
Violation:
The undercounter warewasher was out of service. Staff reported it broke two days ago. Also, the data plate of the machine did not state the wash and final sanitizing rinse times, as specified by the manufacturer.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines. Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Scullery
|
|
Violation:
Dripping was observed from the in-use rack-type conveyor warewasher from under the wash tank to the deck. This was corrected.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
35
|
|
Site:
Galley-Scullery
|
|
Violation:
Water was pooled under the in-use rack-type conveyor warewasher; the machine was leaking used water from under the wash tank to the deck.
|
|
Recommendation:
Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
|
|
|
Item No.:
22
|
|
Site:
Galley-Potwash
|
|
Violation:
The potwash machine was out of service since 30 November 2014. This was written on the previous inspection report. Staff presented documentation to the inspector to verify the replacement of the machine during the next dry-dock scheduled for October 2015.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
38
|
|
Site:
Galley-Coffee Station Pantry
|
|
Violation:
A mop and two buckets were stored in the area. The mop was wet and not stored in a way that would not allow it to air-dry.
|
|
Recommendation:
After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
21
|
|
Site:
Galley-Dining Room Coffee Station
|
|
Violation:
The top of the toaster was corroded.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
20
|
|
Site:
Galley-Dining Room Coffee Station
|
|
Violation:
The food contact surfaces of the toaster were corroded.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Galley-Dining Room Coffee Station
|
|
Violation:
Two large slotted fasteners were placed in the side panels of the food contact surfaces of the bread slicer.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pastry
|
|
Violation:
The deck in front of the ice cream machine had recessed grout, and water was pooled under and between the tiles.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry
|
|
Violation:
Two live flies were circulating in front of the ice cream machine.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pastry
|
|
Violation:
A profile strip was missing on top of the upright refrigerators creating a gap on the bulkhead.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
20
|
|
Site:
Galley-Hot Section
|
|
Violation:
The food employee actively cooking burgers did not have a tip-sensitive thermometer; none of the staff in this area had a tip-sensitive thermometer. This was corrected.
|
|
Recommendation:
Ensure food temperature-measuring devices are provided and readily accessible for use in ensuring attainment and maintenance of food temperatures. Use tip-sensitive temperature-measuring devices, such as a thermocouple or thermistor, for measuring thin food products.
|
|
|
Item No.:
37
|
|
Site:
Galley-Scullery
|
|
Violation:
A large amount of condensation was collected on the deckhead air diffuser between the soiled storage racks. The condensation was dried after the finding.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent condensation from collecting on bulkheads and deckheads. Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
37
|
|
Site:
Preparation Room-
|
|
Violation:
A large amount of condensation was collected on the bulkhead next to the in-use band saw and the adjacent food preparation counter.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|