|
|
|
Item No.:
16
|
|
Site:
Other-Engine Control Room
|
|
Violation:
An open container of milk on temperature control was in the undercounter refrigerator at a temperature of 65°F. It could not be determined when the milk carton was opened. The milk was discarded.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
|
|
|
Item No.:
33
|
|
Site:
Other-Engine Control Room
|
|
Violation:
The deck under the undercounter refrigerator was heavily soiled with dust and debris.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Other-Engine Control Room
|
|
Violation:
The inside of the undercounter refrigerator unit was soiled with debris. Milk and yogurt were stored in the refrigerator.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
41
|
|
Site:
Other-Engine Control Toilet Room
|
|
Violation:
The toilet room did not have soap, a sign advising users to wash hands, and was not equipped with a bare hands-free exit.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (1) Hot and cold running water; (2) Soap; (3) A method to dry hands; (4) A sign advising users to wash hands. Equip passenger and crew public toilet facilities so persons exiting the toilet room are not required to touch the door handle with bare hands. Where toilet stalls include handwashing facilities, ensure the bare-hands-free contact begins in the toilet stall. Ensure that toilet facilities with multiple exits, such as spa dressing rooms, have bare-hands-free contact at each exit. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Records
|
|
Violation:
Since 19 February the forward bridge loop chart records were scaled from 0-10 ppm. Staff hand wrote a scale from 0-5 ppm on the chart records. Since 18 February the deck 9 aft loop chart records were scaled from 0-10 ppm. Staff hand wrote the 0-5 ppm scale on each chart record. Staff stated the regular 0-5 ppm chart records had been ordered and were to arrive in Europe.
|
|
Recommendation:
Ensure the halogen analyzer-chart recorder charts have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of (and limited to) 24 hours.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross-Connection Log
|
|
Violation:
The cross-connection log did not include the four backflow prevention devices that were installed in the trolley wash area of the garbage room. The log also only included one air gap entry for the distillate water filling but there were two air gaps found during the inspection.
On the log for guest and crew cabins, the only connection listed was for the shower hose. No other entries for the toilets or whirlpool tubs were found. According to staff the same backflow prevention device used for the shower hose was also installed on the toilets and whirlpool tubs.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bone Crusher
|
|
Violation:
The potable water connection to the submerged inlets at the opening of the bone crusher did not have a backflow prevention device installed.
|
|
Recommendation:
Provide backflow prevention devices on all fixtures using potable water and that have submerged inlets.
|
|
|
Item No.:
07
|
|
Site:
Potable Water-Potable to Technical Water Transfer
|
|
Violation:
According to staff the ship had two transfer lines from a potable water tank to a technical water tank with no backflow prevention device or air gap. Staff stated this was from the original construction of the ship.
|
|
Recommendation:
Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Hair and Lint Strainer and Strainer Housing
|
|
Violation:
The description of the weekly sanitizing of the hair and lint strainer did not specifically mention the hair and lint strainer housing was included.
|
|
Recommendation:
Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Shock Halogenation
|
|
Violation:
The daily shock halogenation records of every whirlpool spas did not list a starting concentration at or above 10 ppm.
|
|
Recommendation:
Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Shower Head Disinfection
|
|
Violation:
The disinfection of the shower heads in the medical center was not documented.
|
|
Recommendation:
Clean and disinfect shower heads every 6 months. Disinfect with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
|
|
|
Item No.:
44
|
|
Site:
Potable Water-
|
|
Violation:
It took several hours to determine the cross-connection control protection within the production and bunker systems on the ship. Staff told the inspector the distillate water line from the evaporators to the distillate water tank broke off from the production line heading to the mineralizer and was hard plumbed to the tank without a backflow prevention device or an air gap, even though the cross-connection control log had an entry for the distillate water air gap. At one point staff thought the high salinity discharge on the evaporator was the backflow prevention device for the distillate tank but that left the high salinity discharge unprotected. It took several hours to locate the air gaps for technical water filling and distillate water filling.
Staff also told the inspector that a water line that was striped blue/green/blue for potable water by the mineralizer that was marked 'to technical' was a production line that bypassed the mineralizers and went directly to a technical water tank. Staff said it was not protected by an air gap or by a backflow prevention device. It was later determined this water line was a technical water line from a separate and independent technical water bunker line. After several hours the air gap for the technical water filling from the production line was found.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP-during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Technical Water Bunker Line
|
|
Violation:
The technical water bunker line that went directly to the technical water tank was striped blue/green/blue indicating potable water.
|
|
Recommendation:
Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
On 29 January a passenger was listed as nonreportable on the AGE log after reporting to the medical center with one episode of diarrhea and no other symptoms. Anti-diarrhea medication was dispensed and no underlying illness was documented. According to staff the patient was not a reportable case because the patient did not have 3 or more episodes of diarrhea. The medical staff did not ask if these symptoms were above normal for the passenger.
|
|
Recommendation:
Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]).
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Pot Wash
|
|
Violation:
The in-use hot water sanitizing sink had a water temperature measured manually of 173°F, but the mounted gauge for this sink displayed a temperature of only 160°F.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
16
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The posted time control plan included a flow of food that was incomplete. According to staff, foods were either prepared and moved directly to the food service counter for waiter pick-up or placed in trolleys that were rolled into the time control walk-in refrigerator or on the storage shelves there and moved out to the food service counter as needed. The written plan only mentioned the movement of food from preparation to service counter. Additionally, staff stated that they do have some loose pans of foods or sauces which are placed on preparation counters under time control with labels affixed with discard times, but the plan did not mention these loose pans or counters as being time control.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The blast chiller in this area was posted out of order. The repair request attached to the unit noted that the blast chiller was in disrepair since 14 January, 2015.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Pastry
|
|
Violation:
The far right door on undercounter reach-in refrigerator #079 had a gap between the lower half of the door and the door frame which was large enough to pass folded papers from the outside to the inside of the refrigerator.
|
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Aft Service Line
|
|
Violation:
Inside the center neutral cabinet was a stack of 20 small white plastic food serving trays that were previously cleaned. All had sharp edges around the ends, where the trays were severely chipped and the surfaces were difficult to clean as a result. Staff stated these were no longer used on the ship, but it was not clear why they were stored with other clean items.
|
|
Recommendation:
Discard or repair the broken serving trays.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Garde' Manger
|
|
Violation:
The walk-in refrigerator door handle was broken, causing the unit to be out of order. It had been in disrepair since 27 February, 2015.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Garde' Manger
|
|
Violation:
The door on undercounter reach-in refrigerator #093 had a gap between the lower half of the door and the door frame which was large enough to pass folded papers from the outside to the inside of the refrigerator.
|
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Sauce Station Port
|
|
Violation:
The right door on undercounter reach-in refrigerator #065 had a gap between the lower half of the door and the door frame which was large enough to pass folded papers from the outside to the inside of the refrigerator.
|
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
39
|
|
Site:
Preparation Room-Provisions - Bakery
|
|
Violation:
One live filth fly was observed on the back side of the middle of three large floor mixers during active preparation in the bakery.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
08
|
|
Site:
Buffet-Crew Mess - Beverage Station
|
|
Violation:
The insulated pipes on the back side of the two soft serve ice cream dispensing machines were not identified as chilled water pipes.
|
|
Recommendation:
Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Staff Mess
|
|
Violation:
The power cable for the juice dispensing machine was coiled on the counter below, making access for cleaning difficult.
|
|
Recommendation:
Shorten or hang the power cable to allow easy access for cleaning the counter.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Perla Buffet - Main Line
|
|
Violation:
Fourteen live fruit flies were observed on the deckhead throughout the main buffet line, most of which were on deckhead panel seams. One live fruit fly was observed on the handle of a serving tong inside an empty container on the buffet line counter. The buffet was not in service at the time of the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Perla Galley - Cold Counter Starboard
|
|
Violation:
Two live fruit flies were observed on the wicker baskets which were stored on the clean shelves at the cold counter.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
27
|
|
Site:
Galley-Perla Galley - Cold Counter Starboard
|
|
Violation:
There were over 40 individual wicker style woven baskets stored on the clean storage shelves at the cold counter. Staff stated that they were washed in the warewashing machine, but most had layered baking soil on exterior surfaces and many had actual pastry jam stuck between the woven layers. All were removed to be rewashed.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
39
|
|
Site:
Galley-Perla Galley Pot Wash
|
|
Violation:
A dead fruit fly was observed floating in an otherwise clear bucket of chlorine sanitizing solution.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Perla Galley - Pot Wash
|
|
Violation:
One live fruit fly was observed on the deckhead above the soiled pot/pan storage counter. Additionally, there were four live fruit flies observed on the deckhead and bulkhead over the clean pot storage rack in the aft/port corner of the pot wash.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
26
|
|
Site:
Galley-Perla Galley - Pot Wash
|
|
Violation:
A large portable bulk milk dispensing container was observed on the clean pot storage rack. When the dispensing head was removed there were old milk solids visible along the dispensing gasket which had a foul odor.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Galley-Perla Galley Dishwash
|
|
Violation:
There was a water leak from the deckhead very close to the water fountain below. The water was dripping onto the deck below.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|