|
|
|
Item No.:
11
|
|
Site:
Medical-Food Workers Not Reporting AGE
|
|
Violation:
In the medical records, it was noted that a waiter had an acute gastroenteritis (AGE) illness symptoms onset on 03/02/2015 at 19:00. The waiter did not report these symptoms to the medical center until 03/03/2015 at 1645. It was documented that the waiter worked during the day prior to the reporting of the diarrhea episodes.
This is the third successive USPH inspection where this serious non-reporting of AGE symptoms by food workers has been noted. The medical staff in this instance did isolate the crew members for the appropriate time after the resolution of symptoms.
A cabin attendant, who works with food utensils, also had AGE onset symptoms on 03/02 and did not report for almost 24 hours. The attendant also worked while ill with AGE symptoms.
|
|
Recommendation:
Ensure food employees who have conditions or symptoms of diarrhea or vomiting report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point Halogen Monitoring Charts
|
|
Violation:
Three far point charts had breaks in the data or where not changed in the 24 hour period without notation of the unusual occurrences that resulted in the loss of accurate recording of the free halogen residual.
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunker Chlorination
|
|
Violation:
On each of the more than 5 occasions where the ship has bunkered water in the past two months, the records showed that the bunkering chlorination never achieved at least 2.0 PPM free residual.
|
|
Recommendation:
Adjust the free halogen residual level to at least 2.0 mg/L (ppm) within 30 minutes of the start of the bunkering and production processes.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Inspection Records
|
|
Violation:
No records were available to show inspection of the non-testable backflow prevention devices, though staff members reported routinely doing the inspections. The blank inspection form with the listing of devices was in the water system records.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections. Inspect backflow prevention devices periodically and replace any failed units. Retain the inspection and test results for backflow prevention devices for at least 12 months and ensure they are available for review during inspections.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Deck 5 - Air Conditioning Room
|
|
Violation:
A buildup of green algae was found in AC Fan Unit #2 in the condensate pan. Another fan unit checked on another deck was completely clean.
|
|
Recommendation:
Keep air handling units clean.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Lido Garden
|
|
Violation:
At the center bread and coffee station, some of the plates out for passenger self-service were not inverted or covered.
|
|
Recommendation:
During service, ensure the food contact portion of each self-service food dispensing utensil is covered or located beneath shielding. Ensure that dishware, glassware, and utensils out for service are inverted or covered.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Lido Garden
|
|
Violation:
Breads and rolls were less than one meter from where consumers would stand and they were not fully protected by the sneeze shield.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
36
|
|
Site:
Buffet-Lido Cafe
|
|
Violation:
The light intensity was less than 220 lux in front of upright refrigerator LC-1. Also the light intensity was less than 220 lux at the adjacent handwash station.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Lido Garden / Lido CafeTime Control Plans
|
|
Violation:
The time control plans did not indicate the service period set-up and discard times. Staff explained to the inspector the times varied each day by about 30 minutes, but were always less than four hours service periods. Itemized lists of potentially hazardous foods on time control showed the set-up and discard times for the current breakfast service.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Update the time control plans to refer the reader to the "Four Hours Discard Itemized List" for the set-up and discard times. Ensure these lists are posted alongside the time control plans.
|
|
|
Item No.:
22
|
|
Site:
Galley-Prego Galley - Scullery
|
|
Violation:
Below the sanitizing compartment of the three-compartment sink, the hot water line valve was continuously leaking.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
36
|
|
Site:
Galley-Lido Cafe Pantry
|
|
Violation:
The light intensity was less than 220 lux at the handwash station.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
20
|
|
Site:
Galley-Lido Cafe Pantry
|
|
Violation:
Three slotted fasteners were on the sensor in front of the ice machine cuber panel.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
37
|
|
Site:
Galley-Scullery
|
|
Violation:
The area was very hot. Crew members working in the area were sweating. It appeared the ventilation power was not sufficient.
|
|
Recommendation:
Ensure all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
|
|
|
Item No.:
37
|
|
Site:
Galley-Lido Garden / Lido Cafe - Scullery
|
|
Violation:
Excessive condensation was on the deckhead and bulkhead at the clean end of the dishwash machine. Condensation was observed dripping from the hood overhang onto the deck. No clean items were impacted.
|
|
Recommendation:
Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Recommend to move the deckhead vent closer to the machine to collect condensation coming from the machine. Also, the hood overhang is approximately three centimeters in front of the machine. Recommend to extend the overhang to 150 mm in front of the machine to collect steam and heat coming from the machine when the doors are opened.
|
|
|
Item No.:
33
|
|
Site:
Galley-Lido Garden / Lido Cafe - Scullery
|
|
Violation:
The detergent supply lines were lying on the deck below the wash compartment of the dishwash machine.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Elevate the detergent supply lines above the deck to allow for easier cleaning.
|
|
|
Item No.:
22
|
|
Site:
Galley-Lido Garden / Lido Cafe - Scullery
|
|
Violation:
The manufacturer's data plate showed a speed of 96 or 150 baskets per hour.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
36
|
|
Site:
Galley-
|
|
Violation:
The light intensity was less than 220 lux at the handwash station near the Chef's office.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pastry
|
|
Violation:
Slotted fasteners were in the food splash area along the front inside of the deck oven.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
24
|
|
Site:
Galley-Potwash
|
|
Violation:
The water temperature was 21°C (70°F) inside the sanitizing compartment of the three-compartment sink.
|
|
Recommendation:
Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer?s label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
36
|
|
Site:
Galley-Hot Station
|
|
Violation:
The light intensity was less and 110 lux behind the combination ovens.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
19
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
A container of whole mangos still had their distributer's sticker attached. Staff stated these fruits were washed in the preparation room.
|
|
Recommendation:
Thoroughly rinse raw fruits and vegetables in water to remove soil and other contaminants before being cut, combined with other ingredients, cooked, served, or offered for human consumption in ready-to-eat form.
|
|
|
Item No.:
29
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
Between the upright refrigerators, the handwash station had a minimum temperature of 57°C (135°F). A work order had been placed earlier the day of the inspection stating cold water was not supplied.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
17
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
The cooling logs of cooked potentially hazardous foods contained columns labeled Time 1 (start cooling time), Time 2 (after four hours of Time 1: 57°C - 21°C), and Time 3 (after two hours of Time 2: 21°C - 5°C) with columns for each time to write the food temperatures. Times 2 and 3 did not correctly identify the correct method to cool potentially hazardous foods.
|
|
Recommendation:
Update the cooling logs. Time 2 shall be from 57°C (135°F) to 21°C (70°F) or less within 2 hours, and Time 3 from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
The cooling logs were not completed for three cooked potentially hazardous foods from the morning of the inspection. Only the starting temperatures were documented. Due to the incorrect times for when the temperatures were to be taken, the two-hour temperatures was not obtained.
Deep fried bean curd had a starting temperature of 96°C (205°F) at 08:00 and a temperature of 24°F (75°F) at 11:38. Cooked burdock had a starting temperature of 96°C (205°F) at 08:30, and a temperature of 14°C (57°F) at 11:38. Chicken had a starting temperature of 96°C (205°F) at 08:30 and at 11:40 was not in the blast chilled. Staff stated this food was being reheated for the lunch service.
|
|
Recommendation:
Ensure the cooling temperatures of cooked potentially hazardous foods are documented. Potentially hazardous foods shall be cooled from 57°C (135°F) to 21°C (70°F) or less within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within an additional 4 hours.
|
|
|
Item No.:
16
|
|
Site:
Galley-Cold Pantry
|
|
Violation:
Deep fried bean curd had a temperature of 24°F (75°F) three and a half hours after the start of cooling. The food should have been cooled to 21°C (70°F) within 2 hours.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
17
|
|
Site:
Galley-Cooling Logs
|
|
Violation:
The cooling logs of cooked potentially hazardous foods contained columns labeled Time 1 (start cooling time), Time 2 (after four hours of Time 1: 57°C - 21°C), and Time 3 (after two hours of Time 2: 21°C - 5°C) with columns for each time to write the food temperatures. Times 2 and 3 did not correctly identify the correct method to cool potentially hazardous foods.
|
|
Recommendation:
Update the cooling logs. Time 2 shall be from 57°C (135°F) to 21°C (70°F) or less within 2 hours, and Time 3 from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
21
|
|
Site:
Galley-Scullery
|
|
Violation:
The right side of the dish cabinet was loose at the bulkhead juncture near the handwash station. It appeared the silicone had come loose, creating a gap.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Officer's Mess
|
|
Violation:
Food items were less than one meter from where consumers would stand and they were not fully protected by the sneeze shield.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
36
|
|
Site:
Bar-Bistro Bar
|
|
Violation:
The light intensity was less than 110 lux at the handwash station while the bar was in operation.
|
|
Recommendation:
In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
|
|