Cruise Ship: Azamara Journey Cruise Line: Azamara Cruises Inspection Date: 03/30/2015 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-AGE Surveillance Logs
Violation: The AGE logs did not include the crew member's positions.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (8) crew member position or job on the vessel, if applicable.
Item No.: 08
Site: Potable Water-Medical Center Sits Bath
Violation: This bath tub had a shower hose attached to the faucet. The backflow prevention device on the shower hose was installed below the flood-level rim of the tub.
Recommendation: Move the backflow preventer to another position on the water supply line where it will not become immersed in water.
Item No.: 09
Site: Recreational Water Facilities-Port Whirlpool Spa
Violation: On 22 March, chart records indicated the port whirlpool spa had a bromine residual less than 4.0 ppm from 08:00 to 11:00. No notations were made on the chart or other log to indicate an alarm or corrective actions.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (6) whirlpool spas and spa pools, between 3.0 and 10.0 mg/L (ppm) free chlorine or between 4.0 and 10.0 mg/L (ppm) bromine.
Item No.: 11
Site: Medical-Crew Members Reporting
Violation: On 18 March, a Housekeeper experienced acute gastroenteritis (AGE) symptoms beginning at 10:20, and reported to the medical center at 11:04. His time card indicated he worked 08:00 - 10:50. No disciplinary action was taken. On 22 February, a Stateroom Attendant experienced AGE symptoms beginning at 01:10, but did not report to the medical center until 17:31. His time card indicated he worked 07:55 - 12:43. No disciplinary action was taken.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours.
Item No.: 13
Site: Galley-Windows Café Mini Galley
Violation: The crew member cooking eggs provided conflicting information when asked about temperatures related to his duties. He stated eggs were fully cooked to 145°F. When asked to what temperature the eggs should be cooked for hot holding on the buffet line, he stated 140°F and above. He repeated this temperature a few times when the question was asked different ways.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (6) Employees are properly cooking potentially hazardous food, being particularly careful in cooking foods known to cause severe foodborne illness and death, such as eggs and comminuted meats.
Item No.: 16
Site: Buffet-Windows Café ? Starboard Coffee Station
Violation: The time control plan was not updated to match the operations. The milk station was not included in the areas on time control, and the plan stated 'time control begins when potentially hazardous foods are removed from the hot or cold holding units and placed on the galley service lines.' The galley service lines were not a part of this venue.
Recommendation: Revise the time control plan to reflect all equipment in this facility where time control is used and that the equipment matches what is installed in the facility.
Item No.: 16
Site: Bar-Mosaic Café
Violation: The time control plan stated potentially hazardous foods in the display cabinet would be labeled with their 4-hour discard time. When the inspection team was in the area around 13:00, the food items were not labeled. The transportation logs indicated the foods were removed from temperature control at 11:58.
Recommendation: Follow written time control plan procedures.
Item No.: 17
Site: Galley-Cooling Logs
Violation: The cooling logs did not indicate that some potentially hazardous foods were cooled to 41°F (5°C) or below. On 27 March, taco meat began cooling at 21:35 with a temperature of 159°F. No further temperatures were documented. On 22 March, rice pilaf and cous cous began cooling at 20:30 with temperatures of 140°F and showed 47°F at 22:30. No further temperatures were documented for these food items. A chef stated these foods were new items on the cabin service menu and they were immediately discarded, but this was not indicated on the cooling log. On 20 March, vanilla sauce began cooling at 09:50 with a temperature of 170°F. A time of 11:05 was written on the log for the next temperature check, but no temperature was recorded.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Item No.: 19
Site: Galley-Pastry Walk-In Refrigerator
Violation: The distributer's sticker was still on some grapefruits. Staff stated these foods had been washed in the fruit/vegetable preparation area.
Recommendation: Remove the identification stickers from the outside surfaces of the grapefruits before washing.
Item No.: 19
Site: Buffet-Staff/Officer Mess
Violation: The sneeze guards did not fully protect many food items out for crew self service. Unprotected food items were less than one meter from where consumers were expected to stand.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 19
Site: Bar-Pool Bar
Violation: The counter ice bin lid was open. A crew member was working in the area, but he was not actively using the ice during the inspection.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item No.: 20
Site: Food Service General-Ice Machines
Violation: In the Windows Café mini galley and in the Pool Bar pantry, the ice deflector panels had the manufacturer's sticker on the front, preventing proper cleaning.
Recommendation: Remove stickers from interior ice machine components.
Item No.: 20
Site: Pantry-8 Aft Ice Machine
Violation: One slotted fastener was in the food contact area of the ice thickness sensor.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Pantry-7 Aft Ice Machine
Violation: One slotted fastener was in the food contact area of the ice thickness sensor.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 21
Site: Buffet-Windows Café
Violation: The door hinges for undercounter refrigerator #3 were loose, preventing the doors from completely closing.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 22
Site: Food Service General-Dishwash Machines
Violation: The in-use flight type dishwash machines in the Windows Café galley and in the main galley had their alarms flashing when the inspection team entered the areas. The machines' electrical control panels stated 'maintenance needed, battery empty.' The electrician stated this alarm did not affect the operation of the machines. Manual temperatures were obtained by the inspector and crew member and both machines were working properly.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 23
Site: Galley-Dishwash Area
Violation: During many cycles, the wash tank temperature gauge read 152-155°F. The manufacturer's data plate indicated a minimum temperature of 160°F (71°C). Staff stated the wash tank water had been replaced about two hours prior. Manual temperatures of the wash tank indicated appropriate temperatures.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine.
Item No.: 25
Site: Buffet-Windows Café
Violation: Near the entrance to the dishwash area, a wet sanitizing cloth was stored on a waiter tray.
Recommendation: Restrict wiping cloths to the following: (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 25
Site: Galley-Dishwash Area
Violation: A wet cloth was draped over the side of the container of sanitizing solution.
Recommendation: Restrict wiping cloths to the following: (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 26
Site: Buffet-Windows Café Smoothie Bar
Violation: One previously cleaned glass was soiled and stored in a rack in this area.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Dining Room-Aqua Lina
Violation: Inside the port side waiter station, one previously cleaned water carafe was stored wet. The carafe was returned to the dishwash area.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 28
Site: Galley-Near Cold Pantry
Violation: Inside the utensil locker, numerous previously cleaned pans and bowls were stored wet. Most of these items were stored stacked, with some tightly stacked together.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 30
Site: Galley-
Violation: Outside the main galley, the male food worker toilet room door was not self-closing.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 34
Site: Bar-Pool Bar
Violation: The utility sink faucet was continuously leaking.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 38
Site: Provisions-Beer/Wine Room
Violation: A ladder was stored near some boxes of beverages.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 38
Site: Galley-Near Cold Pantry
Violation: Inside the chemical locker, two wet mops were stored inside their mop bucket. Some dirty water was inside the buckets, which was the amount that came from the wet mops themselves.
Recommendation: After use, ensure mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 39
Site: Pantry-7 Aft Ice Machine
Violation: One live fruit fly was inside the cuber.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 44
Site: Medical-
Violation: The medical staff were not obtaining and/or documenting all the necessary information from crew members experiencing AGE symptoms. For example, only a reportable AGE case crew member's cabin mate was considered an immediate contact, and staff were not considering additional persons (boyfriend, girlfriend, spouse, etc.) Staff stated that crew members were only in relationships with their cabin mate. Secondly, the AGE log did not include the crew member's position. If the crew member had already signed off the ship, their information was not available in the electronic medical database, and their crew position could not be determined. If the crew member's position was known, but this position may or may not be a food handler, medical staff were not asking all necessary questions to determine proper isolation for the food handler. Third, when a person experienced one or two episodes of diarrhea and had no underlying illness, medical staff were not correctly applying the reportable case definition, and identifying them as nonreportable AGE cases. It was not determined and/or documented if the diarrhea was or was not above normal for those individuals. Also, medical staff were not initiating corrective actions for crew members who reported late to the medical center after experiencing AGE symptoms. The senior management or supervisor were not notified of late reporting or working while symptomatic. Lastly, it appeared medical staff were relying heavily on the electronic medical database to provide information. It took the inspection team a significant amount of time to get the answers to their questions because the information could not be found in the database, nor was the information documented on a hard copy form.
Recommendation: Ensure the supervisor or person in charge of medical operations related to AGE on the vessel demonstrates to VSP-during inspections and on request-knowledge of medical operations related to AGE, is able to demonstrate this knowledge by compliance with Section 4 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 4 of the VSP 2011 Operations Manual as it relates to their assigned duties.