Cruise Ship: Seabourn Quest Cruise Line: Seabourn Cruise Line Inspection Date: 03/31/2015 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Provisions-Deck 2 Forward Hotel Storage
Violation: Numerous pieces of food equipment, such as plates, plastic plate covers, utensils, and coffee cream containers, were stored in this area that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead junctures were not coved. Several boxes of new equipment were stored in this room, but the equipment noted above was not in its original packaging and some appeared to have been previously used. The storage shelves were made of galvanized steel and had difficult to clean seams and gaps.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Potable Water-Evaporators
Violation: Staff stated that there were air gaps for the high saline discharges of the evaporators. However, these could not be found during the inspection and were not included on the list of cross-connections.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly). Update the cross-connection control program and ensure it is accurate and complete.
Item No.: 08
Site: Potable Water-Suites 745 & 747
Violation: The shower hoses in the bathrooms of these suites had shower hoses long enough that could reach the deck and had no backflow prevention devices.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities.
Item No.: 28
Site: Dining Room-Main Dining Room Waiter Stations
Violation: Wine glasses were stored upright and unprotected on the shelves on each side of the waiter stations.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 28
Site: Dining Room-Main Dining Room Storeroom 4.3.47
Violation: Some food equipment, such as large serving plates and coffee urns, were stored in this room that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead junctures were not coved. Several boxes of new equipment were stored in this room, but the equipment noted above was not in its original packaging and some appeared to have been previously used.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 33
Site: Dining Room-Main Dining Room Storeroom 4.3.47
Violation: Some food equipment, such as large serving plates and coffee urns, were stored in this room that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead junctures were not coved. Several boxes of new equipment were stored in this room, but the equipment noted above was not in its original packaging and some appeared to have been previously used.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 22
Site: Galley-Potwash
Violation: The wash solution in the wash compartment of the three-compartment sink was heavily soiled with food debris and grease residue. The water and soap suds were yellow in color.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 20
Site: Galley-Starboard Ice Machine
Violation: The ice thickness probe had three slotted fasteners.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones.
Item No.: 22
Site: Galley-Starboard Warewash
Violation: The in-use rack-type dishwash machine was opened up and the water temperature in the wash compartment was measured at 154°F. The inspector and crew then sent their maximum registering thermometer through the machine and measured the final rinse temperate at 172-174°F. However, when inspecting the final rinse spray pattern it was discovered that the final rinse spray nozzles were not continually operating while racks were passing through. The final rinse would spray for about 10-15 seconds and then turn off for about 10-15 seconds and then start again. The racks that were sent through during the inspection were empty, but the area was in operation when the inspector arrived in the area. The ship's engineers looked at the machine and made some adjustments, including turning the machine off and on again, and selected a different operating program. After these adjustments the final rinse nozzles were continually operating when the machine was in-use.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Starboard Warewash
Violation: The bottom final rinse spray nozzle on the left side manifold and the far right spray nozzle on the upper final rinse manifold were partially blocked producing an ineffective spray pattern.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 36
Site: Galley-Bakery/Pastry
Violation: Three different light covers in the deck mounted oven were cracked.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 26
Site: Galley-Port Cold Galley
Violation: The recessed ledge on the back plate of the previously cleaned deli slicer was soiled with old food residue.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Dry Store
Violation: The deck under the middle deck stands was soiled with dust, debris, and some dry food residue.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 20
Site: Preparation Room-Potato Peeler
Violation: The top removable cover of the potato peeler was cracked and chipped, especially around the interior opening. This made cleaning difficult.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 28
Site: Provisions-Deck 2 Forward Hotel Storage
Violation: Numerous pieces of food equipment, such as plates, plastic plate covers, utensils, and coffee cream containers, were stored in this area that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead junctures were not coved. Several boxes of new equipment were stored in this room, but the equipment noted above was not in its original packaging and some appeared to have been previously used. The storage shelves were made of galvanized steel and had difficult to clean seams and gaps.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 19
Site: Provisions-Deck 2 Forward Hotel Storage
Violation: A couple cases of canned fruit juice were stored in this area that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead juncture were not coved. The juice cans were stored on galvanized steel shelves that had difficult to clean seams and gaps.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 20
Site: Galley-Crew Mess
Violation: The milk dispensing tube on the milk machine was longer than 1 inch.
Recommendation: Cut bulk milk dispensing tubes 45 degrees on the diagonal, leaving no more than 25 mm (1 inch) protruding from the chilled dispensing head.
Item No.: 21
Site: Buffet-Crew Mess Beverage Island
Violation: The front plastic panel on the ice/water dispenser was chipped, pitted, and in poor repair.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 36
Site: Buffet-Crew Mess
Violation: The light intensity at the food worker handwash station behind the buffet counter was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Buffet-Officer Mess
Violation: The light intensity behind and around the toaster and the juice and ice/water machine was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 22
Site: Galley-Restaurant 2 Warewash
Violation: When the inspector entered the area, one rack of plates and another rack of bowls were going through the rack-type dishwash machine. After those racks exited the machine it was opened up and the water temperature of the wash compartment was measured at 166°F. The inspector and crew then went to measure the final rinse temperature by holding a metal pole with a maximum registering thermometer attached to the end at plate level. However, no water was coming from the final rinse spray nozzles. After a different operating setting was selected on the machine the final rinse was continually spraying. It could not be determined how long the machine was operated without a final rinse or if the operating setting reset once the machine was opened.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 16
Site: Galley-Show Galley
Violation: The hotel pan of waffle mix and pancake mix was stored in the undercounter refrigerator in the aft section of the show galley with an internal temperature of 46-50°F. Both mixes had 5-day discard labels and were on temperature control. Both were discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 19
Site: Buffet-Colonnade
Violation: The carving station on the buffet line did not have side sneeze shields. Passengers could stand within one meter of exposed food on the carving station.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 36
Site: Buffet-Lido Grill
Violation: The right light in the middle compartment of the deck-mounted oven was missing a shield and did not have a shatter resistant light bulb.
Recommendation: Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
Item No.: 21
Site: Buffet-Lido Grill
Violation: The granite countertop on the center preparation island was cracked and chipped around the edges of the entire island. A large crack was also noted on the right end of the countertop. The edge of the granite countertop on the worker side was also cracked and chipped in several locations. One large crack was also noted by both induction warmers on the front counter.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Galley-Lido Grill
Violation: Water was continuously leaking from the relief vent on the backflow prevention device for the hood cleaning system, indicating a possible failure.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 21
Site: Bar-Observation Bar
Violation: The edge around the worker side of the top bar counter was chipped and cracked in several locations.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Bar-Observation Bar
Violation: The two side countertops used for tea time had carpet on the deck in front. Staff stated that assorted pastries, sandwiches, and tea would be set-up on these counters for passenger self-service.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 16
Site: Pantry-Observation Bar
Violation: The milk compartment on the espresso machine was listed on the time control plan as a time control unit but was not labeled as such.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 21
Site: Pantry-Observation Bar
Violation: The water supply line to the hot water dispenser was made of a braided material that was difficult to clean.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Bar-Seabourn Square
Violation: The water supply line to espresso machine was made of a braided material that was difficult to clean. The braided cord was soiled with coffee residue.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Bar-Seabourn Square
Violation: The water supply line to espresso machine was made of a braided material that was difficult to clean. The braided cord was soiled with coffee residue.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Provisions-Deck 2 Forward Hotel Storage
Violation: Numerous pieces of food equipment, such as plates, plastic plate covers, utensils, and coffee cream containers, were stored in this area that was not properly designed for food equipment storage. The deckhead had exposed pipes and wires and the deck/bulkhead junctures were not coved. Several boxes of new equipment were stored in this room, but the equipment noted above was not in its original packaging and some appeared to have been previously used. The storage shelves were made of galvanized steel and had difficult to clean seams and gaps.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).