Item No.:
*
|
|
Site:
Food Service General-Lighting / New Galley Equipment
|
|
Violation:
The ship is to be commended for the upgrade of the overall lighting in the dry and refrigerated storerooms, waiter stations and galley areas to exceed the USPHS standards. Substantial improvements were noted with the replacement of the galley equipment and dishwashers since the last inspection.
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Reverse Osmosis Unit
|
|
Violation:
The potable line for the water hose adjacent to this unit had the proper backflow prevention but was not striped in accordance with ISO 14726 (blue/green/blue) or blue only to indicate potable water.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals.
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 5 - Main Galley
|
|
Violation:
Two trays of cold cuts and cheeses planned for the crew lunch were out of temperature in a temperature controlled reach-in cooler. The tray closest to the door was at 9°C (48°F) The back tray was at 12°C (54°F). Both temperatures were measured using the inspector's calibrated thermocouple using a thin-tip probe, The digital thermometer on the outside of the machine showed the temperature in the reach-in cooler #30 to be at 1.5°-3°C (34°-37°F). An analog thermometer on the inside of the reach-in cooler showed the ambient temperature to be a 12°C (54°F). The engineer explained that the unit was just coming off the defrost cycle. The cold galley cooling log showed that product had been properly cooled to less than 5°C (41°F) about 90 minutes prior to this finding. Both trays were placed back in the blast chiller to document their proper re-cooling.
|
|
Recommendation:
Maintain potentially hazardous foods at 5°C (41°F) or less.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Deck 3 - Dry Stores - Room #302
|
|
Violation:
A can of sauerkraut had fallen to the deck behind a pallet stand in the back right corner of the storeroom. This can was discarded by the crew because of a dent on the seam.
|
|
Recommendation:
Protect food from contamination by storing the food: (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
21
|
|
Site:
Provisions-Deck 3 - Dry Stores - Room 302 (and others)
|
|
Violation:
Galvanized shelving units were found in the dry storage rooms of the ship. The types of food and packaging of food were well chosen for these shelves to reduce the chance of corrosion. The shelves were clean and well maintained.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Design and construct nonfood-contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure nonfood-contact surfaces of food equipment comply with American National Standards Institute (ANSI), National Sanitation Foundation International (NSF International), or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck 3 - Dry Stores - Room #302
|
|
Violation:
Dried peas were found along the bulkhead / deck seam on the right side of the storeroom.
|
|
Recommendation:
Ensure decks in food storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 - Main Galley
|
|
Violation:
The dumbwaiter deck was heavily corroded on the front left and right sides making it difficult to clean. It was evident that the staff was working hard to keep it clean and fresh paint had been applied to the non-corroded floor panel.
|
|
Recommendation:
Ensure decks in food areas are constructed and maintained for easy cleaning. Ensure decks in food areas are corrosion resistant.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 - Main Galley
|
|
Violation:
A bulkhead hatch frame next to the potato peeler in the soup and sauce preparation station was in disrepair. A gap to the interior of the bulkhead had been created.
|
|
Recommendation:
Ensure bulkheads in food areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Deckhead Cabling - Food Storage and Preparation Areas
|
|
Violation:
Exposed deckhead cabling was noted in the provisions cold rooms, dry rooms and some of the galley areas. Even though this makes the maintenance of these surfaces difficult to clean, they were maintained clean.
|
|
Recommendation:
Install exposed utility service lines and pipes so they do not obstruct or prevent cleaning. Ensure deckheads in food preparation, food and equipment storage areas are constructed and maintained for easy cleaning.
|
|