Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 07/24/2015 Inspection Score: 88
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Bunker Logs
Violation: The July 3, 7, 10, 16, 17, and 21 shoreside bunkering logs were incomplete and chlorine and pH testing was not conducted hourly. The records indicated the initial shoreside chlorine values and no pH was recorded. Almost all free chlorine values were less than 1.0 ppm.
Recommendation: Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water.
Item No.: 27
Site: Galley-
Violation: The middle shelf in the top left cabinet above the stoves was soiled with a heavy layer of oil. Most of the cooking oils were stored on this shelf.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-
Violation: The corner bulkhead to the left of the right oven was soiled with a layer of oily debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-
Violation: The side tracks for the sliding shelf in the lower sugar cabinet had a significant accumulation of sugar.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-
Violation: The sides of the plate warmer (lowerator) to the left of the flat stove was heavily soiled to the touch. The bottom of the plate warmer had an accumulation of dust, dirt, and other debris. A stack of clean plates were stored in the plate warmer.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Galley-
Violation: The sides of the plate warmer (lowerator) to the left of the flat stove was heavily soiled to the touch. The bottom of the plate warmer had an accumulation of dust, dirt, and other debris. A stack of clean plates were stored in the plate warmer.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 25
Site: Galley-
Violation: Three wet wiping cloths were stored on various parts of the counter. Staff stated the chlorine solution that the wiping clothes were normally stored in had already been dumped and the wiping cloths were no longer in use.
Recommendation: Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
Item No.: 23
Site: Galley-Dishwash Machine
Violation: The water temperature of the wash cycle was measured at 130°F by the inspector and on the wash temperature gauge during multiple cycles. Staff did not know exactly when the dishwasher was used last in the morning of the inspection, but the machine was on and had dishes and pans inside that appeared to have already been cleaned prior to the inspection.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (2) 66°C (150°F) for a stationary-rack, dual-temperature machine.
Item No.: 24
Site: Galley-Dishwash Machine
Violation: The final sanitizing rinse temperature at the plate surface did not reach above 150°F on the first two cycles, but it reached in the high 150°Fs during the subsequent cycles. Staff did not know exactly when the dishwasher was used last in the morning of the inspection, but the machine was on and had dishes and pans inside that appeared to have already been cleaned prior to the inspection.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 28
Site: Bar-
Violation: Juice pitchers and decanters were stored upright in the top cabinet to the left of the stereo equipment. Three of the juice decanters had standing water at the bottom. The cabinet did not have a door and had an opening to the deckhead above with exposed wires for the stereo system.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted. Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 26
Site: Bar-
Violation: Two previously cleaned coffee thermoses were stored soiled in the top cabinet to the left of the stereo equipment.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Bar-Beer Taps
Violation: The lines for the beer taps were soiled with debris when checked with a drinking straw. According to staff, the lines were last flushed and cleaned on 30 April.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 36
Site: Dining Room-Waiter Station
Violation: The light intensity at the water station could not be raised to 220 lux during cleaning operations.
Recommendation: In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 33
Site: Dining Room-Waiter Station
Violation: The deck in front of the waiter station was carpeted. There was no coving at the deck/bulkhead juncture.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 33
Site: Bar-Coffee Station
Violation: The deck in front of the coffee station across from the side of the bar was carpeted. There was no coving at the deck/bulkhead juncture.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 16
Site: Galley-
Violation: A commercially produced container of ricotta cheese was opened and dated on 16 July. This container was discarded.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 22
Site: Galley-
Violation: The ship did not have a maximum registering temperature-measuring device to verify the temperatures in the dishwash machine.
Recommendation: Provide a maximum registering temperature-measuring device to verify the temperature in the warewash machines and the three-compartment sink.
Item No.: 01
Site: Medical-Reporting
Violation: The 24-hour gastrointestinal illness (GI) report for the May 17-24 voyage stated 10 out of 20 passengers were GI cases. An updated correct report was submitted indicating there were no passenger GI cases, and this GI report was submitted one day after the vessel arrived at a U.S. port from a foreign port.
Recommendation: Ensure the AGE report contains the following: (1) name of the vessel; (2) port of embarkation; (3) date of embarkation; (4) port of disembarkation; (5) date of disembarkation; (6) total numbers of reportable cases of AGE among passengers, including those who have disembarked because of illness-even if the number is 0 (zero reporting); (7) total numbers of reportable cases of AGE among crew members, including those who have disembarked because of illness-even if the number is 0 (zero reporting); and (8) total number of passengers and crew members on the cruise.
Item No.: 02
Site: Medical-Specimen/Shipping Containers
Violation: The clinical specimen collection containers for bacterial agents were expired, and there were no containers for viral agents. A shipping container was not available to submit clinical specimens.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each), as well as a shipping container that meets the latest shipping requirements of the International Air Transport Association (IATA) and U.S. Department of Transportation for Biological Substances, Category B designated shipments (or higher). Ensure the vessel maintains the appropriate labels and markings required for shipping Biological Substances, Category B shipments. Ensure the vessel maintains appropriate refrigerant materials to keep clinical specimens cool. (see Annex 13.4 of the VSP 2011 Operations Manual.)
Item No.: 08
Site: Potable Water-Cross Connection Control (CCC) Log
Violation: The CCC log did not list the backflow preventer devices manufacturer's make and model.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Potable Water-Cross Connection Control (CCC) Log
Violation: The backflow preventer listed for the crew washing machine on the CCC log stated 'air gap.' Staff stated this was the dishwasher discharge line, and it was unknown if a backflow preventer was on the potable water supply line.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (13) hospital and laundry equipment.
Item No.: 08
Site: Potable Water-Cross Connection Control (CCC) Log
Violation: The four backflow preventers, double check with intermediate vents (Watts 9D-M2), on the potable water hose deck connections were not listed on the log.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 03
Site: Potable Water-Production Logs
Violation: The water production logs for the reverse osmosis unit were incomplete and chlorine and pH testing was not conducted every four hours. The records only indicated the initial chlorine values and no pH was recorded. Almost all free chlorine values were less than 2.0 ppm. Staff stated they were taking chlorine values from the potable water tanks, and recording those values on the production logs.
Recommendation: Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
Item No.: 03
Site: Potable Water-Bunker Logs
Violation: The July 3, 7, 10, 16, 17, and 21 shoreside bunkering logs were incomplete and chlorine and pH testing was not conducted hourly. The records indicated the initial shoreside chlorine values and no pH was recorded. Almost all free chlorine values were less than 1.0 ppm.
Recommendation: Continuously halogenate potable water to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter and adjust the pH so it does not exceed 7.8. Ensure the amount of halogen injected during bunkering or production is controlled by a flow meter or a free halogen analyzer.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: The two potable water tanks were last inspected, cleaned, and disinfected in January 2013.
Recommendation: Inspect, clean, and disinfect potable water tanks during dry docks and wet docks, or every 2 years, whichever is less.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Safety Sign
Violation: The sign did not state cautions against use by the following: individuals who are immunocompromised; individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; pregnant women, elderly persons, and children; and not exceeding 15 minutes of exposure.
Recommendation: In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Filter
Violation: There was no replacement cartridge filter onboard. Also, the cartridge filter had not been replaced since May and the manufacturer's recommendations did not state the frequency of cartridge filter replacement, so it was unknown when the filter should be replaced.
Recommendation: Inspect cartridge or canister-type filters weekly for whirlpool spas and spa pools. For all other RWFs, inspect cartridge filters every 2 weeks, or in accordance with the manufacturer's recommendation, whichever is more frequent. Inspect the filters for cracks, breaks, damaged components, and excessive organic accumulation. Change cartridge or canister-type filters based on the inspection results, or as recommended by the manufacturer, whichever is more frequent. Ensure at least one replacement cartridge or canister-type filter is available.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Filter & Hair/Lint Strainer
Violation: Staff were cleaning and inspecting the filter weekly, and sanitizing the hair and lint strainer weekly, but the filter housing cleaning and disinfection was not recorded and the hair and lint strainer and housing cleaning and disinfection was not recorded.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 08
Site: Potable Water-Tank Sample Cocks
Violation: The potable water tank sample cocks were not labeled and identified.
Recommendation: Ensure potable water tanks have labeled sample cocks that are turned down. Identify the sample cocks with the appropriate tank number.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool
Violation: The whirlpool spa water was changed weekly, and not every 72 hours.
Recommendation: Change the whirlpool spa water, including compensation tank, filter housing, and associated piping, every 72 hours, provided that the system is operated continuously and that the correct water chemistry levels are maintained during that period, including daily shock halogenation. Change spa pool water as often as necessary to maintain proper water chemistry. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Logs
Violation: The electronic data logger was not working from June 28 to 30, and staff were manually monitoring the chlorine and pH levels every four hours instead of hourly.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children's pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool
Violation: The whirlpool did not have a flow meter, and it was unknown if the turnover rate was less than 30 minutes.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (5) whirlpool spa: 0.5 hours.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool
Violation: The chlorine and acid injection ports inside the tub were directly adjacent to the sample intake for the chlorine and pH analyzer, and did not provide a representative sample for the whirlpool.
Recommendation: Ensure the chlorine and acid injection points inside the tub are far enough away from the analyzer sample line to ensure an accurate and representative sample is taken.
Item No.: 08
Site: Potable Water-Cross Connection Control (CCC) Log
Violation: The backflow preventer for the galley dishwasher was not vented.
Recommendation: Ensure the backflow prevention device is vented.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool
Violation: The drain cover stated 'VGB-2008' and 'for multiple drain use only,' yet the whirlpool only had one drain. No other documentation was available for the drain cover to verify it was an antientrapment drain cover. The drain was not used to drain the whirlpool, and the shut-off valve was kept closed. This drain line drained to the deck.
Recommendation: Provide paperwork to show the drain cover meets the VGB Standards.
Item No.: 44
Site: Potable Water-
Violation: The potable water production and bunkering was not conducted in accordance with the VSP operations manual because crew was not monitoring or recording the chlorine and pH values at all during potable water production and bunkering, except for the initial chlorine values. Also, the cross connection control log was incomplete and had several inaccuracies.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 44
Site: Recreational Water Facilities-
Violation: Persons responsible for the whirlpools were not maintaining the facility, its documentation, and necessary equipment in accordance with the VSP operations manual. This includes: (1) not having a safety sign with all the required information; (2) not having a replacement cartridge filter onboard; (3) not documenting the weekly disinfection of the hair and lint strainer and strainer housing and the filter and filter housing; (4) Dumping the water in the whirlpool every 72 hours instead of weekly; (5) Recording the chlorine and pH values every four hours when the data logger malfunctioned instead of every hour; (6) not having flow meters installed and a calculated turnover rate; (7) having the chlorine and acid injection ports inside the whirlpool tub directly adjacent to the analyzer intake; and (8) not having paperwork to prove the drain covers were antientrapment certified.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program