|
|
|
Item No.:
19
|
|
Site:
Dining Room-Self-Service Buffet
|
|
Violation:
Food containers were placed for breakfast service on the buffet by the sides of the buffet in a manner which these food items were not protected. Specifically, the container of oatmeal and two pans of pancakes were not under the shield and adequately protected. The sides of the buffet were installed vertically and were receded from the buffet basin.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Back Counter
|
|
Violation:
The drawers where utensils were placed had raw wood exposed.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Back Counter- Aft Port Side
|
|
Violation:
A gap was observed to the left of the undercounter refrigerator, and this was constructed of raw wood.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Dining Room-Back Counter- Aft Port Side
|
|
Violation:
The top of the undercounter refrigerator was soiled with dust and debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Upright Refrigerator
|
|
Violation:
The fan covers in the refrigerator were soiled with dust.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Galley-Ovens
|
|
Violation:
The two Lang oven grease pan housings were long and narrow with deep voids making cleaning difficult. This was noted on the last inspection.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Galley-Ovens
|
|
Violation:
The two Lang oven green housings were soiled with a heavy layer of dust.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
The deck to the left of the upright refrigerator was peeling away from the juncture with the stainless steel, exposing a gap. This gap was soiled with food residue, and was noted on the last inspection.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Ice Machine
|
|
Violation:
The deck under the ice machine was excessively soiled with dust and debris.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
20
|
|
Site:
Bar-Ice Machine
|
|
Violation:
The ice thickness probe of the ice machine had a slotted fastener. Staff reported this ice machine was going to be replaced.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
33
|
|
Site:
Bar-
|
|
Violation:
A gap was noted along the bulkhead to the left of the undercounter wine refrigerator and under the electrical cabinet. Excessive dust was noted in this gap.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-
|
|
Violation:
Food residue was noted along the deck/cabinet junctures, especially in the corners. The soil that was observed was beyond a day's accumulation.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
21
|
|
Site:
Bar-
|
|
Violation:
Sealant was missing or had receded on some areas, where there were seams, on the front bar counter where the equipment met the bulkhead.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Bar-
|
|
Violation:
Three bulkhead penetrations with protruding pipes and wires were observed, leading to a void space.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Bunkering - Records
|
|
Violation:
The potable water bunkering halogenation records for the months of July (14 times) and August (5 times) were not accurately logged. In every one of the July and August records, the free halogen residual recorded was between 0.2 ppm and 0.3 ppm. Initially, this indicated that bunkering was at these low levels, but in reviewing the pre-bunker test from shore indicated incoming values of 0.4-0.5 ppm and the analyzer chart records which were from 0.5-1.5 ppm on days when bunkering took place and one day following. These values were compared to the same days in the month for the charts prior to July when another engineer conducted the bunker chlorination tests. All of these records showed values above 2 ppm and had similar far point values the day of and the day following potable water bunkering.
|
|
Recommendation:
Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-IPM Plan
|
|
Violation:
The IPM plan did not include an inventory of the pesticides currently on board the vessel. Staff did find both the pesticide list and the MSDS sheets, which match each pesticide.
|
|
Recommendation:
Ensure the vessel's IPM Plan includes a record of pesticides used to control pests and vectors. Ensure that the record includes all pesticides currently onboard the vessel and those used in the previous 12 months.
|
|
|
Item No.:
14
|
|
Site:
Galley-Beard Restraints
|
|
Violation:
The chef had a beard and was involved in food preparation and service. No beard restraints were available onboard.
|
|
Recommendation:
Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
|
|
|
Item No.:
27
|
|
Site:
Dining Room-Back Counter- Aft Port Side
|
|
Violation:
The gap, noted above, was soiled with debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|