Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Crystal Symphony Cruise Line: Crystal Cruises LTD Inspection Date: 09/13/2015 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 19
Site: Buffet-Lido Starboard Side Omlete Station
Violation: Cooking oil was in an unlabeled spray bottle. This was corrected.
Recommendation: Ensure containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
Item No.: 20
Site: Galley-Preggo
Violation: A seam was observed between the back plate and the slicer of the deli slicer. Some sealant was present, but was missing on part of the seam.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 26
Site: Galley-Preggo
Violation: Food debris was noted between the back plate and slicer of the deli slicer.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 08
Site: Galley-Preggo/Silk Road
Violation: Continuous dripping was observed from the vent of the backflow preventer on the ice machine, indicating possible malfunction of the device.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 17
Site: Galley-Preggo
Violation: Some slices of prosciutto were stored in an upright refrigerator and no cooling log entry for this item were available.
Recommendation: Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 16
Site: Other-Silk Road
Violation: No asterisks were observed by the spicy tuna and yellowtail scallion rolls to indicate a public health advisory applies to these undercooked items on the sushi menu.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 30
Site: Other-Silk Road
Violation: Napkins, instead of paper towels, were stored inside the paper towel dispenser at the handwash sink at the show preparation area. This was corrected.
Recommendation: Ensure each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
Item No.: 20
Site: Preparation Room-Potato Peelers
Violation: Gaps were noted along the front opening of the potato peelers where the rubber gasket had receded.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 26
Site: Preparation Room-Potato Peelers
Violation: Gaps noted above in the potato peelers soiled with food debris.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 39
Site: Preparation Room-
Violation: One live fruit fly was observed.
Recommendation: Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Warewash
Violation: One live fruit fly was observed.
Recommendation: Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Preparation Room-
Violation: The deck was soiled with food debris under the potato peelers.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Preparation Room-
Violation: Condensate was observed on the deckhead, as a result of the area being previously cleaned. This area was not in operation at the time of inspection.
Recommendation: Ensure deckheads in food preparation areas are cleaned as often as necessary.
Item No.: 16
Site: Provisions-Fruit Walk-in Refrigerator
Violation: A trolley with six trays of cut melons and watermelon had internal food temperatures between 45°F and 57°F. These were discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 5°C (41°F) or less.
Item No.: 17
Site: Provisions-Fruit Walk-in Refrigerator
Violation: The cooling logs for the cut melons and watermelon could not be located, and they were prepared the morning of the inspection.
Recommendation: Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 19
Site: Provisions-Corridor
Violation: A food employee was transporting a tray of raw roast beef and the tray was not covered or protected.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item No.: 26
Site: Preparation Room-
Violation: Seeds were noted on the cutting board. This area was previously cleaned and not in operation.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-
Violation: A hole was observed in the deckhead, exposing a technical space, adjacent to the combination ovens.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 20
Site: Galley-
Violation: A seam was observed between the back plate and the slicer of the deli slicer.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 24
Site: Galley-Warewash
Violation: The in-use glasswash machine final rinse temperature gauge stated 205°F during the evaluation of the glasswasher and exceeded the maximum final rinse temperature of 194°F. When a 200°F thermolabel was placed on the outside final rinse manifold, it was activated and turned black. Steam was observed coming from the final rinse spray arms, and water was not hitting the racks. The technician was able to lower the final rinse temperature.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F).
Item No.: 22
Site: Galley-Warewash
Violation: Steam was observed coming from the final rinse spray arms, and water was not hitting the racks. The technician was able to lower the final rinse temperature.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 26
Site: Buffet-Mess
Violation: Rice was noted on a previously cleaned fork out for self-service at the crew mess buffet line.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 16
Site: Buffet-Officer Mess
Violation: Smoked salmon was out for service on the officer self-service line and no consumer health advisory was present.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 37
Site: Buffet-Officer Mess
Violation: Condensation had accumulated on the ventilation filters above the hot self-service line. No dripping was observed.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 16
Site: Galley-Bistro
Violation: One individual container of yogurt in the walk-in refrigerator had an internal temperature of 47°F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 5°C (41°F) or less.
Item No.: 20
Site: Galley-Bistro
Violation: Three slotted fasteners were observed in the food contact surface area of the espresso machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 33
Site: Other-Deck 3 Forward Consumable Locker
Violation: The deck of the locker was soiled and the deck/bulkhead juncture was not coved. Food equipment was stored outside of its original packaging. This included: a box of wine glasses, 7 stainless steel mixing bowls, 10 sauce bowls, bowls, forks, butter knives, spoons, and knives.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: 28
Site: Other-Deck 3 Forward Consumable Locker
Violation: Food equipment was stored outside of its original packaging and the locker was not constructed to dry storage standards. This included: a box of wine glasses, 7 stainless steel mixing bowls, 10 sauce bowls, bowls, forks, butter knives, spoons, and knives.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 21
Site: Other-Deck 3 Forward Consumable Locker
Violation: Food equipment was stored on galvanized shelving units with not easily cleanable features, such as gaps and seams. Food equipment was stored outside of its original packaging. This included: a box of wine glasses, 7 stainless steel mixing bowls, 10 sauce bowls, bowls, forks, butter knives, spoons, and knives.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-Trident Grill
Violation: On the bottom of the grooved top grill a hole was noted in the stainless steel panel. This hole had old food debris, beyond a day's accumulation of soil.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-Trident Grill
Violation: On the bottom of the grooved top grill a hole was noted in the stainless steel panel. This hole had old food debris, beyond a day's accumulation of soil.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-Trident Grill
Violation: A corroded gap, leading to technical area, was observed around the grease chute directly above the grease pan housing of the grooved top grill.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Other-Trident Grill
Violation: A gap was noted around the grease chute leading to the grease pan housing of the flat top grill.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 39
Site: Other-Trident Grill/Ice Cream
Violation: Three live house flies were observed behind the counter of this outside food service area.
Recommendation: Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 16
Site: Other-Ice Cream Bar
Violation: A can of whipped cream was on stored on the back counter of this bar, and this area did not have a time control plan for this area. The can of whipped cream stated this item should be kept refrigerated.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 5°C (41°F) or less.
Item No.: 36
Site: Other-Ice Cream Bar
Violation: This area is open until 1800, and no artificial lighting was installed over the back bar ice cream cone making and topping area. A finding from the last inspection (5/9/2015) stated the light intensity was not able to be adjusted to a minimum of 220 lux for cleaning, and nothing has been done to amend this item.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Food Service General-Lighting
Violation: The light intensity was less than 110 lux behind and around counter-mounted and deck-mounted equipment, such as ice machines and ovens, in numerous food outlets. This included: housekeeping pantries, main galley, lido galley, preparation galleys, etc. Management showed the inspector a Phase I and II plan to address and evaluate the lighting deficiencies, but the projected completion date was unknown.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 16
Site: Dining Room-Breakfast Menu
Violation: No asterisks were observed by the smoked salmon to indicate a public health advisory applies to this food item.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 25
Site: Dining Room-
Violation: A wiping cloth was not stored in the sanitizing bucket. This was corrected.
Recommendation: Restrict wiping cloths to the following: (1) Cloths used for wiping food spills are used for no other purpose; (2) Cloths used for wiping food spills are dry and used for wiping food spills from tableware and single service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment; (3) Dry or wet cloths used with raw animal foods are kept separate from cloths used for other purposes. Wet cloths used with raw animal foods must be kept in a separate sanitizing solution; (4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths are free of food debris and visible soil.
Item No.: 24
Site: Galley-Warewash
Violation: The final rinse temperature of the dishwasher was over the maximum 194°F requirement. This was verified by placing a 200°F thermolabel on the outside final rinse manifold and the dishwasher final rinse gauge stated the temperature was over 200°F. Water was observed hitting the plates as they passed through the final rinse spray.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F).
Item No.: 20
Site: Galley-Pot Wash
Violation: One long-handled strainer was among the clean pots and pans and heavy damage was observed to the metal strainer and multiple broken welds from previous repairs. The split metal where the strainer center attached to the cutter ring was sharp and difficult to clean. A similar finding was noted on the last inspection.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 17
Site: Galley-Pastry
Violation: A September 13th cooling log entry for Bavarian cream indicated the initial temperature of 178°F at 0700, but no additional temperatures were documented. At 1321, and manual temperature was 36°F. This was discarded.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
Item No.: 37
Site: Galley-Hot Section
Violation: Condensation was observed on the deckhead between the combination ovens and soup kettles.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 37
Site: Galley-Hot Section
Violation: Condensation buildup was noted on the ventilation hoods over the smaller tilting pans.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 37
Site: Galley-Hot Section
Violation: Condensation build up was noted on the ventilation hoods over the large tilting pans, and some dripping was observed. No food was impacted.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: *
Site: Medical-
Violation: For the 30 August - 13 September voyage, the acute gastroenteritis surveillance log indicated 840 passengers, but the report submitted to VSP indicated 817 passengers. It was determined 840 passengers arrived in Amsterdam on 30 August at the end of that voyage, and 817 passengers remained consistent from 6 September to the end of the current voyage. The highest number of passengers during the voyage was 844.
Recommendation: The highest number of passengers during the voyage should be reported.
Item No.: 08
Site: Potable Water-Tank #1
Violation: Following disinfection procedures in July, the chlorine level was not documented prior to the tank being placed back into service.
Recommendation: Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service. Document the free halogen residual level.
Item No.: *
Site: Recreational Water Facilities-Spa Pool Chart Records
Violation: A review of the spa pool chart records since the last inspection indicated some were scaled 0-5 ppm, and staff indicated they were using the 0-14 pH scale to record the bromine residual levels, This was written on the previous inspection. New charts were ordered on 10 May and received on 8 June, at which time they were put into use.
Recommendation: Dual-scale halogen analyzer-chart recorder charts used in recreational water facilities must be able to measure the full range of halogen/pH of the facility type to which the chart is installed.
Item No.: 10
Site: Recreational Water Facilities-Spa Pool Bather Load
Violation: The calculated bather load for the spa pool was 12 persons, but the safety sign stated 14 persons. A new sign with the calculated number of persons was posted by the end of the inspection.
Recommendation: Ensure the bather load on the safety sign is equal to or less than the calculated bather load.
Item No.: 08
Site: Potable Water-Air Gaps
Violation: The list of air gaps did not include those for the engine space, such as potable water filling of technical water tanks and the mineralizer backwash drain lines.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Ventilation-
Violation: In the A/C stations, the potable water lines for the handwash sink were striped as hot and cold water only, and not striped as potable water.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 38
Site: Pantry-Housekeeping Pantries
Violation: In all housekeeping pantries, the counter-mounted ovens had not been used for a long time and were no longer necessary.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 19
Site: Pantry-Deck 10 Midship
Violation: Inside the upright refrigerator, some pears still had the sticker attached to them.
Recommendation: Thoroughly rinse raw fruits and vegetables in water to remove soil and other contaminants before being cut, combined with other ingredients, cooked, served, or offered for human consumption in ready-to-eat form.
Item No.: 40
Site: Integrated Pest Management-Incoming Shipments
Violation: The list of incoming supplies for the day of the inspection had already been completed with no pests found. Loading operations were still in progress during the inspection. The form was not signed by the supervisor. Staff stated this form should not have been filed and it was immediately discarded.
Recommendation: Document any pests found once loading is completed.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program