Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 10/06/2015 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 26
Site: Buffet-La Terraza
Violation: The scoop inside the ice machine was soiled in two parts with what seemed to be food residues.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-La Terraza
Violation: A large container of mozzarella cheese was on the pizza preparation counter on time control and had no discard label. This was corrected.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard. Containers of POTENTIALLY HAZARDOUS FOOD under time control and placed on preparation counters must be labeled with the discard time, even if the outlet is open less than 4 hours.
Item No.: 26
Site: Galley-Potwash
Violation: On the clean racks, at least two tongs and one pan were slightly soiled with food residues.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 17
Site: Galley-Blast Chiller
Violation: A large pan of risotto was cooling down in the blast chiller. At the time of the inspection, the risotto had an internal temperature of 128°F. The cooling process of this cooked food was not being documented on a log. The food was discarded.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 23
Site: Galley-Dishwash
Violation: The wash temperature of the in-use hood-type warewasher was 141-144°F. The data plate indicated a required minimum wash temperature of 150°F.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (2) 66°C (150°F) for a stationary-rack, dual-temperature machine.
Item No.: 22
Site: Galley-Dishwash
Violation: The wash temperature of the in-use hood-type warewasher was 141-144°F while the wash temperature gauge measured 140°F. The gauge seemed to be in disrepair.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Pool Grill Pantry
Violation: The wash temperature of the in-use hood-type ware washer was 168°F while the wash temperature gauge measured 150°F. The gauge seemed to be in disrepair.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 39
Site: Galley-Pool Grill Pantry
Violation: One house fly was in the area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Consumable and Liquor Lockers
Violation: The decks were soiled with debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Port Dishwash
Violation: The in-use rack-type and hood-type warewashers were leaking water from underneath and water was pooling on the deck.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 35
Site: Galley-Port Dishwash
Violation: Water was pooled under the in-use rack-type and hood-type warewashers. The machines were leaking water from underneath.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 22
Site: Galley-Potwash
Violation: Water was leaking from under the three-compartment sink.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 35
Site: Galley-Potwash
Violation: Water was pooled on the deck under and in front of the three-compartment sink. The compartments were leaking water from underneath.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 33
Site: Galley-Decks
Violation: There were broken and missing tiles and recessed and missing grout in many of the food areas. These deck conditions allowed for pooled water between tiles. This was observed mainly in the pastry and potwash sections.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Decks
Violation: There were broken and missing tiles and recessed and missing grout in many of the food areas. These deck conditions allowed for pooled water between tiles.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Provisions-Champagne/Wine Walk-in Cooler
Violation: The deck was soiled with debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 19
Site: Provisions-Champagne/Wine Walk-in Cooler
Violation: A bottle of nutritional drink was on the deck under pallets.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Provisions-White Wine Walk-in Cooler
Violation: The back panel of the air handling unit was soiled with dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Provisions-Dry Store
Violation: The deck was soiled with debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Provisions-Durable & Consumable Lockers
Violation: Chinaware, single-service and single-use utensils were stored in their original packaging. The deckhead pipes, cables, and light fixtures had accumulated dust.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 08
Site: Potable Water-Reverse Osmosis (RO) Unit
Violation: One inch plastic drain tubing was connected from the top of the RO filter unit below the rim of a catch drain without backflow prevention device or air gap. The hose was removed.
Recommendation: Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch). Provide backflow prevention devices on all fixtures using potable water and that have submerged inlets.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program