Item No.:
10
|
|
Site:
Recreational Water Facilities-Turn Over Rates
|
|
Violation:
The turnover rates for all the recreational water facilities were calculated from the manufacturer's pump rate and not from the flow rate on the flow meter once installed. Progress is being made on these calculations.
|
|
Recommendation:
For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool. Use flow rates from flow meters to calculate turnover rates. Do not use the manufacturer?s pump rate to calculate turnover rates.
|
|
|
Item No.:
16
|
|
Site:
Galley-Blast Chiller
|
|
Violation:
One, 4-inch hotel pan of GrieB Cream (made with milk and butter) was placed into the blast chiller at 08:35 at an internal temperature of 82°C and recorded on the cooling log. At 10:25, the temperature was taken and recorded at 18°C on the log. At 13:20, the temperature was 21°C in the middle of the pan when measured by the inspector. The product was discarded.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
19
|
|
Site:
Galley-Pastry/Bakery
|
|
Violation:
A heavy and significant accumulation of frozen condensate was observed in Walk-in Freezer 943. Several hotel pans of food were covered in a thick layer of frozen condensate. The hotel pans had a plastic wrap covering protecting the stored food and the frozen condensate did not appear to impact the food. All the surfaces of the storage shelves, including the posts and underneath the each shelf, was also covered with a thick layer of frozen condensate.
|
|
Recommendation:
Protect food from contamination by storing the food: (2) In a clean, dry location; and (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
19
|
|
Site:
Galley-Frozen Store 940
|
|
Violation:
Frozen condensate and ice were accumulating on the storage shelves and stored hotel pans. The bottom of the storage shelves had a layer of ice and frozen condensate, and packaged food was stored directly on top. Several hotel pans of food also had frozen condensate on the outside and on top of the stored packaged food. No condensate appeared to impact the prepackaged food and no food was discarded.
|
|
Recommendation:
Protect food from contamination by storing the food: (2) In a clean, dry location; and (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
20
|
|
Site:
Galley-Pizzeria Show Galley- Pizza Oven
|
|
Violation:
The stone cooking surface in the bottom oven had was pitted and had large cracks in several areas, making cleaning difficult.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
|
Item No.:
20
|
|
Site:
Buffet-Weite Welt Forward Beverage Station
|
|
Violation:
The far left soda dispensing unit had exposed slotted fasteners on the underside by the dispensing nozzle.
|
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Weite Welt Asian Outlet
|
|
Violation:
The decorative red covers for the light fixtures on the crew side of the buffet line were difficult to clean. Some of the red covers had an accumulation of dust on the top and in the opening on the bottom.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 10 Galley Locker
|
|
Violation:
The storage shelves in this area were made of galvanized metal that had several difficult to clean features and were used to store clean food equipment. This was noted on the previous inspection. The ship was in the process of ordering new shelves.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Galley-Warewash
|
|
Violation:
The vertical final rinse manifold pipe on the left side of the rack-type dishwash machine was heavily soiled with food debris.
|
|
Recommendation:
Ensure warewashing machines are cleaned: (1) before use; (2) throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; (3) at least every 24 hours (if used).
|
|
|
Item No.:
22
|
|
Site:
Galley-Pot Wash
|
|
Violation:
The mechanical potwash machine was out of order since the morning of the inspection. By the afternoon when the inspection team was in the area, the soiled pots and pans had accumulated to a point where some were staged in the main galley. Soiled equipment was on a trolley in front of the blast chiller and another trolley was up against the preparation counter in front of the blast chiller. No food preparation was taking place on this counter.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Weite Welt Aft Warewash
|
|
Violation:
The rack-type mechanical glass wash machine was out of service since 26 August. This was noted on the previous inspection. Staff stated the spare parts were ordered from Germany.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
23
|
|
Site:
Food Service General-Wash Temperatures
|
|
Violation:
The wash temperatures in most of the rack-type mechanical dishwash machines was below the minimum required 71°C specified on the data plate when measured by the inspector and crew. The wash temperature in Bella Vista dishwash machine was at 63°C; in the aft Weite Welt dishwash was at 67°C; in the forward Weite Welt dishwash was at 68°C; in the Deck 9 Markt dishwash was at 59°C; and in the Crew dishwash was at 66°C
|
|
Recommendation:
Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (2) 66°C (150°F) for a stationary-rack, dual-temperature machine; (3) 71°C (160°F) for a single-tank, conveyor, dual-temperature machine; (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine. Ensure a warewashing machine and its auxiliary components are operated in accordance with the machine?s data plate and other manufacturer?s instructions.
|
|
|
Item No.:
27
|
|
Site:
Buffet-Weite Welt Asian Outlet
|
|
Violation:
The decorative red covers for the light fixtures on the crew side of the buffet line were difficult to clean. Some of the red covers had an accumulation of dust on the top and in the opening on the bottom.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Galley-Weite Welt Cold Galley
|
|
Violation:
The top three shelves in the dry store cabinet next to the soda dispensing cabinet were soiled with an accumulation of food debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of food residue.
|
|
|
Item No.:
27
|
|
Site:
Galley-Markt Show Galley
|
|
Violation:
The potable water supply line to the combination oven was heavily soiled with grease and debris.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
30
|
|
Site:
Galley-Markt Health Station
|
|
Violation:
The handwash station was out of order for one week. The three-faucet handwash sink by the warewash was within 8 meters from most locations in the outlet.
|
|
Recommendation:
Keep handwashing facilities in good repair.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Markt Restaurant
|
|
Violation:
The deckhead above the waiter stations and buffet islands was open to the plenum between perforated panels. This was noted on the previous inspection. The ship was in the middle of addressing this issue.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Frozen Store 940
|
|
Violation:
Frozen condensate and ice were accumulating on the storage shelves and stored hotel pans. The bottom of the storage shelves had a layer of ice and frozen condensate, and packaged food was stored directly on top. Several hotel pans of food also had frozen condensate on the outside and on top of the stored packaged food. No condensate appeared to impact the prepackaged food and no food was discarded.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Pastry/Bakery
|
|
Violation:
A heavy and significant accumulation of frozen condensate was observed in Walk-in Freezer 943. Several hotel pans of food were covered in a thick layer of frozen condensate. The hotel pans had a plastic wrap covering protecting the stored food and the frozen condensate did not appear to impact the food. All the surfaces of the storage shelves, including the posts and underneath the each shelf, was also covered with a thick layer of frozen condensate.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Weite Welt Forward Warewash
|
|
Violation:
Water was leaking from the rack-type mechanical dishwash machine under the clean exit landing and pooling on the deck.
|
|
Recommendation:
Ensure decks in warewashing areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 10 Galley Locker
|
|
Violation:
The deck/bulkhead junctures around this room were not coved. This was noted in the previous inspection. Staff had a plan to install coving.
|
|
Recommendation:
Cove all bulkhead/deck junctures in food areas.
|
|
|
Item No.:
35
|
|
Site:
Galley-Weite Welt Forward Warewash
|
|
Violation:
Water was leaking from the rack-type mechanical dishwash machine under the clean exit landing and pooling on the deck.
|
|
Recommendation:
Ensure gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Weite Welt Asian Outlet
|
|
Violation:
The decorative red covers for the light fixtures on the crew side of the buffet line had an opening on the bottom which would allow broken glass to exit if the light bulb broke. The light bulb installed was not shatter-resistant.
|
|
Recommendation:
Ensure light bulbs are shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils, and linens, or unwrapped single-service and single-use articles.
|
|
|
Item No.:
39
|
|
Site:
Galley-Weite Welt Cold Galley
|
|
Violation:
One small fruit fly was in the dry store cabinet next to the soda dispensing cabinet.
|
|
Recommendation:
Effectively control the presence of insects in the food areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry/Bakery
|
|
Violation:
One live house fly was observed in this area.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Markt Juice Station
|
|
Violation:
Two small fruit flies were observed by the juice dispenser.
|
|
Recommendation:
Effectively control the presence of insects in the food areas aboard a vessel.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Delivery Inspections
|
|
Violation:
The incoming non-food items, i.e. engine room supplies, are not being inspect for pest on delivery.
|
|
Recommendation:
Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Other-Outbreak Prevention and Response Plan
|
|
Violation:
The OPRP did not list a procedure on how crew members would be notified of an outbreak when the ship enters an outbreak situation on Level Red. Revision of the corporate-provided procedure is in progress.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
|
|