Cruise Ship: AIDAVITA Cruise Line: Aida Cruises Inspection Date: 12/18/2015 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Potable Water-Microbiological Monitoring Records
Violation: For the company created logs of microbiological testing in both bunkering potable water and for the four random samples from the ships distribution network each month the option given is simply positive or negative. Staff complete that but do not identify that the result is for total coliforms or E. coli. Recommend the forms be changed in the results column so that it is clear what the result is for.
Recommendation: If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers? specifications.
Item No.: 10
Site: Recreational Water Facilities-Pool and Whirlpool Spa Monitoring Records
Violation: The pool and whirlpool spa data logging records were very hard to review because the data is recorded from approximately 6 am to midnight each day. Within nearly every day reviewed there were periods where the water chemistry was out of the required range, but there were no notations in the data sheets to understand precisely when each recreational water facility was open for use.
Recommendation: Include some notation on a log or on the paper record to indicate the opening and closing times for the RWF's.
Item No.: 30
Site: Food Service General-Handwash Stations
Violation: The sensor model paper towel dispensers throughout the vessel were slow to respond, particularly when a section of paper towel was delivered and another was triggered. Each sensor seemed to be different in its performance and most of the dispensers provided a very small single sheet of 300 mm or less. Most staff were observed using that single sheet and not fully drying their hands. The shortest paper towel was in the pool grill foyer, which delivered a section of less than 150 mm, Staff repaired this immediately during the inspection.
Recommendation: Make the needed adjustments to the paper towel dispensers so that the sheets provided are of a size where staff do not have to repeatedly trigger the sensor to produce several paper towels to dry hands.
Item No.: 21
Site: Buffet-Calypso Aft - Juice, Tea, and Beer Dispensers
Violation: The undercounter technical compartments for the juice station had gaps along the pipe penetrations thru the interior side and back panels. In the tea station and beer station there were large open voids where the cables passed thru the undercounter technical compartment back interior panels.
Recommendation: Seal seams and profile gaps. Open voids should be closed with large panels.
Item No.: 21
Site: Buffet-Calypso Aft - Soda Dispenser
Violation: The space behind the soda dispenser was only 50 mm before the bulkhead, which left almost no possibility to clean behind the unit.
Recommendation: Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead.
Item No.: 27
Site: Buffet-Calypso Aft - Soda Dispenser
Violation: The counter behind the soda dispenser was heavily soiled with dirt and debris.
Recommendation:
Item No.: 20
Site: Buffet-Calypso - Show Galley
Violation: There were gaps present below the steel profile strips installed along the three sides of each of the flat grill food-contact surfaces. The use of profiles and sealant behind the profiles on these cooking surfaces is not a correct design for food-contact and consideration should be given to replacing these wherever they exist on the ship.
Recommendation: Ensure food-contact surfaces of food equipment complies with American National Standards Institute (ANSI), National Sanitation Foundation International (NSF International), or other internationally accredited food equipment sanitation standards for materials, design, and construction.
Item No.: 21
Site: Buffet-Calypso - Show Galley
Violation: Although a long metal screw is in place to try to hold the right undercounter refrigerated drawer on the #3 refrigerator, still there is a large gap around the entire perimeter of the door where warm air freely passes thru because it will not remain shut tightly.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 22
Site: Galley-Calypso Galley and Market - Dishwash Areas
Violation: For both the conveyor dishwash and conveyor glasswash machines in the Calypso galley the low final sanitizing rinse temperature alarm light at the clean end of each machine was not working. The same condition was found on the conveyor glasswash machine in the Market dishwash. The bulb was burned out.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 36
Site: Buffet-Crew Mess
Violation: The artificial light level was below 110 lux between the bulkhead and the back of the juice dispenser and post mix (soda) dispenser.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 22
Site: Other-Deck 3 Potwash
Violation: There was an overwhelming amount of soiled pots and pans stacked in this area, including one rack soiled and stationed next to the clean rack of pots at the entry door. The soiled trolley was within 150 mm of the clean rack and the rack had no side splash panel. Opposite the 4 compartment sink were stacks of soiled that extended to a point opposite from the final sanitizing sink and the clean landing table in positions within 1/2 meter of the potwash machine when closed. There was a single dish rack that had soiled items stacked and nearly in contact with it and again no side splash panel was installed on the side of that rack.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 39
Site: Preparation Room-Deck 3 Cold Galley
Violation: One live fruit fly was observed on the deckhead near to the in-use meat slicer.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Bar-Pool Bar and Ocean Bar
Violation: The front bar at the pool bar had a sail cloth deckhead construction that was not hard and had a heavy soil in the center underside. The deckhead in the ocean bar was one of wood beams and a soft woven cloth material between the wood beams.
Recommendation: The cloth type deckhead should be replaced with a durable and hard material which is easy to clean and non-absorbent.
Item No.: 22
Site: Pantry-Pool Bar Pantry
Violation: The undercounter dishwash machine did not have a data plate affixed to the machine and none was posted in the pantry.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 21
Site: Bar-Ocean Bar
Violation: Inside the undercounter technical compartment for the back bar port side utility sink there were three individual power cables penetrating the lower interior panel with no closure or profile to block any pest entry and close the penetration tight.
Recommendation: Profile closed the power cable penetrations in the undercounter technical compartment.