Cruise Ship: Azamara Journey Cruise Line: Azamara Cruises Inspection Date: 12/11/2015 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Surveillance Log
Violation: A passenger reported to the medical center on 10 December with one episode of diarrhea and was issued antidiarrheal medication. She was listed in the AGE survfeillance log as a nonreportable case. No notes were in the file indicating that the medical staff asked if the one episode of diarrhea was above normal for her. The patient had Alzheimer's disease and her husband, who was her main caregiver, brought her to the medical center after she had the one episode of diarrhea.
Recommendation: Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]).
Item No.: 02
Site: Medical-Crew Member Immediate Contact Followup
Violation: A crew member reported to medical on November 29 with AGE symptoms and was diagnosed as a reportable case. The 48-hour follow-up with his cabin mate was not conducted and there was no information in the file indicating whether he had been asked about other immediate contacts. The medical personnel responsible for this case received disciplinary action.
Recommendation: When any crew member (food or nonfood employee) meets the case definition for AGE, take the following actions with asymptomatic cabin mates and other immediate contacts: (1) restrict exposure to symptomatic crew member(s); (2) undergo a verbal interview with medical or supervisory staff, who will confirm their condition, provide facts and a written fact sheet about hygiene and handwashing, and instruct them to report immediately to medical if they develop illness symptoms; (3) complete a verbal interview daily with medical or supervisory staff until 48 hours after the ill crew members? symptoms began. Ensure that the first verbal interview is conducted within 8 hours from the time the ill crew member initially reported to the medical staff. If the asymptomatic immediate contact or cabin mate is at work, ensure that he or she must is contacted by medical or supervisory staff as soon as possible. Document the date and time of verbal interviews.
Item No.: 11
Site: Medical-Crew Member Reporting
Violation: A crew member experienced a headache and 4 episodes of vomiting on 3 December beginning at 1200 but did not report to the medical center until 1930. He did not work during this time but according to his 72-hour questionnaire, but he did go to the crew mess at 1920. According to his medical records, he thought he was sea sick and the medical staff stated that there were rough seas during this time. The crew member was counseled on reporting AGE symptoms.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work. Document in the medical file whether or not the ill crew member has immediate contacts.
Item No.: 02
Site: Medical-Crew Member Immediate Contact Follow-up
Violation: A crew member reported to medical on December 3 with AGE symptoms and was diagnosed as a reportable case. The 48-hour follow-up with his three cabin mates did not begin until December 4. In addition, there was no information in the file indicating whether he had been asked about other immediate contacts. The medical personnel responsible for this had received disciplinary action.
Recommendation: When any crew member (food or nonfood employee) meets the case definition for AGE, take the following actions with asymptomatic cabin mates or other immediate contacts: (1) restrict exposure to symptomatic crew member(s); (2) undergo a verbal interview with medical or supervisory staff, who will confirm their condition, provide facts and a written fact sheet about hygiene and handwashing, and instruct them to report immediately to medical if they develop illness symptoms; (3) complete a verbal interview daily with medical or supervisory staff until 48 hours after the ill crew members? symptoms began. Ensure that the first verbal interview is conducted within 8 hours from the time the ill crew member initially reported to the medical staff. If the asymptomatic immediate contact or cabin mate is at work, ensure that he or she must is contacted by medical or supervisory staff as soon as possible. Document the date and time of verbal interviews. Document in the medical file whether or not the ill crew member has immediate contacts.
Item No.: 07
Site: Potable Water-Pipe Replacement Disinfection
Violation: Between October 9 and November 25, 2015, seven sections of copper piping were replaced with new plastic George Fisher piping. The disinfection records indicated that all pipes were disinfected with the emergency procedure of 200 ppm chlorine for 1 hour even though this replacement was not an emergency. The printed forms and procedures all indicated that 200 ppm chlorine for 1 hour should be used instead of the 50 ppm for 4 hour procedure required for routine/planned pipe replacements. An email was sent by the Chief of VSP to all cruise line public health departments on October 9, 2015 stating that using the emergency disinfection procedures for planned/routine pipe replacements was not allowed and should not be done.
Recommendation: Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
Item No.: 44
Site: Potable Water-Pipe Replacement Disinfection
Violation: Between October 9 and November 25, 2015, seven sections of copper piping were replaced with new plastic George Fisher piping. The disinfection records indicated that all pipes were disinfected with the emergency procedure of 200 ppm chlorine for 1 hour even though this replacement was not an emergency. The printed forms and procedures all indicated that 200 ppm chlorine for 1 hour should be used instead of the 50 ppm for 4 hour procedure required for routine/planned pipe replacements. An email was sent by the Chief of VSP to all cruise line public health departments on October 9, 2015 stating that using the emergency disinfection procedures for planned/routine pipe replacements was not allowed and should not be done.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 08
Site: Potable Water-Pipe Replacement Disinfection
Violation: Seven sections of pipe were replaced between October 9 and November 25, 2015. The records indicated that after disinfection the pipes were flushed with potable water. However, there was no documentation that the free halogen residual was tested or recorded to ensure it was below 5 ppm.
Recommendation: Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Engine Room
Violation: There was a leak from the pressure relief vent for the reduced pressure assembly on the potable water fill line for the whirlpools.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 19
Site: Provisions-Deck 2 Outside Bread Freezer and Ice Cream Freezer
Violation: Two pallets of bottled water were stored in this area next to boxes labeled 'PA system,' large black industrial cases, and a pallet jack. Staff stated that the cases contained tools for the upcoming dry dock. Bottles of water were in direct contact with the boxes, cases and pallet jack. The staff in the area was instructed by the inspector to move the pallets of water to a more appropriate storage area. When another inspector returned to the area later, the bottled water was still stored in the same location and a soiled leather tool bag and soiled voltmeter were on top of the bottled water. The tools were in use by a crew member repairing a pallet jack.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 28
Site: Provisions-Deck 2 Outside Bread Freezer and Ice Cream Freezer
Violation: A toaster was stored directly on the deck outside the electrician's workshop. Staff stated that the toaster needed repair.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 38
Site: Provisions-Deck 2 Outside Bread Freezer and Ice Cream Freezer
Violation: A jacket had been hung on the top of a shelf containing boxed plastic beer kegs. The jacket was not in contact with the stored beverages.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 33
Site: Provisions-Deck 2 Outside Bread Freezer and Ice Cream Freezer
Violation: The deck in this area was soiled. Two pallets of water and a toaster were stored in this area.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 19
Site: Housekeeping-Deck 8 Flower Shop Pantry Across from Cabin 8012
Violation: A bottle of champagne was stored on the counter. This pantry was used for storage and preparation of flowers and contained many vases, tools, and other flower arranging equipment.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 39
Site: Galley-Deck 4 Meat Preparation
Violation: Two fruit flies were observed in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Deck 4 Meat Preperatrion
Violation: Two exhaust vents in the deckhead were ajar with a 1 cm gap into the void above.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 29
Site: Galley-Deck 4 Dishwash
Violation: The water temperature in the left faucet of the two-faucet handwash station in this area was 131°F.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 20
Site: Food Service General-Ice Machines
Violation: Four ice machines inspected contained a slotted fastener in the food splash zone on the ice thickness sensor. The ice machines inspected were in the main galley, pool grille pantry, pool bar pantry and the looking glass pantry. A similar item was noted on the previous inspection in two deck pantries.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 22
Site: Galley-Deck 4 Dishwash
Violation: The data information display was flashing with a red alert button on the dishwash machine when the inspector first arrived in the area with the message 'insufficient water'. The green and amber alarm light on the machine was not working. Staff working the area did not know what the insufficient water alarm was for and no action had been taken.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 13
Site: Galley-Deck 4 Dishwash
Violation: The data information display was flashing with a red alert button on the dishwash machine when the inspector first arrived in the area with the message 'insufficient water'. The green and amber alarm light on the machine was not working. Staff working the area did not know what the insufficient water alarm was for and no action had been taken.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
Item No.: 26
Site: Galley-Deck 4 Potwash
Violation: Two large rectangular previously washed cake forms contained food residue. The stack of four items were removed for rewashing.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 34
Site: Galley-Deck 4 Potwash
Violation: The handwash station drain at the dirty end of the potwash was leaking and pooling on the deck.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 33
Site: Galley-Deck 4 Hot Galley
Violation: The grout was in disrepair.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Galley-Deck 4 Hot Galley
Violation: The bulkhead behind the two deep fat fryers had a buildup of oil and food debris greater than one day's accumulation.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Staff Mess
Violation: The deck under the buffet service had a area buildup of dust and food debris greater than one day's accumulation.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Deck 3 Dishwash
Violation: The data plate on the in use flight-type conveyor dishwash in this area specified pressure between 15 to 25 psi for the final sanitizing rinse. The pressure gauge read 12 psi. This was corrected.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 33
Site: Galley-Deck 3
Violation: The deck in this area was stained and soiled beyond one day's accumulation of debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 19
Site: Provisions-Meat Freezer
Violation: Nonpotable ice for carving was stored directly on the deck and food items in a white Styrofoam cooler labeled lime leaves was stacked directly on the ice.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 16
Site: Buffet-Deck 9
Violation: During breakfast, eggs were served sunny side up on the buffet. The consumer advisory posted at this station did not state that these eggs were served undercooked.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order.
Item No.: 39
Site: Galley-Deck 9 Windows
Violation: One fruit fly was observed in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Deck 9 Windows
Violation: The undercounter refrigerator across from the grill was leaking water from underneath and pooling on the deck. The source of the water was not determined.
Recommendation: Ensure water does not leak and pool on the deck.
Item No.: 33
Site: Galley-Deck 9 Windows
Violation: The deck under the preparation area was soiled with food and debris of more than one day's accumulation.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Galley-Deck 9 Windows
Violation: The sanitizing bucket in this area was soiled with a dirty, oily sheen.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 22
Site: Galley-Deck 9 Potwash
Violation: The glasswash machine was out of order, which caused an excessive amount of dirty dishes to accumulate on the surrounding counters after breakfast.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use. Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 16
Site: Dining Room-Deck 9 Pool Grill
Violation: The cheese burger and the Azamara burger could be cooked to order but these items on the menu did not have asterisks to link the food items to the consumer advisory.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 20
Site: Galley-Deck 9 Pool Grill
Violation: The grill had a heavy bead of dirty and pealing silicone in the food-splash zone where it joined the counter.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
Item No.: 26
Site: Galley-Deck 9 Pool Grill
Violation: The grill had a heavy bead of dirty and pealing silicone in the food-splash zone where it joined the counter.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Galley-Deck 9 Pool Grill
Violation: A used plastic glove was under previously cleaned cream pitchers stored in a dish wash rack. The glove was directly contacting three pitchers and there were approximately 30 pitchers stored in this rack. The glove appeared to have been turned inside out when it was removed from the user's hand.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 27
Site: Galley-Deck 9 Pool Grill
Violation: There was black food debris in the previously cleaned drip tray housing in the front of the grill.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 39
Site: Provisions-Vegetable Preperation
Violation: Two fruit flies were observed in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 35
Site: Galley-Deck 4 Potwash
Violation: The handwash station drain at the dirty end of the potwash was leaking and pooling on the deck.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 33
Site: Provisions-Meat Freezer
Violation: Nonpotable ice for carving was stored directly on the deck.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.