Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Costa Deliziosa Cruise Line: Costa Crociere S.P.A. Inspection Date: 12/21/2015 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: The spray pattern in the upper spray arm of the auxlilary rinse of the in-use conveyor dishwashing machine produced a weak single stream of water that did not cover the entire surface of the dishes passing under. There was also one final sanitizing spray nozzle on the far right of the upper spray arm that was partly clogged. Staff repaired the machine during the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 21
Site: Galley-Main Galley - Hot Galley
Violation: When fully closed there was a gap at the lower half of the right door of undercounter three door refrigerator #11190.01. The gap was between the door gasket and door frame and it was large enough to pass a set of folded papers in and out of the refrigerator.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 16
Site: Galley-Crew Galley - Hot Galley
Violation: At 10:20 am two pans of cooked rice were found stored inside the cook and hold oven #1, which was labeled for time control. The time control plan listed the set-up time for lunch as 10:45 am, with the meal starting at 11:00 and finishing at 1:00 pm. There was also a pan of cooked soup setting on a counter with a 2:15 pm discard time label affixed. The staff were not clear on the fact that the time plan should match the operations, as there was no notations provided on the plan that the times were changing today. It also seemed the staff considered the start of time control as the point of set-up, rather than when the food is moved away from temperature control.
Recommendation: Ensure staff review the time control plans and follow the specific times for time control which start when foods are removed from temperature control and end at the 4 hour discard.
Item No.: 39
Site: Buffet-Crew Mess - Buffet Line
Violation: There were four live fruit flies found this area, including: two on the bulkhead near the handwash station, one on the deckhead near the exhaust vent cover at the center of the buffet line, and one near the supply air vent cover at the end of the buffet line.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Buffet-Crew Mess - Buffet
Violation: The deck below the ice cream vending machine was soiled with dirt debris and one bread roll.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 39
Site: Provisions-Buffet Preparation Room
Violation: There were 6 live fruit flies observed on deckhead panel seams throughout this space, which was in operation at the time of inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Preparation Room-Provisions - Bakery
Violation: There were two live fruit flies observed on the deckhead near the entry door and four more live fruit flies on the deckhead and bulkhead at panel seams over the dough sheeter. The area was in active food preparation at the time of inspection.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 20
Site: Preparation Room-Provisions - Vegetable Preparation
Violation: Among the clean cutting boards were two green board which was heavily scored along the surface and at least one yellow board with plastic fibers extending away from the surface. All three boards were in need of re-surfacing.
Recommendation: Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 39
Site: Galley-Lido Galley - Cold Galley
Violation: There were two live fruit flies observed on the deckhead in the center of the room during active preparation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Buffet-Lido Buffet - Main Line Starboard
Violation: One live filth fly was observed on the deckhead over the center section of the sellf-service buffet line.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 08
Site: Potable Water-Bunker Stations
Violation: In the port aft bunker station, the keeper chains for the bottom two potable water filling lines were not attached to the screw caps. In addition, the screw cap for the middle filling line was not in place and was found face down on the top of the fuel filling line. The cap was sanitized and replaced and the keeper chains were attached. In the starboard aft bunker station, the keeper chain for the bottom potable filling line was not attached. This was corrected.
Recommendation: Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
Item No.: 10
Site: Housekeeping-Cabin Whirlpools
Violation: The cabin whirlpools were sanitized on 3 December and then on 11 December, instead of 10 December. The water to the cabins was shut off between 0800 and 1600 on 10 December for maintenance.
Recommendation: Clean and disinfect private whirlpool spas located in individual passenger cabins, including associated recirculation systems, between occupancies or weekly, whichever is more frequent. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program