Item No.:
07
|
|
Site:
Potable Water-Pipe Superchlorination
|
|
Violation:
Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
|
|
Recommendation:
Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Starboard Bunker Station
|
|
Violation:
The center potable water filling line was open and had its cap resting on top of the line. The filling line was immediately closed.
|
|
Recommendation:
Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Pipe Superchlorination
|
|
Violation:
Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
|
|
Recommendation:
Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
|
|
|
Item No.:
14
|
|
Site:
Galley-Bakery
|
|
Violation:
A crew member working with dough had a thick mustache and was not wearing a hair restraint.
|
|
Recommendation:
Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
|
|
|
Item No.:
19
|
|
Site:
Buffet-La Terrazza
|
|
Violation:
On two platters, the serving utensil handle was in contact with the bread.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The wash tank was soiled with food debris.
|
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
|
Item No.:
23
|
|
Site:
Galley-Port Dishwash
|
|
Violation:
The in-use dishwash machine wash tank temperature measured 137°F. The manufacturer's data plate stated a minimum temperature of 150°F. Later during the inspection the tank temperature was increased to a proper temperature.
|
|
Recommendation:
Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
|
|
|
Item No.:
28
|
|
Site:
Other-Durable and Consumable Locker
|
|
Violation:
Some chinaware, single-service, and single-use utensils were stored in open boxes. The deckhead had exposed pipes and cables. During the inspection, crew members were in the process of sealing the boxes.
|
|
Recommendation:
Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
30
|
|
Site:
Buffet-La Terrazza
|
|
Violation:
The handwash station soap dispenser was not providing a sufficient amount of soap. The dispenser was replaced with one that operated properly.
|
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
|
Item No.:
33
|
|
Site:
Other-Durable and Consumable Locker
|
|
Violation:
Some chinaware, single-service, and single-use utensils were stored in open boxes. The deckhead had exposed pipes and cables.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
39
|
|
Site:
Galley-Pastry Potwash
|
|
Violation:
One fly was in this area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-La Terrazza
|
|
Violation:
One fly was in both the potwash area and the dishwash area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Incoming Supplies
|
|
Violation:
There was no documentation of the inspection of nonfood items prior to being brought onboard.
|
|
Recommendation:
Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Mooring Lines
|
|
Violation:
The rat guards were not effective in preventing rodents from entering the ship. The wind had blown off most of the guards from the mooring lines. A few guards only had the U-shaped piece resting on top of the line and were not closed off around the line.
|
|
Recommendation:
Protect entry points where pests may enter the food areas.
|
|
|
Item No.:
44
|
|
Site:
Potable Water-Pipe Superchlorination
|
|
Violation:
Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
|
|
Recommendation:
Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|