Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 01/05/2016 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 07
Site: Potable Water-Pipe Superchlorination
Violation: Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
Recommendation: Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
Item No.: 08
Site: Potable Water-Starboard Bunker Station
Violation: The center potable water filling line was open and had its cap resting on top of the line. The filling line was immediately closed.
Recommendation: Ensure the potable water filling line has a screw cap fastened by a noncorroding cable or chain to an adjacent bulkhead or surface in such a manner that the cap cannot touch the deck when hanging free. Ensure the hose connections are unique and fit only the potable water hoses.
Item No.: 08
Site: Potable Water-Pipe Superchlorination
Violation: Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
Recommendation: Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
Item No.: 14
Site: Galley-Bakery
Violation: A crew member working with dough had a thick mustache and was not wearing a hair restraint.
Recommendation: Ensure food employees wear hair restraints and clothing that covers body hair. Ensure these items are designed and worn effectively to prevent hair from contacting exposed food; clean equipment, utensils, and linens; and unwrapped single-service and single-use articles.
Item No.: 19
Site: Buffet-La Terrazza
Violation: On two platters, the serving utensil handle was in contact with the bread.
Recommendation: During pauses in food preparation or dispensing, ensure food preparation and dispensing utensils are stored: (1) In the food with their handles above the top of the food and the container.
Item No.: 22
Site: Galley-Dishwash
Violation: The wash tank was soiled with food debris.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 23
Site: Galley-Port Dishwash
Violation: The in-use dishwash machine wash tank temperature measured 137°F. The manufacturer's data plate stated a minimum temperature of 150°F. Later during the inspection the tank temperature was increased to a proper temperature.
Recommendation: Ensure the temperature of the wash solution in spray type warewashers that use hot water to sanitize is not less than: (4) 66°C (150°F) for a multi-tank, conveyor, multi-temperature machine.
Item No.: 28
Site: Other-Durable and Consumable Locker
Violation: Some chinaware, single-service, and single-use utensils were stored in open boxes. The deckhead had exposed pipes and cables. During the inspection, crew members were in the process of sealing the boxes.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 30
Site: Buffet-La Terrazza
Violation: The handwash station soap dispenser was not providing a sufficient amount of soap. The dispenser was replaced with one that operated properly.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 33
Site: Other-Durable and Consumable Locker
Violation: Some chinaware, single-service, and single-use utensils were stored in open boxes. The deckhead had exposed pipes and cables.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 39
Site: Galley-Pastry Potwash
Violation: One fly was in this area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-La Terrazza
Violation: One fly was in both the potwash area and the dishwash area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 40
Site: Integrated Pest Management-Incoming Supplies
Violation: There was no documentation of the inspection of nonfood items prior to being brought onboard.
Recommendation: Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections.
Item No.: 40
Site: Integrated Pest Management-Mooring Lines
Violation: The rat guards were not effective in preventing rodents from entering the ship. The wind had blown off most of the guards from the mooring lines. A few guards only had the U-shaped piece resting on top of the line and were not closed off around the line.
Recommendation: Protect entry points where pests may enter the food areas.
Item No.: 44
Site: Potable Water-Pipe Superchlorination
Violation: Since the beginning of 2015, staff was disinfecting pipe replacements with 50 ppm chlorine for 1 minute. No flushing or chlorine concentration after flushing was documented. There were approximately 20 disinfection jobs documented with this procedure, eight of which occurred since the last inspection in October 2015.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program