|
|
|
Item No.:
05
|
|
Site:
Potable Water-Far Point Calibration
|
|
Violation:
Several tests were made at the distant point chlorine analyzer for the potable water distribution system to compare the mounted chlorine analyzer values to the manual test kits. Throughout the tests the chlorine analyzer reading was 1.36 ppm. The initial tests from the inspector's kit were 0.55 and 0.62 ppm free chlorine residual, while the ship's manual kit registered 1.2 and 1.3 ppm. Another identical kit was used to verify the first kit, using the same sample water. Both kits had readings of 1.2 and 1.3 ppm. The kit instructions were reviewed and the inspector performed the test with both kits using the same sample vial throughout. The results were 0.5 and 0.4 ppm free chlorine. Staff used a glass vial with 10 ml of water and a 10 ml powder pack, when the plastic vial should have been used with 5 ml of water and 25 ml powderThe analyzer was re-calibrated.
|
|
Recommendation:
Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
06
|
|
Site:
Medical-Incubator for Microbiological Analysis
|
|
Violation:
There was a potable water sample inside the incubator and the temperature gauge displayed 37.5 °C. The water test kit manufacturer specifies incubation at no higher than 35.5 °C. Staff adjusted the temperature during the inspection.
|
|
Recommendation:
If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers? specifications.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Potable Water Tank Maintenance
|
|
Violation:
The 6-9 November spot painting of potable water tank 3 starboard and 14-17 October for potable water tank 5 port included a hard drying time according to the paint manufacturer's graph of 26 and 24 hours respectively. The manufacturer also included a graph for curing times, with a description that 75% of the time given for full tank painting was to be used for the curing of the paint. Using that graph and the temperatures of 25 °C for the tanks which were painted would result in at least 4 days of curing before the tanks were finally disinfected and filled again.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
|
|
|
Item No.:
08
|
|
Site:
Ventilation-AC Fan Room #5710
|
|
Violation:
The potable water hose connection in the AC fan room #5710 was not striped or painted to indicate it was potable water.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Manual Test Kit
|
|
Violation:
The ship's manual test kit measures free and combined chlorine and pH, but it does not measure total alkalinity. Additionally, the ship did not have secondary standards on board to verify the test kit values for accuracy. Staff stated that the secondary standard solutions were on board, but expired. New standards were due for delivery during the ship's time in San Diego.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates. Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Main Pool
|
|
Violation:
The rescue or shepherd;s hook at the pool was approximately two meters too short to reach the center bottom of the pool from either side.
|
|
Recommendation:
Ensure the pole of the rescue or shepherd?s hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Plans
|
|
Violation:
The staff confirmed that time only as a public health control was used throughout the crew galley, both crew messes, and officer's mess, but there was no written plan in any of these areas posted.
|
|
Recommendation:
If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control.
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-Time Control Elements
|
|
Violation:
In the crew galley the cabinets below the bain marie counter were used for time control hot food holding, but none of them had labels affixed stating time control. The time control plans in the main galley and lido pantry did not identify the units where time control was practiced. Staff were observed using time control with pans of cooked penne pasta, tuna, and cut tomato on counters in the main galley soup station and counters were not mentioned in the plans and the pans were not labeled with discard times. Lastly, the main galley blast chiller had a time control label affixed to the front.
|
|
Recommendation:
List all equipment and places where time control is use, including counters, on the time control plan, then for equipment with closed compartments (not bain maries, cold basins, counters or soup wells) where time control is used apply labels stating time control permanently on that equipment or compartments. Remove time control labels from the blast chiller, and for loose pans of potentially hazardous foods placed on counters, loose tables, or trolleys, provide discard time labels on the individual pans of food, even if the service period is within 4 hours.
|
|
|
Item No.:
20
|
|
Site:
Galley-Blast Chiller
|
|
Violation:
The blast chiller was in disrepair and had been in this condition since September when this ship was taken over.
|
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines; and (2) Cutting or piercing parts of can openers must be kept sharp to minimize the creation of metal fragments that can contaminate food when the container is opened.
|
|
|
Item No.:
20
|
|
Site:
Galley-Main Galley - Bakery/Pastry
|
|
Violation:
The double belt dough sheeter in use had two heavy cloth/felt belts, which were woven and had difficult to clean fibers protruding from them.
|
|
Recommendation:
Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Other-Lido Grill
|
|
Violation:
There was a damaged and loose upper interior panel inside the flat grill grease pan housing that exposed a large open void outside of the housing.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Dining Room-Berlin Dining Room Buffets
|
|
Violation:
In both buffet counters in the dining room there were large open voids at the end sections where the internal construction of the plate lowering station connected with the foundation of the lower buffet counter.
|
|
Recommendation:
Panel profile the interior void spaces to prevent insect entry and harborage. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Main Galley - Cold Galley
|
|
Violation:
There was a gap present between the lower door gasket and door frame when shut that was large enough for a set of folded papers to pass from outside to inside of undercounter reach-in refrigerators 22, 23, 24, and 25.
|
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Crew Messes
|
|
Violation:
There was a difficult to clean gap present between the bulkhead and the back of both buffet counters in both of the crew messes. There was also a difficult to clean gap behind two door reach-in refrigerator #1 and the bulkhead.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The power cables to the back bar coffee machine were draped on the counter making cleaning difficult.
|
|
Recommendation:
Elevate or shorten power cables to allow easy cleaning of surfaces below.
|
|
|
Item No.:
22
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The in-use conveyor dishwash machine had a very weak, single water stream, spray pattern in each of the upper and side spray nozzles in the final sanitizing rinse spray arms.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Preparation Room-Provisions
|
|
Violation:
The undercounter dishwashing machine was in disrepair since the ship was taken over in September, 2015.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Other-Lido Pantry - Dishwash
|
|
Violation:
There was no manufacturer's data plate affixed to the in-use stationary rack glasswashing machine.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
26
|
|
Site:
Galley-Main Galley - Bakery/Pastry
|
|
Violation:
Two small human hairs were found wedged in the top of two dough sheeter belts and there were food stains that appeared to be set in the surface of both belts. Staff were using the machine at the time of inspection.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-Lido Grill
|
|
Violation:
The interior of the flat grill grease pan housing was soiled with grease and food particles.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Preparation Room-Provisions
|
|
Violation:
The handwash station had a water temperature of 129 °F and could not be adjusted by the user. This was corrected during the inspection.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
29
|
|
Site:
Galley-Crew Galley Entry
|
|
Violation:
The handwash station at the entrance to the crew galley had a water temperature of 140.4 °F and could not be adjusted by the user. This was corrected during the inspection.
|
|
Recommendation:
Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
|
|
|
Item No.:
33
|
|
Site:
Buffet-Crew Messes
|
|
Violation:
The deck and bulkhead juncture was not coved in either of the two crew messes from the point beside the upright reach-in refrigerators to the bulkhead along the buffet counters and the beverage counter beside. This was corrected during the inspection.
|
|
Recommendation:
Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - Bakery/Pastry
|
|
Violation:
There were gaps at the bulkhead berhind the proofer oven where two pipes penetrated. Staff repaired these during the inspection.
|
|
Recommendation:
Install exposed utility service lines and pipes, including lines for fire detection and protection systems, so they do not obstruct or prevent cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
There was a heavy black dust accumulation in the exhaust vent directly above the conveyor dishwash machine.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Beverage Station
|
|
Violation:
The artificial light level behind the beverage dispensers on the counter was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Dishwash
|
|
Violation:
The artificial light level behind the conveyor dishwash machine was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Galley-Main Galley - Bakery/Pastry
|
|
Violation:
The artificial light level was below the minimum 110 lux behind the proofer.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Lido Buffet - Handwash
|
|
Violation:
The artificial light level at the handwash station on the crew side of the buffet was below the minimum 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
36
|
|
Site:
Other-Lido Pantry - Beverage Station
|
|
Violation:
There was less than 110 lux of artificial light behind the ice machine and behind the counter-mounted beverage equipment.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Messes
|
|
Violation:
In both crew messes the artificial light level at the buffet units and the adjacent beverage counters were below the minimum 220 lux. The artificial light level between the bulkheads and the upright two door reach-in refrigerators #1 and #2 were below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Pool Bar - Pantry
|
|
Violation:
The artificial light level behind the ice machine was below the minimum 110 lux.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
39
|
|
Site:
Galley-Main Galley - Hot Galley
|
|
Violation:
There was a live fruit fly observed at the counter beside the center handwash station in the hot galley.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
40
|
|
Site:
Other-Lido Pantry - Dishwash
|
|
Violation:
Opposite the soiled end of the dishwash and beside a closed dry store cabinet there was an insect electrocution device mounted to the deckhead. Inside this device were over 20 dead insects and remnants stuck on the internal wires and walls. The device was plugged in at the time of inspection. Staff removed the device from the area.
|
|
Recommendation:
Do not permit insect-control devices that electrocute or stun flying insects in food areas. Remove dead or trapped insects, rodents, and other pests from control devices and the vessel at a frequency that prevents their accumulation or decomposition or the attraction of other pests.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-Incoming Shipment Inspection Record
|
|
Violation:
There was good detail in the records for the pest inspection of food and non-food items delivered to the vessel at the pier, but the inspection of supplies arriving for the deck and engine departments for pests was not documented.
|
|
Recommendation:
Include in the records inspections of deck and engine department provisions to the ship.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-All 25 AC Fan Units
|
|
Violation:
Each AC fan unit has a small sight window cut into a panel where the fan coil is installed to see the condensate collection pan below, but the visual area that can be seen to check for cleanliness was only 150 mm deep and the pan length was over 1.5 meters. Staff did not have other methods, such as fiber optic cable to inspect the entire pan and to remove the large pipe to open the panel cover would take many hours.
|
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
|
|