Cruise Ship: Seadream II Cruise Line: Sea Dream Yacht Club Inspection Date: 03/19/2016 Inspection Score: 96
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Bar-Main Salon
Violation: In the technical space behind the compressor for the under counter refrigerator #2, a 8 cm x 8 cm opening to the void deck port side was found making the area difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Bar-Pool
Violation: The tile deck next to the bulkhead under the upright refrigerator #134A was in disrepair. It had a buildup of a white substance from the drain line above it.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 22
Site: Buffet-Top Side Buffet - Pantry #5
Violation: The hood type, stationary rack dishwash machine was out of order for the last two days according to staff.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Buffet-Top Side Buffet - Pantry #5
Violation: The stationary rack undercounter dishwash machine was in use and was reaching final sanitizing rinse temperatures of 157.8°F. The machine was re-tested after several more washings and reached 161°F at the dish level. It was unclear why the machine had to be operated thru so many wash cycles to reach these temperatures. Lastly, the data plate on the machine was missing the cycle times for all three cycles, and missing the final rinse cycle time.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 16
Site: Buffet-Top Side Buffet
Violation: The posted time as a public health control plan for this cold buffet did not list the undercounter reach-in refrigerators 1 and 2 as time control units and staff stated that are used for only time control foods. Additionally, these two refrigerators did not have labels affixed to the outside indicating they were for time control.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 16
Site: Galley-Top Side Galley - Hot Galley
Violation: Although most foods are prepared and served directly in this galley, there are some items the staff described some of the preparation requires time control in this hot galley and the time control plan did not list equipment for that purpose, such as the bain marie and the combination oven. As well, both this time control plan and the cold buffet plan should be reviewed and revised, as needed, to ensure they describe the flow of food from location (prep in main galley or prep in top side) and temperature control to the time control and discard end-points. The only food flow description on the hot galley plan was a description of the food flow in the main galley.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: A deck stand of soiled waiter trays was positioned on one side of the clean landing of the in-use conveyor dishwash machine that was nearly touching the landing table. On the opposite side of this same clean landing, within one meter, a loose table was stacked soiled dishware against the bulkhead at the clean end of the operation.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: The undercounter stationary rack glasswash machine did not have a manufacturer's data plate affixed to detail information such as the wash cycle or final sanitizing rinse cycle times or temperatures, and there was nothing posted in the area with that information.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 20
Site: Galley-Main Galley - Garde' Manger
Violation: Exposed interior wires, switches and boxes in the center of reach-in upright refrigerator #18 made cleaning difficult.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 20
Site: Galley-Main Galley - Hot Galley
Violation: A gap was found in the back interior panel of upright reach-in refrigerator #21, where the power cable penetrated the stainless steel panel. Staff repaired this gap during the inspection.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 33
Site: Galley-Main Galley - Hot Galley
Violation: The double deep fryers were mounted on legs only 100 mm above the deck, making the area below difficult to access and clean. A brown food residue was visible under this fryer and significant black mold at the bulkhead trim near the deck on the right side of the right fryer.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 19
Site: Buffet-Crew Mess - Rice Station
Violation: Two portable rice steaming machines were set at the bulkhead counter with one upper steamer for lunch self-service and the other on a shelf directly below the first as a back-up unit. No sneeze shield was provided for the crew self-service of this rice.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 06
Site: Potable Water-Far Point
Violation: On 02/21 and 03/14 there was an overlap halogen far point readings of dates and recordings were for over 24 hours. This resulted in the 2/22 and 3/15 chart records having halogen far point readings less than 16 hours in the 24-hour period.
Recommendation: Change, initial, and date halogen analyzer-chart recorder charts daily. Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
Item No.: 06
Site: Potable Water-Far Point
Violation: The record for 02/28 had more than 13 hours missing of free halogen due to a pen malfunction.
Recommendation: Maintain the halogen analyzer-chart recorder properly and operate it in accordance with the manufacturer?s instructions. Conduct a manual comparison test daily to verify calibration. Calibrate whenever the manual test value is greater than 0.2 ppm higher or lower than the analyzer reading. Ensure records from the halogen analyzer-chart recorder verifies the free residual halogen of between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24 hour period since the last inspection of the vessel.
Item No.: 10
Site: Recreational Water Facilities-Records
Violation: The pool and whirlpool records did not indicate the filter housing was cleaned and sanitized as required.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Pool Records
Violation: From 11/23/2015 until 02/06/2016, the halogen readings were manually recorded every 4 hours. On 12/30 only one halogen reading was recorded at opening and no other readings were recorded. New equipment was installed end of December, to include a salt generator and analyzer, but the monitoring analyzer system was not operational until after 02/06/2016.
Recommendation: Monitor and adjust the RWF?s flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry. Maintain and operate the halogen and pH analyzer-chart recorder in accordance with the manufacturer?s instructions. Conduct a manual comparison test before opening the RWF to verify calibration for free halogen residual and pH. Ensure the analyzer reading is within 0.2 ppm for free halogen and 0.2 for pH. For RWFs open longer than 24 hours, conduct a manual comparison test every 24 hours.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Records
Violation: From the whirlpool records 11/23-30, the pH and chlorine was manually recorded hourly because the whirlpool monitoring system was not working. The pH was recorded as over 7.8 for an hourly reading 7 different times. From the whirlpool records 12/01-09, the pH and chlorine was manually recorded hourly because the whirlpool monitoring system was not working. The pH was recorded as over 7.8 for an hourly reading 2 different times. Super chlorination was also not recorded on 12/15. On 12/22 the chlorine value was recording at opening as 9.8 ppm then increased to over 10 ppm from 0800 to 1100, as indicated on chart record. On 01/09, the chlorine value recording at opening was 9.95 and then increased to over 10 ppm from 11 am to 2 pm and 2:20-4:30 pm.
Recommendation: Monitor and adjust the RWF?s flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
Item No.: 07
Site: Potable Water-Skin Tanks
Violation: The variance for the skin tanks (dated 11/24/15) was submitted to VSP on the day prior to the inspection, and is in pending status. The 2007 variance letter and procedure were available for review as well as the revised variance dated 11/24/15. The conductivity log and calibration certificates were available for review and the ship is following the variance protocol.
Recommendation: Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
Item No.: 07
Site: Potable Water-Skin Tanks
Violation: In reviewing the skin tank variance documentation with the staff, it was discussed that one potable water tank on the aft had a hole. The two aft tanks, 8 port and 8 starboard, share a wall, so the ship is not using both of these tanks. These tanks are empty and have not been used in the past year. These tanks can be disconnected from the pump system and isolated from potable water storage and distribution system.
Recommendation: Ensure potable water tanks do not share a common wall with the hull of the vessel or with tanks or piping containing nonpotable water or other liquids.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Monitoring System
Violation: New equipment was installed at the end of December, including a salt generator and analyzer, but there were issues with the analyzer system. From 01/23-31 and 02/01-05, manual hourly recordings were recorded, as the monitoring analyzer system was not working.
Recommendation: Maintain halogenation and pH control systems in good repair and operate them in accordance with the manufacturer?s recommendations.