Item No.:
08
|
|
Site:
Potable Water-Production Piping
|
|
Violation:
The previously compliant blue-gray-blue striping on the permeate and distillate piping between the reverse osmosis and evaporator water production systems, prior to chlorination had the gray stripe covered over with a green stripe indicating that it was potable.
|
|
Recommendation:
Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-Far Point
|
|
Violation:
The far point chart for 26 FEB 2016 had a four hour overlap in the record where it had not been changed when it had completed the previous day's recording.
|
|
Recommendation:
Change, initial, and date halogen analyzer-chart recorder charts daily.
|
|
|
Item No.:
43
|
|
Site:
Ventilation-Drain Pan Inspection Accessibility
|
|
Violation:
The main air handling unit condensate pans on Deck 9 (AC/E 611) and Deck 7 (AC/E 623) and similar units, are not constructed to facilitate easy inspection. The inspection team did not have the tools to remove the many bolts and screws required to access these drain pans. Sight windows had not been installed to allow routine inspection of these areas.
|
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Lighting
|
|
Violation:
The light intensity was less than 110 lux behind and around counter-mounted and deck-mounted equipment, such as ice machines, ovens, and beverage equipment, in numerous food outlets. This included: housekeeping pantries, main galley, preparation rooms, ice cream bar and other service and preparation areas. The ship has a plan in progress to address these illumination issues. Work had been done since the previous inspection in the lido galley and the rest of the areas were to be addressed during the 2017 dry dock.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Deck 11
|
|
Violation:
Dust was accumulated in the deckhead gap between the yogurt and fruit stations at the galley entrance.
|
|
Recommendation:
Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Deck 11 Trident Grill
|
|
Violation:
The light intensity at the front counter was less than 220 lux.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 5 Port Beverage Station
|
|
Violation:
A small fly was in this area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
17
|
|
Site:
Galley-Deck 5 Cold Pantry Walk-in
|
|
Violation:
Two trays of sliced cheeses stored in the walk-in could not be located on the cooling log. One tray had a discard date of 3/31/16 and the other had a discard date of 3/30/16.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 5
|
|
Violation:
The light intensity was less than 220 lux where cleaning materials such as mops were stored behind the cleaning locker near Cold Store #52.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
24
|
|
Site:
Galley-Deck 5 Pot Wash Area
|
|
Violation:
The crew member at the clean end of the three-compartment sink was observed submerging the clean pans in the sanitizing solution for less than seven seconds. In addition, a crew member in the clean storage area took a pan from the crew member at the rinse sink without first sanitizing the pan. He proceeded to bring the pan to the clean storage racks before he was stopped by the inspector and the managers. When the inspector explained that the pan needed to be sanitized before it was placed in the clean storage area, he dipped the pan in the sanitizing sink and then immediately removed it without waiting for seven seconds.
|
|
Recommendation:
Ensure a chemical sanitizer is used in accordance with the EPA-approved manufacturer?s label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
13
|
|
Site:
Galley-Deck 5 Pot Wash Area
|
|
Violation:
The crew member at the clean end of the three-compartment sink was observed submerging the clean pans in the sanitizing solution for less than seven seconds. In addition, a crew member in the clean storage area took a pan from the crew member at the rinse sink without first sanitizing the pan. He proceeded to bring the pan to the clean storage racks before he was stopped by the inspector and the managers. When the inspector explained that the pan needed to be sanitized before it was placed in the clean storage area, he dipped the pan in the sanitizing sink and then immediately removed it without waiting for seven seconds.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
|
|
|
Item No.:
16
|
|
Site:
Galley-
|
|
Violation:
A pan of pesto pasta salad stored in the walk-in refrigerator had a discard date of 3/28/16. A review of the cooling logs indicated that the salad was prepared and cooled on 3/22/16, but the pasta was cooked and cooled on 3/21/16. Therefore, the discard date should have been 3/27/16.
|
|
Recommendation:
Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1.
|
|
|
Item No.:
13
|
|
Site:
Galley-
|
|
Violation:
A pan of pesto pasta salad stored in the walk-in refrigerator had a discard date of 3/28/16. A review of the cooling logs indicated that the salad was prepared and cooled on 3/22/16, but the pasta was cooked and cooled on 3/21/16. Therefore, the discard date should have been 3/27/16.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Crew Mess Beverage Station
|
|
Violation:
On the ice/water dispenser, the fastener behind the water dispenser was heavily corroded. Correction began while the inspection team was still in the area.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Officer's Mess
|
|
Violation:
A large fly was in the soiled dish storage area.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
08
|
|
Site:
Buffet-Dishwash Area
|
|
Violation:
The backflow prevention device on the rack-conveyor dishwash machine on the right was leaking continuously from the atmospheric vent. The device was replaced.
|
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
|
Item No.:
12
|
|
Site:
Provisions-Bonded Store 6
|
|
Violation:
And opened and partially consumed bottle of water was stored on a shelf next to bottled beverages. This was removed.
|
|
Recommendation:
Ensure employees eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and table linens; unwrapped single-service and single-use articles; or other items needing protection cannot occur.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Beer/Soft Drinks Store
|
|
Violation:
A box of bottles was on the deck. The crew member in the area stated that he placed it on the deck when transferring from one pallet to another. In addition, a large pile of discarded plastic wrap from the pallets was stored on top of an open box of bottled wine.
|
|
Recommendation:
Protect food from contamination by storing the food: (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
12
|
|
Site:
Provisions-Beer/Soft Drinks Store
|
|
Violation:
The crew member working in this area unloading boxes had an opened bottle of partially consumed water with him.
|
|
Recommendation:
Ensure employees eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and table linens; unwrapped single-service and single-use articles; or other items needing protection cannot occur.
|
|
|
Item No.:
13
|
|
Site:
Provisions-
|
|
Violation:
An opened and partially consumed bottle of water was stored on a shelf next to bottled beverages in Bonded Store 6. The crew member working the Beer/Soft Drinks Store unloading boxes had an opened bottle of partially consumed water with him.
|
|
Recommendation:
Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-
|
|
Violation:
The dispensing spout on the previously-cleaned juicer was soiled on the inside of the spout.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|