Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Balmoral Cruise Line: Fred Olsen Cruise Line Inspection Date: 05/03/2016 Inspection Score: 91
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 18
Site: Provisions-Meat Thawing Room
Violation: A large lexan container of ground beef was stored on top a lexan container of pork.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (2) Separating types of raw animal foods from each other such as beef, fish, lamb, pork, and poultry-except when combined as ingredients-during storage, preparation, holding, and display by using separate equipment for each type, or by arranging each type of food in equipment so that cross-contamination of one type with another is prevented, or by preparing each type of food at different times or in separate areas.
Item No.: 26
Site: Preparation Room-Poultry Area
Violation: Six previously cleaned large lexan containers and lids stored on the preparation counter were soiled with food debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Preparation Room-Poultry Area
Violation: The six lexan containers were stored wet in two stacks (3 lexan containers per stack) on the preparation counter. Water was pooled on the preparation counter around and in direct contact with the lexan containers and lids. It could not be determined if all the water on the counter was from the lexan containers or a previous operation. All six lexan containers and lids were removed to be rewashed.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 38
Site: Provisions-Galley Equipment Storage Room
Violation: Cleaning materials, including squeegees, a broom, and a floor buffer, were stored in the room along with food equipment. Staff stated some of the food equipment in this room was no longer used in the operation and was to be discarded.
Recommendation: Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
Item No.: 28
Site: Galley-Pot Wash
Violation: Four lexan containers were stacked wet on the clean storage rack and not allowed to properly air dry.
Recommendation: Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
Item No.: 36
Site: Buffet-Crew Mess Beverage Station
Violation: The light intensity behind and around the juice and coffee machines was less than 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 21
Site: Buffet-Crew Mess Beverage Station
Violation: The electrical cords for the coffee and juice machines were draped on the counter which makes cleaning difficult.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Buffet-Crew Mess Beverage Station
Violation: The counter under the juice and coffee machines was soiled with dust and debris. Water was pooled on the counter under the far right juice machine.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Buffet-Crew Mess Beverage Station
Violation: The deck under the beverage station and at the deck/bulkhead juncture was soiled with dust, dirt, and debris. The deck/bulkhead juncture was not coved. Three single-service sugar packets were stuck to the deck in water to the right of the beverage station.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel). Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 22
Site: Room Service-Dishwash Machine
Violation: When the final rinse was activated a burst of steam would exit from the clean end of the machine and the pressure gauge would rise to 35 psi for about 3 seconds then return to the normal operating range of 20 +/- 5psi.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Room Service-Dishwash Machine
Violation: The water temperature of the final rinse manifold was measured above 200°F during the first three seconds of activation when the water pressure would increase.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 38
Site: Preparation Room-Deck 5 Bakery
Violation: Cleaning supplies, such as squeegees and brooms, were hanging on hooks by the deck oven. A enclosed trolley with food items were stored against the cleaning supplies on the bulkhead. Disposable plastic aprons used by the bakery workers were also stored on the hooks with the cleaning supplies.
Recommendation: Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
Item No.: 14
Site: Preparation Room-Deck 5 Bakery
Violation: Disposable plastic aprons used by the bakery workers were stored on the hooks with the cleaning supplies.
Recommendation: Ensure food employees wear a clean uniform or apron to prevent contamination of food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 17
Site: Galley-Deck 6 Hot Galley
Violation: According to the cooling log, the cooling process for boiled eggs cooked on 2 May began at 10:11a when the eggs were at 31.5°C (88°F) and ended at 11:05a when the eggs reached 2.1°C (36 °F). According to staff, the eggs were boiled and then left out on the counter to cool to a temperature were staff could peel the shells off. The eggs were then placed in the blast chiller to finish cooling.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 16
Site: Galley-Deck 6 Room Service Pantry
Violation: A tray of potentially hazardous cold sandwiches were stored in mobile cart #1 on time control, but were not labeled with a discard time. The room service operation was open for more than 4 hours.
Recommendation: If time only-rather than time in conjunction with temperature-is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours.
Item No.: 17
Site: Galley-Deck 6 Cold Pantry
Violation: A cooling log entry for cut cantaloupe and cut watermelon cooled on 25 April did not have a final cooling temperature recorded.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 29
Site: Galley-Crew Toilet Room
Violation: The main toilet room door was open and the urinals were accessible, but toilet stall door was locked while the galley was in operation.
Recommendation: Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
Item No.: 17
Site: Galley-Pastry
Violation: No cooling logs were available for the whipped cream prepared the morning of the inspection. The whipped cream was stored in the walk-in refrigerator below 41°F.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 33
Site: Galley-Warewash
Violation: There was a gap around the sprinkler in the deckhead above the soiled end of the conveyer dishwash machine.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 26
Site: Galley-Beverage Area
Violation: Four toasters were stored soiled on the counter. The toasters were turned around so the front of the machines were pointed towards the bulkhead. Staff stated the toasters were used in the morning and then were turned around after use.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Beverage Area
Violation: The counter under the toaster in the corner of the counter was heavily soiled with dust and food debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 31
Site: Galley-Wine Room
Violation: Two hand pump containers of virucidal alcohol hand gel and one container of disinfectant wipes were stored on the same counter with food equipment.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 31
Site: Dining Room-Ballindaloch
Violation: A hand pump container of virucidal alcohol hand gel and a container of disinfectant wipes was stored on each waiter station in the main dining room. The dining room had approximately 14 waiter stations.
Recommendation: Store poisonous or toxic materials used in the cleaning and maintenance of food areas in a cleaning materials locker so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 38
Site: Galley-Palms
Violation: Cleaning equipment, such as squeegees and brooms, were stored on hooks on the bulkhead by the utility sink in the warewash area.
Recommendation: Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
Item No.: 27
Site: Buffet-Palms
Violation: The surface under the drip trays for the center grill on the employee side of the buffet was heavily soiled with grease and food debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-Avon/Spey
Violation: There was a hole in the bulkhead around a water pipe under the flat grill. It appeared the water line was no longer used.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Bar-Observatory Bar
Violation: The espresso machine was mounted to the counter with less than 100 mm (4-inches) clearance.
Recommendation: Ensure table-mounted equipment that is not easily movable is elevated on legs that provide at least a 100 mm (4-inch) clearance between the table and the equipment.
Item No.: 33
Site: Food Service General-Decks
Violation: The decks in several food areas were in poor repair, especially around drain scuppers and where equipment was mounted to the deck. Recessed and missing tile grout was also noted throughout the food areas. Several deck tiles in the crew galley were cracked and chipped, and in two locations water would seep-out from the deck tiles when stepped on.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 11
Site: Medical-Crew Member Late Reporting
Violation: A musician experienced gastrointestinal illness (GI) symptoms, one diarrhea, at 1200 on 18 April, but did not report to medical until 2026 that day when he experienced more GI symptoms. He ate lunch and dinner in one of the restaurants and worked from 1153-1259, 1653-1747, and 1918-2020. This crew member was re-trained.
Recommendation: When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: 02
Site: Medical-Food Questionairres
Violation: The 72-hour food questionnaire did not include all the data elements that appear in the questionnaire in Annex 13.2.2.
Recommendation: Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 01
Site: Medical-24-hour Gastointestinal Illness (GI) Report
Violation: The 24-hour GI report submitted on 27 April before arrival in Norfolk, VA stated 150 of 916 passengers were GI reportable cases. Upon review of the GI log it was determined three passengers that were already deemed reportable cases earlier in the voyage were included in the 150 count. The actual number of reportable passengers was 147.
Recommendation: Ensure the AGE report contains the following: (6) total numbers of reportable cases of AGE among passengers, including those who have disembarked because of illness-even if the number is 0 (zero reporting);
Item No.: 19
Site: Potable Water-Engine Room - Mineralizer
Violation: Approximately 20 bags of hydro-carbonate, used to soften the potable water, were stored on the deck next to the mineralizers. The bags were subject to contamination stored on the deck, and unknown lines were directly above these bags.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 08
Site: Potable Water-Pipe Disinfection Records
Violation: A record from 16 April stated the correct procedure for replacing and disinfecting a new potable water pipe, but the halogen residual value was not recorded after flushing and prior to pipe installation.
Recommendation: Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Tank Maintenance Record
Violation: A record for 1 March stated that the potable water tank 15 starboard had a painting curing time of 6 days, but upon review of the paint manufacturer's instructions the manufacturer recommended curing for 7 days at a temperature of 21°C.
Recommendation: Follow all manufacturers' recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (3) written documentation that the manufacturers' recommendations have been followed for application, drying, and curing.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The vessel was using Oxivir Five 16 Concentrate as a disinfectant for the soft surface cleaning. The OPRP states a 1:64 dilution will be used with a contact time of 5 minutes during normal and outbreak levels (codes green, yellow, and red). The ship was using a 1:16 dilution of Oxivir, as recommended by VSP and the manufacturer's reference sheet online, but had been using a 1:64 dilution prior to the ship's arrival to the U.S.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses);
Item No.: 17
Site: Galley-Deck 6 Pastry
Violation: No cooling logs for potentially hazardous food items such as cheese cakes, custard pastries, and crème brulee, were available before 30 April.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 16
Site: Galley-Deck 6 Hot Galley
Violation: Potentially hazardous food was set-up on time control in a mise-en-plase arrangement on the preparation counter, but the preparation counters were not identified on the posted time control plan for the area.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 28
Site: Preparation Room-Deck 5 Bakery
Violation: Cleaning supplies, such as squeegees and brooms, were hanging on hooks by the deck oven. A enclosed trolley with food items were stored against the cleaning supplies on the bulkhead. Disposable plastic aprons used by the bakery workers were also stored on the hooks with the cleaning supplies.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program