Cruise Ship: Safari Endeavour Cruise Line: Un-Cruise Adventures Inspection Date: 05/22/2016 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: The four potable water tanks were disinfected in October 2015. The halogen levels of the tanks after disinfection and before being placed back into service were not recorded.
Recommendation: Document the free halogen residual level.
Item No.: 08
Site: Potable Water-Bunkering Shore Side Test
Violation: For the month of May, the results of the halogen and pH levels from the shore side bunkering sample were not recorded.
Recommendation: Conduct a free halogen residual and pH test on the shore-side water supply before starting the potable water bunkering process to establish the correct halogen dosage. Record the results of the pretest and ensure they are available for review during inspections.
Item No.: 10
Site: Recreational Water Facilities-Hot Tub Safety Sign
Violation: The safety sign for the two hot tubs was missing the following information: cautions against use by individuals who are immunocompromised, individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure, and pregnant women, elderly persons, and children. Additionally, there was no caution against exceeding 15 minutes of exposure. This was written on the previous inspection.
Recommendation: In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 10
Site: Recreational Water Facilities-Hot Tub Antientrapment Protection
Violation: There was no documentation that the single, blockable suction fitting cover in each hot tub was certified as an antientrapment cover. In addition, there was no secondary antientrapment protection installed on the suction line, such as a safety vacuum release system or automatic pump shut off.
Recommendation: For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 10
Site: Recreational Water Facilities-Data Logger
Violation: The values recorded by the electronic data logger for the port and starboard hot tubs were not stored in a secure database and could be manipulated once downloaded to a spreadsheet. This was written on the last two inspections.
Recommendation: If an electronic data logger is used in lieu of a chart recorder, ensure it has certified data security features.
Item No.: *
Site: Recreational Water Facilities-Data Logger
Violation: It was discussed that the electronic data logging could be in increments of 15 minutes.
Recommendation:
Item No.: 10
Site: Recreational Water Facilities-Hot Tub Shock Halogenation
Violation: Since the beginning of the Alaska season in May, the starting time and concentration, as well as the ending time and concentration were not being consistently recorded for the daily shock halogenation of the port hot tub. On 5 May, the start time and concentration was recorded at above 25 ppm, and approximately one hour later, the ending concentration was recorded at 6.62 ppm. There was no action indicated for the concentration being less than 10 ppm. On 8 May, the starting concentration and time was recorded, but the concentration at the end was not. For 12-22 May, no shock halogenation was recorded. The starboard hot tub was out of service for this time. A similar violation was written on the previous inspection.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Strainer and Housing Disinfection
Violation: Since the beginning of May, there was no record of the weekly disinfection of the hair and lint strainer and housing disinfection for the port hot tub. This was written on the previous inspection. The starboard hot tub had been out of service during this time.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Hot Tub Cartridge Filter
Violation: Since the beginning of May, the records indicated that the filter housing had been disinfected on a regular basis, but there was no information recorded about the concentration or contact time. A similar violation was written on the previous inspection.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 08
Site: Potable Water-International Shore Connection
Violation: The reduced pressure assembly backflow preventer was not permanently installed on the fire line. Staff stated in the event of a fire the device would be installed on the line before connecting to the shore water supply. This was written on the previous inspection.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (20) international fire and fire sprinkler water connections (install a reduced pressure assembly).
Item No.: 10
Site: Recreational Water Facilities-High and Low Level Alarms
Violation: No high and low level alarms for pH and halogen were installed for the two hot tubs. This was written on the previous two inspections.
Recommendation: Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 44
Site: Recreational Water Facilities-
Violation: The two hot tubs were not being maintained in accordance with the 2011 VSP Operations Manual, including record-keeping, high and low level alarms, shock halogenation, hair and lint strainer and housing disinfection, antientrapment protection, electronic data logger security, and safety signs. Most of these items were written on the previous inspection or previous two inspections.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The OPRP included the following statement regarding the disinfectants: '...using Oxivir wipes, or a chlorine solution at a concentration of 1000 ppm. Contact time will be no less than 1 minute.' However, Oxivir makes two products with different contact times. Oxivir TB has a contact time of one minute and Oxivir Five 16 has a contact time of 5 minutes. The plan did not specify which form of Oxivir was to be used. Oxivir TB wipes were on board the ship. Also, 1000 ppm chlorine requires a minimum contact time of 5 minutes.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
Item No.: 41
Site: Housekeeping-Public Toilet Room Signs
Violation: There was no sign advising users to wash their hands and no sign advising users to use a paper towel to open the door.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free. Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands.
Item No.: *
Site: *General Comments-Food Service
Violation: Substantial improvement had been made in the food preparation and storage facilities on the Safari Endeavor since the last USPHS inspection. The enhancement of the lighting and bringing the nonfood contact surfaces into compliance with the VSP Operations Manual is to be commended.
Recommendation:
Item No.: 19
Site: Galley-Walk-In Cooler
Violation: A plastic bin of lettuce on the back shelf was not covered.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected.
Item No.: 16
Site: Bar-Explorer Lounge
Violation: An opened half-gallon of cream and an opened quart of almond milk was found in the back undercounter refrigerator both at 46°F. These products were immediately discarded.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 20
Site: Bar-Explorer Lounge
Violation: The back undercounter refrigerator had an ambient temperature of 45°F as shown on the thermometer inside the unit.
Recommendation: Ensure equipment for holding cold d hot food is sufficieint to maintain potentially hazardous food temperatures.
Item No.: 19
Site: Dining Room-Wine Service Area
Violation: Two full bins of coffee were found stored directly on the deck from an earlier provisioning.
Recommendation: Protect food from contamination by storing the food: (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 26
Site: Bar-Explorer Lounge
Violation: Mold was found in the plastic storage holster for the dispensing nozzle of the carbonated beverage multiflow system.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 22
Site: Bar-Explorer Lounge
Violation: A sanitizing solution was heavily soiled in the wiping cloth bucket.
Recommendation: Ensure the wash, rinse, and sanitize solutions are maintained clean.
Item No.: 33
Site: Bar-Explorer Lounge
Violation: The deck in the working area of the bar was in very bad repair and was pitted and difficult to clean. A large amount of old food and beverage soil was found on the deck. The attached beverage lines for the carbonated beverage and bulk wine systems are installed in a way that impeded cleaning the facility and the lines were soiled. A particularly difficult to clean corner was found between the handsink and adjacent dry storage cabinet.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure surfaces subject to routine splashes, spillage, or other soiling during normal use have easily cleanable features. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 21
Site: Bar-Explorer Lounge
Violation: The poor arrangement of the counters and cabinets in the bar's working area contributed to the difficult to clean areas.
Recommendation: Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead.
Item No.: 33
Site: Food Service General-Dining Room / Lounge
Violation: The counter/deck juncture in the dining room and lounge, that had been cited on previous inspections, had not been coved. The deckhead tiles mentioned on the previous inspection in these areas was still difficult to clean.
Recommendation: Cove all cabinet/deck junctures, including buffets, bars, waiter stations, dining room work counters. Ensure deckheads have smooth, hard finishes and are are easily cleanable.