Cruise Ship: Le Soleal Cruise Line: Compagnie Du Ponant SA Inspection Date: 07/28/2016 Inspection Score: 87
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 36
Site: Galley-Le Rodrigues Warewash
Violation: The light intensity at the two basin handwash sink at the entrance to the warewashing area was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 26
Site: Preparation Room-Buffet/Butcher Preparation Room
Violation: Two previously cleaned cutting boards stored on the vegetable preparation counter were slightly soiled with food residue. The countertop stainless steel storage rack for the cutting boards was also slightly soiled with food debris. The cutting boards and storage rack were immediately sent to be rewashed.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 20
Site: Preparation Room-Buffet/Butcher Preparation Room
Violation: The mechanical potato peeler had approximately 10 slotted fasteners in the food contact area of the machine.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 17
Site: Galley-Walk-In Refrigerator
Violation: A small plastic container of cut Chinese cabbage was stored in walk-in refrigerator at a temperature of 45°F (7°C) at 11:00 am. According to staff, the cabbage was cut and washed earlier in the morning (around 8:30 am) and placed in the walk-in refrigerator. The cooling processed was not monitored. Staff was given the choice to cool the Chinese cabbage to 41°F (5°C) or below before 12:30 pm, but chose to discard the product instead as a precaution.
Recommendation: Ensure cooling is accomplished using one or more of the following methods based on the type of food being cooled: (1) Placing the food in shallow pans; (2) Separating the food into smaller or thinner portions; (3) Using blast coolers, freezers, or other rapid cooling equipment; (4) Stirring the food in a container placed in an ice water bath; (5) Using containers that facilitate heat transfer; (6) Adding ice as an ingredient; or (7) Other effective methods. When placed in cooling or cold-holding equipment, ensure food containers in which food is being cooled are arranged in the equipment to provide maximum heat transfer through the container walls and loosely covered?or uncovered if protected from overhead contamination?during the cooling period to facilitate heat transfer from the surface of the food.
Item No.: 13
Site: Galley-Cut-Leafy Greens
Violation: Staff in-charge of handling and preparing cabbage and lettuce were not aware that the products were potentially hazardous once cut.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control pints in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual. Ensure the supervisor or person in charge of food operations on the vessel monitors that: (1) Food operations are not conducted in a room used as living or sleeping quarters; (2) Persons unnecessary to the food operation are not allowed in the food preparation, food storage, or warewashing areas. (3) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with the guidelines in this manual; (4) Food employees are effectively cleaning their hands; (5) Employees are observing foods as they are received to determine that they are from approved sources, delivered at the required temperatures, protected from contamination, unadulterated, and accurately presented; (6) Employees are properly cooking potentially hazardous food, being particularly careful in cooking foods known to cause severe foodborne illness and death, such as eggs and comminuted meats; (7) Employees are using proper methods to rapidly cool potentially hazardous foods that are not held hot or are not for consumption within 4 hours; (8) Consumers who order raw or partially cooked ready-to-eat foods of animal origin are informed that the food is not cooked sufficiently to ensure its safety; (9) Employees are properly sanitizing cleaned multiuse equipment and utensils before they are reused; (10) Consumers are notified that clean tableware is to be used when they return to self-service areas such as salad bars and buffets; (11) Employees are preventing cross-contamination of ready-to-eat food with bare hands by properly using suitable utensils such as deli tissue, spatulas, tongs, single-use gloves, or dispensing equipment; (12) Employees are properly trained in food safety, including food allergy awareness, as it relates to their assigned duties; (13) Food employees are informed of their responsibility to report to the supervisor or person in charge information about their health and activities as they relate to diseases that are transmissible through food.
Item No.: 22
Site: Galley-Warewash
Violation: The final rinse water pressure gauge on the rack-type dishwashing machine read 35 psi during active use. The data plate stated the final rinse pressure must be 20 psi +/- 5 psi.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 30
Site: Galley-Toilet Room
Violation: The employee toilet room was not self-closing.
Recommendation: Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
Item No.: 24
Site: Galley-Pot Wash
Violation: The chlorine concentration in the third compartment of the three compartment sink was less than 50 ppm when measured by the inspector and staff. The three-compartment sink was in active use during the inspection.
Recommendation: Ensure sanitizing solutions are used with the following concentrations: (1) A chlorine solution with a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 22
Site: Galley-Pot Wash
Violation: The mechanical pot wash machine had been out-of-order for three weeks. Documentation provided to the inspector showed the spare parts needed to repair the machine had been ordered.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 16
Site: Food Service General-Consumer Advisories
Violation: A main dining room menu from 27 July had a consumer advisory on the bottom but the grilled beef ribeye, hamburger, and cheeseburger under the 'available everyday' section did not have asterisks. According to staff, these items could be cooked-to-order per the passenger's request. The lunch and dinner room service menu in the guest cabins had a consumer advisory on the bottom but the smoked salmon, grilled ribeye steak, hamburger, and cheeseburger did not have asterisks. According to staff, the smoked salmon was served raw and the other items could be cooked-to-order per the passenger's request.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 37
Site: Buffet-Crew Mess
Violation: An excessive amount of steam was being released from the bain marie, which caused condensation to begin accumulating on the back bulkhead and deckhead above the hot buffet line. No condensation was observed dripping into food.
Recommendation: Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 33
Site: Bar-Main Lounge
Violation: A self-service coffee station for passengers was set-up at the entrance to the lounge and included several coffee pots and milk containers. This coffee station was set-up over a carpeted area. Staff stated this coffee station was regularly set-up in this location during voyages.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 36
Site: Bar-Main Lounge
Violation: The light intensity at the self-service coffee station for passengers was less than 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 08
Site: Potable Water-Houskeeping Deck Pantries
Violation: The potable water lines to the handwash station in each deck housekeeping locker were not striped blue or blue/green/blue to indicate potable water.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations.
Item No.: 08
Site: Potable Water-Cabin 604
Violation: No backflow prevention device was installed on the potable water supply line to the hand shower in the whirlpool tub. This hand shower feature was on a flexible hose that could touch and be left in the bottom of the tub.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities.
Item No.: 01
Site: Medical-24-hour Acute Gastroenteritis (AGE) Report
Violation: The 24-hour report for the Petersburg, AK port on the 16-28 voyage stated the incorrect dates for embarkation and disembarkation.
Recommendation: Ensure the AGE report contains the following: (1) name of the vessel; (2) port of embarkation; (3) date of embarkation; (4) port of disembarkation; (5) date of disembarkation; (6) total numbers of reportable cases of AGE among passengers, including those who have disembarked because of illness?even if the number is 0 (zero reporting); (7) total numbers of reportable cases of AGE among crew members, including those who have disembarked because of illness?even if the number is 0 (zero reporting); and (8) total number of passengers and crew members on the cruise.
Item No.: 02
Site: Medical-AGE Specimen Colleciton
Violation: The ship did not have any bacterial specimen collection containers. These were on order.
Recommendation: Ensure the medical staff maintains a supply of at least 10 clinical specimen collection containers for both viral and bacterial agents (10 for each).
Item No.: 02
Site: Medical-Fact Sheet
Violation: Medical did not have a written handwashing and hygiene fact sheet for AGE symptomatic crew, asymptomatic cabin mates, of AGE symptomatic passengers. This was corrected.
Recommendation: Advise symptomatic passengers of hygiene and handwashing facts and provide written handwashing and hygiene fact sheets. When any crew member (food or nonfood employee) meets the case definition for AGE, take the following actions: (2) provide facts and a written fact sheet about hygiene and handwashing.
Item No.: 06
Site: Medical-Incubator for microbiological water testing
Violation: The ship-made directions stated the temperature of the incubator should be 36 +/- 2°C, and the manufacturer's instructions stated the temperature should be 35 +/- 0.5°C. This was corrected.
Recommendation: If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers? specifications.
Item No.: 40
Site: Integrated Pest Management-Logs
Violation: No logs were available to verify pest inspections were conducted for incoming shipments/provisions; staff stated this was performed, but not recorded. Additionally, the ship conducted night inspections once per month, but it was unclear from the logs which inspections were conducted at night.
Recommendation: Routinely inspect incoming shipments of food and all other supplies for evidence of insects, rodents, and other pests. Maintain a record of these inspections onboard the vessel and make the record available for review during inspections. Ensure the IPM Plan sets a schedule for periodic active monitoring inspections, including some at night or during periods of no or minimal activity.
Item No.: 08
Site: Potable Water-Deck 1, Frame 117
Violation: The water line was striped blue prior to the chlorine injection point, and not striped blue gray blue.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 08
Site: Potable Water-Deck 1, Frame 117
Violation: The distance between the chlorine injection point and sample collection point for the analyzer was less than 3 meters (10 feet).
Recommendation: Obtain water samples for halogen and pH testing from a sample cock and/or a halogen analyzer probe located on the bunker or production water line at least 3 meters (10 feet) after the halogen injection point and before the storage tank.
Item No.: *
Site: Potable Water-Production/Bunker Records
Violation: The bunker and production records showed the pH to be between 3 and 4. Staff explained they were intentionally dividing the pH by two, so the pH and chlorine probes did not touch and the ink did not run together.
Recommendation: Ensure the pH value during water production is being accurately recorded on the chart records.
Item No.: 08
Site: Potable Water-Tank Maintenance Records
Violation: The ship did not have written documentation of approval from the certification organization from tank maintenance that was conducted March to May 2015.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer).
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool
Violation: The rope attached to the flotation device was not at least 2/3 the distance of the maximum widths of the pool.
Recommendation: Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
Item No.: 09
Site: Recreational Water Facilities-Swimming Pool
Violation: The pool was open during the inspection, and the free halogen residual levels were less than 1.0 ppm. The inspector measured 0.47 ppm and the analyzer in the machinery room stated 0.52 ppm. The low level halogen alarm was set for 0.25 ppm.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm).
Item No.: 10
Site: Recreational Water Facilities-Pool Test Kit
Violation: The ship did not have secondary standards for the pool testing kit. The inspector measure 0.47 ppm in the swimming pool, and the ship staff measured 1.19 ppm.
Recommendation: Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool Records
Violation: From 24 May to 27 July 2016 the free halogen residual values were lower than the minimum 1.0 ppm for 4-10 hours on at least eight days.
Recommendation: Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm).
Item No.: 05
Site: Potable Water-Far Point
Violation: The far point analyzer stated 1.83 ppm for the free halogen residual value, and was inaccurate. The inspector measured the free halogen residual to be 5.28 and 4.96 ppm; the ship measured the free halogen residual to be 4.72 and 4.6 ppm.
Recommendation: Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 44
Site: Recreational Water Facilities-Swimming Pool
Violation: The swimming pool records revealed the swimming pool had free halogen residuals below 1.0 ppm on many different days for many hours. During the inspection, it was discovered the low halogen alarm was set for 0.25 ppm, and the test kit used to measure the pool chemistry was out of calibration, and no secondary standards were available.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP?during inspections and on request ? knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 04
Site: Potable Water-Far Point
Violation: The inspector measured the free halogen residual values to be 4.96 and 5.28 ppm. The maximum level for the halogen residual value in the potable water distribution system is 5.0 ppm.
Recommendation: Provide continuous halogenation of the potable water system using halogenation injection equipment and maintain a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 08
Site: Potable Water-Testable Devices
Violation: The logs for reduced pressure (RP) backflow preventers for the two international fire shore connections (on Deck 4 mooring deck), the mineralizer backwash line (on deck 1), and the two high saline discharge on reverse osmosis did not document test results for pressure differentials. Visual inspections were documented for these RPs.
Recommendation: Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device. Retain the inspection and test results for backflow prevention devices for at least 12 months and ensure they are available for review during inspections.
Item No.: 44
Site: Potable Water-Far Point
Violation: No secondary standards were available for the test kit used to measure the free halogen residual level at the far point, and the far point halogen analyzer was significantly out of calibration.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 10
Site: Recreational Water Facilities-Swimming Pool Machinery Room
Violation: The low halogen alarm was set for 0.25 ppm.
Recommendation: Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF. It is recommended to set the low free halogen alarm above 1.0 ppm (the minimum halogen value requirement in swimming pools), around 1.5 ppm.
Item No.: 06
Site: Potable Water-Test Kit
Violation: No secondary standards were available for the test kit used to measure the free halogen residual levels and pH for the potable water system.
Recommendation: Where available, maintain appropriate secondary standards onboard for electronic test kits to verify test kit operation.
Item No.: 22
Site: Galley-Crew Mess Warewash
Violation: The hood-type dishwashing machine had been out-of-order for three weeks according to staff. Documentation provided to the inspector showed the spare parts needed to repair the machine had been ordered. An undercounter dishwashing machine was operational in the area, and staff stated any overflow equipment was sent to the dishwashing machine in the main galley.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.