Item No.:
01
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
On 18 September, the ship arrived in New York. This was the first U.S. port in the itinerary after several international ports. The medical logs indicated 112 passenger reportable AGE cases out of 2033 total passengers and 6 crew reportable AGE cases out of 860 total crew members. The ship did not submit a 24-hour report 24-36 hours prior to arrival to New York.
|
|
Recommendation:
Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours?but not more than 36 hours?before the vessel?s expected arrival at the U.S. port.
|
|
|
Item No.:
02
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Log
|
|
Violation:
The previous inspection of January 2015 found that 1 crew member with 2 diarrheas, abnormal for the individual, was deemed as a nonreportable AGE case by the medical staff. The current inspection found 24 passengers reported having at least 1 diarrhea, which was above normal for them, and were deemed nonreportable AGE cases while having no underlying illness or an underlying illness that could trigger the AGE symptoms.
|
|
Recommendation:
Ensure a reportable case of AGE is a case reported to the master of the vessel, the medical staff, or other designated staff by a passenger or a crew member and meets the case definition based on the following symptoms: (1) Diarrhea (three or more episodes of loose stools in a 24 hour period or what is above normal for the individual. See section 4.1.2.1.3, illness symptoms); or (2) vomiting and one additional symptom including one or more episodes of loose stools in a 24-hour period, or abdominal cramps, or headache, or muscle aches, or fever (temperature of greater than or equal to 38°C [100.4°F]).
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Disinfection Records
|
|
Violation:
Records documented a pipe replacement on decks 5 and 6 done on 16 September. The pipes were disinfected appropriately with a chlorine solution of 50 ppm for 4 hours, but no information was available about flushing and the free halogen test result prior to putting the system back in service.
|
|
Recommendation:
Document the free halogen residual level. Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Sedimentation Test Results
|
|
Violation:
Sedimentation tests were performed monthly for whirlpools, as required, but the results of the inspections were not consistently documented.
|
|
Recommendation:
Examine granular filter media for channels, mounds, or holes. Inspect a core sample of the filter media for excessive organic material accumulation using a recommended sedimentation method. Record the results of both the filter inspection and sedimentation test.
|
|
|
Item No.:
11
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
A chef with AGE symptoms experienced his last symptom of 2 diarrheas on 29 August at 1045 and was deemed fit to return to work on 30 August at 0845. The chef was isolated 22 hours after his last symptoms, and not isolated for a minimum of 48 hours as required for food workers.
|
|
Recommendation:
When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours.
|
|
|
Item No.:
11
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Reporting
|
|
Violation:
The previous inspection of January 2015 found 2 crew members, 1 food worker and 1 nonfood worker, which reported to the medical center 6-7 hours after AGE illness onset. The current inspection revealed that 2 crew members experienced AGE symptoms and reported to the medical center after several hours of AGE illness onset. Specifically, (1) a chef had an illness onset on 26 August at 0800 but reported to the medical center at 1645 that day; and (2) a guest entertainer had an illness onset on 31 August at 1600 but reported to the medical center at 2045 that day. Records showed that both crew members did not work between the times of illness onset and reporting to the medical center. No documentation was available to show these crew members received disciplinary action.
|
|
Recommendation:
When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Belvedere
|
|
Violation:
The hot carving stations on the service lines were not listed on the time control plan as time control units.
|
|
Recommendation:
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such)
|
|
|
Item No.:
16
|
|
Site:
Galley-Deck 2 Production
|
|
Violation:
A cooling log listed boiled chicken with an initial time of 0240 and temperature of 75·C on 22 September, and no cooling temperatures were recorded. The boiled chicken was in one of the undercounter refrigerators and discarded around 1030.
|
|
Recommendation:
Ensure cooked potentially hazardous food is cooled from 57°C (135°F) to 21°C (70°F) within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within 4 hours.
|
|
|
Item No.:
16
|
|
Site:
Galley-Neptune Grill
|
|
Violation:
Five containers of potentially hazardous foods, stored in an upright refrigerator on time control, did not have 4-hour discard labels attached to the containers; the service period was over 4 hours. Also, these containers had discard labels with date of discard, which should only be used when food is on temperature control.
|
|
Recommendation:
If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours.
|
|
|
Item No.:
19
|
|
Site:
Provisions-Deck A- Cambusa Square
|
|
Violation:
Numerous kegs were stored in this area that was not constructed to dry store standards. The deckhead was open to soiled wiring and pipes . This was noted on the last inspection. Staff covered the kegs with plastic pallet covers to protect them from potential contamination.
|
|
Recommendation:
Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
21
|
|
Site:
Galley-Undercounter Ovens
|
|
Violation:
The technical area of the left undercounter oven was open to void space and exposed surfaces that were not easily cleanable.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-Ice Machines
|
|
Violation:
The outer deflector shields in the ice machines were covered in foam, which is an absorbable non-cleanable material.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 2 Pot Wash
|
|
Violation:
The sanitizing rinse temperature gauge of the 3-compartment sink was inaccurate by at least 10°F.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 3 Potwash
|
|
Violation:
The sanitizing rinse temperature gauge of the 3-compartment sink was inaccurate by at least 20°F.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Deck 2 Pot Wash
|
|
Violation:
A new hood-type potwasher had been installed recently, but was not in operation during the inspection. Contractors were scheduled to come onboard on 5 October to completely install potwasher. The soiled pots and pans were being cleaned on deck 3.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The leftmost nozzle on the upper final rinse arm was blocked, and no spray was observed coming from this nozzle when the rack-type dishwasher was in active use.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Belvedere Dishwash
|
|
Violation:
The rightmost nozzle on the upper final rinse arm of conveyor dishwasher was partially clogged.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
26
|
|
Site:
Preparation Room-
|
|
Violation:
Food soil, particularly starch, was noted around the gaskets on the openings of the potato peelers.
|
|
Recommendation:
Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Undercounter Ovens
|
|
Violation:
The area underneath the right undercounter door was heavily soiled with debris. The technical area of the left undercounter oven was exposed and soiled.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
29
|
|
Site:
Buffet-Forward Service Line
|
|
Violation:
A handwashing station for the food workers was not available on this service line, and the closest handwashing station was over 8 meters by the crew mess entrance.
|
|
Recommendation:
Ensure a handwashing facility is within 8 meters (26 feet) of all parts of the area and is not located in an adjacent area that requires passage through a closed door where the user makes hand contact with the door. Ensure handwash sinks are at least 750 millimeters (30 inches) above the deck so that employees do not have to reach excessively to wash their hands.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Deck A- Cambusa Square
|
|
Violation:
Numerous kegs were stored in this area that was not constructed to dry store standards. The deckhead was open to soiled wiring and pipes . This was noted on the last inspection. Staff covered the kegs with plastic pallet covers to protect them from potential contamination.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 2- Hot Section
|
|
Violation:
Water was dripping from a deckhead light onto the deck.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Preparation Room-
|
|
Violation:
Water was dripping from the pulper and accumulating on the deck.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
34
|
|
Site:
Medical-Pantry
|
|
Violation:
The handwashing sink did not drain appropriately. Water filled up the basin, making it difficult not to touch the soiled water during handwashing.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Lighting
|
|
Violation:
The light intensity was less than 110 lux behind and around many different types of equipment, to include ice machines and combination ovens, in all galleys. Many of these lighting issues were noted on the last three inspections in the Deck 2/3 main galleys and Deck 9 Belvedere galley. The ship staff stated this would be rectified during the October 2017 dry dock.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 2
|
|
Violation:
One live fruit fly was observed in the hot section by the flat top grill. One live fruit fly was observed by the ice machine.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Preparation Room-
|
|
Violation:
One live fruit fly was observed in one of the potato peelers.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 3
|
|
Violation:
One live fruit fly was noted by the combination ovens. One live fruit fly was noted by the hot line.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Dining Room-Sindu
|
|
Violation:
One large house fly was observed flying in this area.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
39
|
|
Site:
Bar-Crow's Nest
|
|
Violation:
One live fruit fly was noted in this area.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
44
|
|
Site:
Medical-Acute Gastroenteritis (AGE) Logs
|
|
Violation:
The review of the previous AGE surveillance logs for the previous voyages found a number of instances where the definition of an AGE reportable case was not applied appropriately. Staff stated the electronic database decided when a case was reportable or not, depending on 3 or more diarrheas or vomit plus one additional symptom. Staff added that they could override the reportable case decision making of the electronic database if necessary, but this was not done at least 24 times on the voyage that exceeded 5% of AGE passenger reportable cases with disembarkation on 18 September. In addition, the records used by the staff had a box to check if symptoms were above normal for the individual and there were several instances when the box was not checked. Although everyone on the AGE surveillance log was isolated, a chef was also isolated for only 22 hours after last AGE symptoms during the recent outbreak. Also, there was no 24-hour report submitted to VSP prior to arrival to New York on 18 September because the ship sent a special report 15 days prior to arrival and did not know about the need to send another report 24-36 hours prior arrival to the U.S.
|
|
Recommendation:
Ensure the supervisor or person in charge of medical operations related to AGE on the vessel demonstrates to VSP?during inspections and on request?knowledge of medical operations related to AGE, is able to demonstrate this knowledge by compliance with Section 4 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 4 of the VSP 2011 Operations Manual as it relates to their assigned duties.
|
|