Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Europa 2 Cruise Line: Hapag-Lloyd Cruises Inspection Date: 09/26/2016 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 38
Site: Children Area-Pantry
Violation: The undercounter warewasher was out of service. The engineering staff stated that the machine was not needed for the operation of the pantry and would remove it.
Recommendation: Ensure only articles necessary for the food service operation are stored in food preparation, food storage, and warewashing areas.
Item No.: 02
Site: Medical-Food/Beverage Questionnaire
Violation: The self-administered questionnaires did not contain all data elements that appear in the questionnaire found in Annex 13.2.2. Specifically, only the food and shipboard activities history was used. Staff was unaware of the first page of this questionnaire as found on page 171 of the 2011 VSP Operations Manual.
Recommendation: Distribute questionnaires detailing activities and meal locations for the 72 hours before illness onset to all passengers and crew members who are AGE CASES. Ensure that the self-administered questionnaires contain all of the data elements that appear in the questionnaire found in Annex 13.2.2. Ensure that completed questionnaires are maintained with the AGE surveillance log.
Item No.: 06
Site: Potable Water-Potable Water Testing
Violation: The color comparator for analyzing results of the potable water testing method (Colisure-18) for microbiological monitoring expired on 14 November 2013. This comparator was used to decide if samples were positive or negative for total coliforms and E. Coli. Records indicated all results were negative for the bunkered water and random samples collected.
Recommendation: If water samples are collected and analyzed by the vessel for the presence of E. coli, analyze the samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Ensure test kits, incubators, and associated equipment are operated and maintained in accordance with the manufacturers' specifications. Analyze samples using a method accepted in Standard Methods for the Examination of Water and Wastewater. Operate and maintain test kits, incubators, and associated equipment in accordance with the manufacturers' specifications.
Item No.: 08
Site: Potable Water-Tank Maintenance
Violation: All potable water tanks were appropriately cleaned and disinfected in April 2015. Records indicated a halogen residual of less than 5 ppm before putting the tanks back in service but the actual residual was not documented.
Recommendation: Document the free halogen residual level.
Item No.: 40
Site: Integrated Pest Management-Active Monitoring
Violation: The IPM active monitoring records indicated inspections by deck and 9 am and 10 pm times but were not specific to the places inspected and the times when the inspections occurred.
Recommendation: Ensure the IPM Plan includes provisions for logs for active monitoring of pest sightings in operational areas of the vessel. Ensure the IPM plan includes provisions for training of crew members in charge of log completion. Record the time of the active monitoring inspections in the log.
Item No.: 10
Site: Recreational Water Facilities-
Violation: Staff had no means to inspect combined chlorine levels and total alkalinity. Chlorine was used in all RWFs.
Recommendation: Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
Item No.: 44
Site: Potable Water-Potable Water Testing
Violation: The color comparator for analyzing results of the potable water testing method (Colisure-18) for microbiological monitoring expired almost three years ago on 14 November 2013. This comparator was used to decide if samples were positive or negative for total coliforms and E. Coli. Records indicated all results were negative for the bunkered water and random samples collected. Although the expiration year was taken off the box where the comparator was stored, the complete expiration date was clearly printed on the bottle's cap label.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP-during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 44
Site: Recreational Water Facilities-
Violation: Staff had no means to inspect combined chlorine levels and total alkalinity. Chlorine was used in all RWFs. Staff could only measure free chlorine and pH levels.
Recommendation: Ensure the supervisor or person in charge of recreational water operations on the vessel demonstrates to VSP-during inspections and on request - knowledge of recreational water operations, is able to demonstrate this knowledge by compliance with Section 6 of the VSP 2011 Operations Manual or by responding correctly to the inspector's questions as they relate to the specific operation, and properly trains employees to comply with Section 6 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 42
Site: Children Area-
Violation: The maximum water temperature for the handwashing stations in the aft toilet room and the play room was 135-137°F. This same violation was found during the inspection conducted in March 2015.
Recommendation: Ensure the maximum water temperature for a handwashing station does not exceed 43°C (110°F).
Item No.: 22
Site: Children Area-Pantry
Violation: The undercounter warewasher was out of service. The children area staff stated that they did not remember when the machine was operational.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 10
Site: Housekeeping-Private Whirlpool Disinfection
Violation: The CT value of the disinfectant used during the weekly cleaning and disinfection of whirlpools inside cabins was unknown. The chemical WhirlWannen DES Q15 was an ammonium chloride compounds chemical and staff was using 75 mL for 20 minutes. The concentration in mg/L was unknown and there was no means to test if a certain concentration was achieved.
Recommendation: Clean and disinfect private whirlpool spas located in individual passenger cabins, including associated recirculation systems, between occupancies or weekly, whichever is more frequent. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant at 10 ppm for 60 minutes, or an equivalent CT value. Ensure to have a test kit or other device that accurately measures the concentration in milligrams per liter (parts per million) of sanitizing solutions.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: Procedures for informing passengers and crew members of the outbreak during a current voyage were not found.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak.
Item No.: 20
Site: Food Service General-Equipment
Violation: Several pieces of equipment had slotted fasteners on food-contact or food splash surfaces. This included: the ice machines on the sensor thickness probe in the Yacht Club pantry and main galley, the two juice machines at the crew mess beverage station, the espresso machine in Sansibar, and the deli slicer on the Yacht Club service line.
Recommendation: Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 16
Site: Dining Room-Sansibar
Violation: The menu for the Sansibar restaurant and the room service did not have a public health advisory to indicate that the cold smoked fish, roast beef, and fried eggs were cooked to order or served undercooked. This was immediately corrected.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Ensure that disclosure is on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 19
Site: Dining Room-Weltmeere
Violation: The buffet station did not have side sneeze shields on the aft self-service line. The distance between exposed food and where consumers could stand was less than 1 meter (40 inches). This was corrected.
Recommendation: Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means. Install side protection for sneeze guards if the distance between exposed food and where consumers are expected to stand is less than 1 meter (40 inches).
Item No.: 16
Site: Galley-Tarragon Pantry
Violation: Many items of potentially hazardous foods, including cut tomatoes, quiches, and soups, stored in upright refrigerator 4.4.1 and undercounter drawers 4.4.2 had 8-day discard labels.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 17
Site: Galley-Tarragon Pantry
Violation: No cooling log was available for the onion soup cooked on 24 September stored in upright refrigerator 4.4.1.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 16
Site: Galley-
Violation: A pan of potato salad had a discard date of 29 September, but the first ingredient (potato) was cooked on the 22 September. This mistake lead to an 8-day discard date.
Recommendation: Ensure refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food must be consumed (7 calendar days or fewer from the day the food is prepared). The day of preparation is counted as day 1. (2) Prepared and packaged by a food-processing plant and held on the vessel after opening for more than 24 hours must be clearly marked at the time the original container is opened to indicate the date by which the food must be consumed (7 calendar days or fewer after the original container is opened). The day of opening is counted as day 1.
Item No.: 28
Site: Galley-Potwash
Violation: A soiled mobile trolley of pots and pans was stored adjacent to a clean rack of pots and pans. This was immediately corrected.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 17
Site: Galley-
Violation: A container of cut cabbage in the upright refrigerator did not have a cooling log. Staff indicated they did not know this item needed to be cooled.
Recommendation: Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process. Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
Item No.: 18
Site: Preparation Room-Deck 3 Fish Walk-in Refrigerator
Violation: Sashimi was stored above a tray of cooked ready-to-eat lobsters.
Recommendation: Protect food from cross-contamination or other sources of contamination by the following methods: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food so that products do not physically touch and so that one product does not drip into another.
Item No.: 20
Site: Preparation Room-Deck 3 Bakery/Pastry Dough Sheeter
Violation: The cloth dough sheeter belt was not easy to clean, was torn, and in disrepair. Staff showed a purchase request for a synthetic dough sheeter belt to be delivered by 29 September.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 26
Site: Preparation Room-Deck 3 Bakery/Pastry Dough Sheeter
Violation: The previously cleaned and not in use dough sheeter belt was soiled with food debris.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 19
Site: Preparation Room-Deck 3 Bakery/Pastry Walk-in Freezer
Violation: Frozen condensate was noted on top of a plastic film covering a dessert pan.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 15
Site: Provisions-Shucked Shellfish
Violation: The ship served raw oysters on the half shell and dis not maintain the shellfish tags/labels for 90 calendar days from the date the box was emptied. Ship staff was not aware of this requirement.
Recommendation: Ensure shellstock shellfish tags: (1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Are maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record-keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served and the date when the last shellstock from the container is served is recorded on the tag or label.
Item No.: 16
Site: Galley-Sakura
Violation: The Asia Salmon Shot, which contains undercooked salmon, did not have a public health advisory on the menu.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Ensure that disclosure is on a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 16
Site: Galley-Sakura
Violation: Staff reported the rice cooker was used as a time control unit but it was not listed on the time control plan.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
Item No.: 22
Site: Galley-Conveyor Rack-type Dishwasher
Violation: The final rinse temperature at the utensil surface was inconsistently reaching the minimum 160°F. The 180°F thermolabel attached to the final rinse supply pipe was activated, but the final rinse temperatures at the utensil surface mainly ranged from 145° to 153°F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 13
Site: Food Service General-
Violation: Several food safety issues were identified on the inspection, which appeared to be due to a lack of supervisor knowledge/training. (1) Many potentially hazardous food items in temperature control had 8-day discard labels in the Tarragon pantry. (2) Staff was not aware that cut cabbage was a potentially hazardous food and should be cooled, as well as recorded on the cooling log. (3) Staff did not know that the shucked shellfish tags should be maintained and kept for 90 days from the date the container was emptied.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
*Inspections scores of 85 or lower are NOT satisfactory