Item No.: 16
Site: Buffet-Lido Café Omelet Stations
Violation: A consumer advisory was at the stations for eggs cooked to order. However, cold smoked salmon was an optional ingredient for the omelets and the advisory did not include the salmon. This was corrected.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 27
Site: Galley-Starboard Hot Section
Violation: The oven mitts on top of the combination oven were heavily soiled with food residues from the day prior.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Trident Grill Dishwash
Violation: The rack-type warewasher was out of service since the morning. The machine was being repaired during the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 36
Site: Food Service General-Lighting
Violation: In the pantries and the galleys, the light intensity behind and around many pieces of counter-mounted and deck-mounted equipment was less than 110 lux. In addition, the lighting at many handwashing stations in galleys and pantries was less than 220 lux. Also, the lighting was not able to be raised to 220 lux for cleaning at the ice cream bar, Trident Grill Bar, and the 5 Prego Restaurant waiter stations. This was also noted in the previous inspections of November 2015 and June 2016. The ship plans to make corrections during the 2017 dry-dock but there is still no lighting plan identifying areas of poor lighting to make corrections during dry-dock.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas. Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment. Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 20
Site: Galley-Trident Grill
Violation: The self-service water/ice machine had several slotted fasteners in the food splash zone that were corroded.
Recommendation: Materials used in the construction of multiuse utensils and food contact surfaces of equipment must be: (1) durable, corrosion resistant, and nonabsorbent; (2) sufficient in weight and thickness to withstand repeated warewashing; (3) finished to have a smooth, easily cleanable surface; and (4) resistant to pitting, chipping, crazing, scratching, scoring, distortion and decomposition. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 29
Site: Galley-Deck 9 Room Service Pantry
Violation: The crew employee restroom was locked while the pantry was in service.
Recommendation: Ensure toilet facilities intended for use by galley personnel are not locked when the galley is in service.
Item No.: 29
Site: Food Service General-Handwashing Temperature
Violation: The water temperature at several handwashing stations in pantries, preparation rooms, and galleys were above 120°F (127-134°F) even in the cold settings. The temperatures of some stations were adjusted and others were still to be corrected.
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. For handwash sinks with electronic sensors, and other types of handwash sinks where the user cannot make temperature adjustments, ensure the temperature provided to the user after the mixing valve does not exceed 49°C (120°F).
Item No.: 30
Site: Food Service General-Handwashing Stations
Violation: The paper towel dispensers at many handwashing stations in the food areas were heavily soiled with dust where the paper was dispensed. In addition, a number of handwashing stations were draining so slowly that the water level raised enough to touch the hands during handwashing and some were about to overflow the sinks.
Recommendation: Keep handwashing facilities clean and in good repair.
Item No.: 39
Site: Galley-Prego Restaurant Dishwash
Violation: Three flies were around the pulper system. Treatment started immediately after the finding.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 27
Site: Galley-Prego Restaurant
Violation: Dust was accumulated on the tubes and pipes behind the ice machine. Cleaning started immediately after the finding.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-Prego Restaurant
Violation: The previously cleaned food slicer had a heavy build-up of food residue under the slicer's backplate next to the exit path of the food from the slicer blade.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 34
Site: Galley-Prego Restaurant Potwash
Violation: There was stagnant water in the trough of the prewash station due to a clogged drain. This was corrected.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 26
Site: Galley-Prego Restaurant Potwash
Violation: A large pan was stored hanging soiled on the clean storage racks. It was taken to be rewashed.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 13
Site: Galley-Prego Restaurant Potwash
Violation: A technician knocked off two pans at different times from the clean storage racks to the deck and was about to put them back on the clean racks after being on the deck. The inspection team was the only reason the pans were not put back on the clean racks after being on the deck.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines. Ensure that the areas of knowledge include: (1) (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual. Ensure the supervisor or person in charge of food operations on the vessel monitors that: (3) Employees and other persons such as delivery and maintenance persons and pesticide applicators entering the food preparation, food storage, or warewashing areas comply with the guidelines in this manual.
Item No.: 33
Site: Dining Room-Prego Restaurant
Violation: The large up level waiter station had a carpeted deck. There was some food debris on the carpet.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 16
Site: Dining Room-Vintage Room
Violation: The menu had a consumer advisory but the cooked to order filet mignon had no asterisk linking the food to the advisory.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 16
Site: Pantry-Starlight - Captain Reception
Violation: The time control plan for canapes did not have the setup and discard times for the Captain Reception done from one to three times per voyage. This was corrected during the inspection.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 39
Site: Galley-Cold Section
Violation: One fly was in the area during food preparation.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 28
Site: Galley-Potwash
Violation: On the clean storage racks, there were over 30 pans stacked together dripping wet. These pans were separated to get air dried.
Recommendation: After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food.
Item No.: 19
Site: Galley-Potwash
Violation: The drain pipe of the potwash machine was inside the deck drain.
Recommendation: Ensure drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
Item No.: 12
Site: Galley-
Violation: A food employee was observed touching with bare hands fried eggs that he was taking to the staff mess during lunch.
Recommendation: Ensure food employees do not contact exposed, ready-to-eat food with their bare hands and that they use suitable utensils such as deli tissue, spatulas, tongs, single-use gloves, or dispensing equipment.
Item No.: 30
Site: Preparation Room-Fruit and Vegetable
Violation: The liquid soap at the handwash station was diluted with water.
Recommendation: Ensure that the handwashing soap is not diluted.
Item No.: 20
Site: Preparation Room-Fruit and Vegetable
Violation: The orange juice machine had four slotted fasteners in the food contact zone. Additionally, one of the parts with the fasteners was cracked and difficult to clean.
Recommendation: Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
Item No.: 19
Site: Galley-Potwash
Violation: The drain pipe of the potwash machine was inside the deck drain.
Recommendation: Ensure drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
Item No.: 19
Site: Buffet-The Bistro
Violation: During lunch service, a tray of salami and prosciutto had no serving utensil.
Recommendation: Provide food-dispensing utensils for each container displayed at a consumer self-service unit such as a buffet or salad bar.
Item No.: 11
Site: Medical-Acute Gastroenteritis (AGE) Reporting
Violation: An IT Consultant had an onset of AGE symptoms on 14 OCT at 1200 but did not report to the medical center until 15 OCT at 1335. According to his 72 hour questionnaire on the day of illness onset, he ate in the Lido Buffet at 1400 and Officer's Mess at 1800 and worked in the afternoon. He did not work on 15 OCT.
Recommendation: When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work.
Item No.: *
Site: Children Area-
Violation: The Child Activity Center was not in operation at the time of the inspection because no children were on board. Staff stated the center is used infrequently, typically around the holidays. There were no step stools in the toilet room designated for the child activity center designated for the sink and toilet. There was no sign advising child care staff to assist children with washing their hands after using the toilet. In addition, several plastic stackable block toys were found stacked together. Because the Child Activity Center had not been used for several cruises, it could not be determined if these blocks were separated during disinfection.
Recommendation: