|
|
|
Item No.:
06
|
|
Site:
Potable Water-Chart Recorder Range
|
|
Violation:
The far point halogen analyzer-chart recorder charts had a range of 0 to 50 mg/L (PPM)
|
|
Recommendation:
Ensure the halogen analyzer-chart recorder charts have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of (and limited to) 24 hours.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance
|
|
Violation:
The free halogen residual value was not being recorded before the potable water tanks were put back into service after maintenance was completed. Records only indicated that they were flushed or dechlorinated to a value less than 5 ppm.
|
|
Recommendation:
Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Bunkering Hoses
|
|
Violation:
The water bunkering hoses were laying directly on the pier while bunkering was taking place.
|
|
Recommendation:
Handle and store all hoses, fittings, water filters, buckets, equipment, and tools used for connection with the bunkering of potable water in a sanitary manner. Handle potable water hoses with care to prevent contamination from dragging on the ground, pier, or deck surfaces, or from dropping the hose into contaminated water.
|
|
|
Item No.:
08
|
|
Site:
Galley-Crew Dishwash
|
|
Violation:
The nozzle of the spray hose at the 3 compartment sink hung below the flood rim level and had no mechanical backflow prevention device. This was corrected during the inspection.
|
|
Recommendation:
Provide a comprehensive cross-connection control program. Protect all galley spray hoses against backflow with air gaps or mechanical backflow prevention devices.
|
|
|
Item No.:
09
|
|
Site:
Recreational Water Facilities-Swimming Pool Chlorine Residual
|
|
Violation:
The free chlorine residual at the open swimming pool was measured above 5 ppm when measured with the inspector's and crew's test kit. The free chlorine residual values taken at the pool with the inspector's test kit measured the following: greater than 6 ppm (twice) and 5.26 ppm. Samples were also taken from the analyzer sample tap in the pump room and recorded measurements that were too high to determine. High range measurements were conducted with the inspector's test kit from the analyzer sample tap in the pump room and recorded values between 8.02 and 8.10. The analyzer was showing a reading of 3.0 ppm. The pool was closed and the analyzer was re-calibrated.
|
|
Recommendation:
Maintain a free residual halogen in recirculated RWFs in the following ranges: (1) swimming pools, between 1.0 and 5.0 mg/L (ppm).
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Flow Meters
|
|
Violation:
The turnover rates for the RWFs were calculated based on theoretical pump rates and not actual values taken from flow meters installed on the return lines. Maximum bather load for each RWF was also calculated off theoretical pump rates and not actual flow values measured by flow meters. There were no flow meters installed on any of the RWFs and therefore, no way to monitor flow rates.
|
|
Recommendation:
Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (5) whirlpool spa: 0.5 hours. Turnover rates must be calculated based on actual flow rates and not from theoretical pump rates (Clarifications to the 2011 VSP Operations Manual). Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow. Monitor and adjust the RWF?s flow rates as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Antientrapment
|
|
Violation:
The single independent suction drain needed for water recirculation at both whirlpools had a cover that was ASME A112.19.8 compliant but did not meet the secondary antientrapment requirement of having either a safety vacuum release system or an automatic pump shut off system due to the single drain being blockable.
|
|
Recommendation:
For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-RWF Whirlpool Shock Halogenation
|
|
Violation:
The concentration of the free halogen residual was not documented at the start and completion of the shock chlorination for the whirlpools.
|
|
Recommendation:
Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing. Ensure a written or electronic record of the shock halogenation (concentration in ppm at the start and completion and time) is available for review during inspections.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Automated Free Halogen Residual and pH Testing
|
|
Violation:
There were no chart recorders or electronic data loggers with security features that record pH and free halogen at either of the two whirlpools.
|
|
Recommendation:
Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Test Kit
|
|
Violation:
There was no test kit that was able to test for total chlorine.
|
|
Recommendation:
Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates.
|
|
|
Item No.:
19
|
|
Site:
Buffet-Mess
|
|
Violation:
A rice warmer on the self-service line was not protected from contamination by a sneeze guard, nor did it have self-closing hinged lids or other effective means of protection.
|
|
Recommendation:
Protect food on display from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; self-closing hinged lids; or other effective means.
|
|
|
Item No.:
21
|
|
Site:
Galley-Coffee Station
|
|
Violation:
The electrical cords for the different beverage machines were laying directly on the counter making cleaning difficult.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Storage Room
|
|
Violation:
There was a trolley that was being used to transport serving trays that was badly scratched and scored in many areas preventing it from being cleaned properly.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The #2 rack-type dishwash machine was out of order.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The hood-type dishwash machine was out of order.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-Decks
|
|
Violation:
The deck tiles throughout food preparation and warewash areas were cracked and missing grouting. This was especially the case at coved areas around entrance ways and behind deck mounted equipment.
|
|
Recommendation:
Ensure deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Dry Storage
|
|
Violation:
The bulkhead behind the storage shelves had exposed insulation, making it difficult to clean.
|
|
Recommendation:
Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces.
|
|
|
Item No.:
33
|
|
Site:
Provisions-Wine Starage
|
|
Violation:
Insulation covering a refrigerant line at the deckhead was coming loose making cleaning difficult. The insulation appeared to be collecting dust.
|
|
Recommendation:
Ensure deckheads in food preparation areas are maintained in good repair. Ensure deckheads and attached equipment in storage areas are cleaned as often as necessary.
|
|
|
Item No.:
33
|
|
Site:
Galley-Bakery Room
|
|
Violation:
The deck behind the deck mounted bakery ovens was soiled with food and dirt residue.
|
|
Recommendation:
Ensure decks in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
|
|
|
Item No.:
36
|
|
Site:
Galley-Handwash Station
|
|
Violation:
The handwash station in the hot galley adjacent to the deck mounted refrigerators had less than the required 220 lux of light.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
36
|
|
Site:
Food Service General-Lighting
|
|
Violation:
Light intensity behind and around all deck mounted equipment did not reach 110 lux. This included behind deck mounted ice machines in housekeeping pantries, behind and around ice machines in galleys, and behind ovens in the bakery.
|
|
Recommendation:
|
|
|
Item No.:
38
|
|
Site:
Galley-Meat Preparation
|
|
Violation:
There was a deck mounted mixer in this area that has not been used for several years.
|
|
Recommendation:
Ensure only articles necessary for the food service operation are stored in food preparation areas.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-Outbreak Prevention and Response Plan (OPRP)
|
|
Violation:
The OPRP listed that a bleach water solution of 1000 ppm will be used to sanitize common public surfaces when 2% is reached but it did not list the contact time required.
|
|
Recommendation:
Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
|
|