Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Norwegian Dawn Cruise Line: Norwegian Cruise Lines Inspection Date: 06/01/2012 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 42
Site: Children Area-Splash Academy
Violation: There was no policy posted at the entrance of the center which indicated the requirement for written clearance from the medical staff before a child with symptoms of infectious illness can enter. This was corrected during the inspection.
Recommendation: Ensure the child activity center has a written exclusion policy on procedures to be followed when a child develops symptoms of an infectious illness while at the center. Ensure the exclusion policy includes a requirement for written clearance from the medical staff before a child with symptoms of infectious illness can be allowed in the child activity center. Post the policy at the entrance of the child activity center.
Item No.: 28
Site: Housekeeping-Deck 10 - Housekeeping Trolley
Violation: A box of opened latex gloves was stored inside the glassware container and on top of cleaned and sanitized glasses that were being distributed to the cabins.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The written OPRP specified a chlorine dioxide product for disinfection through an electrostatic sprayer. The contact times were specified, but the concentration was not. Although, this product was used directly from a bottle without dilution, this manufacturer sells different concentrations of this product. The data sheet for the one used on board specified the concentration was 2,000 ppm chlorine dioxide.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: 3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses).
Item No.: 10
Site: Recreational Water Facilities-Filter Housing & Hair & Lint Strainer Disinfection Records
Violation: The halogen residual for disinfecting the hair and lint strainer, strainer housing, and cartridge filter housing was not being recorded in the records.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Automated Monitoring
Violation: There were no chart recorders or electronic data loggers installed on the RWFs (besides the main pool) for monitoring free halogen and pH. In addition there were no alarms for low and high bromine levels.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment Protection
Violation: The RWFs did not meet the 2011 VSP Operations Manual requirements for antientrapment. Compliant drains for the whirlpools were observed but yet to be installed.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with gravity drainage and a single blockable drain or multiple drains less than 3 feet apart, provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a gravity drainage system.
Item No.: 07
Site: Potable Water-Mineralizer Air Gap
Violation: A plastic bottle was taped around the discharge end of the backwashing drain pipe which negated the effectiveness of the air gap. This was removed during the inspection. In addition, the cross connection control plan did not list this air gap and it had not been periodically inspected.
Recommendation: Ensure the potable water distribution system is maintained free of cross-connections. Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections. Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch). Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps.
Item No.: 08
Site: Potable Water-Testable Devices
Violation: The annual pressure test for 12 of the 28 testable backflow prevention devices had not been tested in over a year. These overdue testable devices were last tested on 26 May 2011.
Recommendation: Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
Item No.: 08
Site: Potable Water-Deck Chemical Dispensing Lockers
Violation: The backflow prevention devices on the bulkhead mounted chemical dispensers in the deck chemical lockers for housekeeping products were not on the cross-connection control program and were not periodically inspected.
Recommendation: Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
Item No.: 08
Site: Potable Water-Distilate and Permeate Water Lines
Violation: The distillate and permeate lines directed to the potable water system were not painted or striped in accordance with ISO 14726 (blue/gray/blue). These lines were striped blue only.
Recommendation: Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 20
Site: Galley-Deck 3 - Bakery / Pastry
Violation: Several pieces of paint had chipped away along the food contact surface of the mixer-shaft of the deck mounted mixer.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 08
Site: Galley-Deck 3 - Bakery / Pastry
Violation: Water was leaking from the two backflow prevention assemblies attached to the water purifiers used to add water to the mixing bowl of the large deck mounted mixer.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 20
Site: Galley-Deck 3 - Bakery / Pastry
Violation: Several pieces of metal plating along the food contact surface of the mixer shaft of the deck mounted mixer adjacent to the proofing cabinets had fallen off, or were loose which created a difficult to clean surface.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 21
Site: Galley-Combination Oven Gaskets
Violation: Numerous rubber gaskets along the door edges of combination ovens located in the crew galley, main galley, and specialty galley were cracked, especially along the bottom edges. One gasket on a combination oven in the crew galley failed along the bottom edge, which allowed a large volume of steam to escape.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 22
Site: Galley-Potwash
Violation: A gap along the bottom edge of the door to the potwash machine allowed water to spurt out of the machine while it was in use. In addition, the door could not be fully closed and appeared to be warped.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 36
Site: Buffet-Beverage Stations
Violation: The artificial light intensity around and behind counter-mounted equipment located in the officer's mess, crew mess, and staff mess was less than 110-lux of light.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 33
Site: Buffet-Officer's Mess Beverage Station
Violation: Soft sealant was used as coving material along the deck/equipment foundation for the consumer self-service buffet.
Recommendation: Ensure bulkheads and deckheads have smooth, hard finishes and light colored surfaces.
Item No.: 22
Site: Galley-Deck 6 - Warewash
Violation: Two wash manifolds of the in-use flight-type warewash machine were not seated correctly, which created leaks at the ends of the manifolds and diminished the effectiveness of the wash spray patterns.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Galley-Deck 12 - Garden Cafe - Warewash
Violation: The installed final rinse gauge (Manifold) of the flight-type warewash machine was out of calibration. According to the gauge, the temperature registered 220°F, but no steam was visible from the final rinse manifolds. The final sanitize rinse temperature by the inspector's thermocouple registered 167°F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 20
Site: Galley-Deck 12 - Garden Cafe
Violation: Gouges and scoring made a large round plastic cutting block difficult to clean.
Recommendation: Ensure surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 26
Site: Galley-Deck 12 - Garden Cafe
Violation: Food residue and a dark material soiled the gouges of the round cutting block.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Galley-Deck 6 - Bistro (Show) Galley
Violation: Corrosion covered two metal fasteners attached to the heating elements of the deep fat fryer.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 08
Site: Galley-Deck 6 - Gatsby Bar Pantry
Violation: A backflow prevention assembly was not installed on the carbonator.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment.
Item No.: 21
Site: Food Service General-Post-Soda Mix Lines
Violation: Insulation for post-soda mix lines installed through decks in numerous bars had features that were not easily cleanable. The adhesive used to affix (tape) the insulation was failing, which created gaps and seams that made cleaning difficult (this was noted where the lines splint and where the lines came through the deck penetration.
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 44
Site: Potable Water-Cross-connection Control Log
Violation: Several backflow prevention devices were not on the cross-connection control log (some of these were repeat violations from last inspection which had yet to be corrected), crew members could not identify the type or location of backflow prevention used for the mineralizer backwash process, 12 of the 28 testable backflow devices had not been tested annually. The cross-connection control log did not list all of the testable devices that had been previously tested.
Recommendation: Ensure the supervisor or person in charge of potable water operations on the vessel demonstrates to VSP?during inspections and on request-knowledge of potable water operations, is able to demonstrate this knowledge by compliance with Section 5 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 5 of the VSP 2011 Operations Manual as it relates to their assigned duties.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program