Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Asuka II Cruise Line: NYK Cruises Co., LTD Inspection Date: 06/25/2012 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Surveillance Log
Violation: The electronic AGE surveillance log did not match exactly the fields and format of the surveillance log provided in the 2011 VSP Operations Manual section 13.2.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 02
Site: Medical-Crew Reporting of GI Illness
Violation: A Purser with GI illness onset at 10 am on 13 June reported to the infirmary at 8:25 pm that day. A Cruise Staff with GI illness onset at 5 pm on 3 May reported to the infirmary at 9 am on 4 May. A Chief Waiter with GI illness onset at 6 pm on 19 April reported the symptoms to the infirmary at 8:35 on 20 April.
Recommendation: When any crew member (food or nonfood employee) meets the case definition for AGE, take the following actions: (1) restrict exposure to symptomatic crew member(s); (2) undergo a verbal interview with medical or supervisory staff, who will confirm their condition, provide facts and a written fact sheet about hygiene and handwashing, and instruct them to report immediately to medical if they develop illness symptoms; (3) complete a verbal interview daily with medical or supervisory staff until 48 hours after the ill crew members? symptoms began. Ensure that the first verbal interview is conducted within 8 hours from the time the ill crew member initially reported to the medical staff. If the asymptomatic immediate contact or cabin mate is at work, ensure that he or she must is contacted by medical or supervisory staff as soon as possible. Document the date and time of verbal interviews.
Item No.: 08
Site: Potable Water-Potable Water Bunkering and Production
Violation: Staff were not conducting pH tests every 4 hours during production of potable water or hourly when bunkering potable water.
Recommendation: After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least hourly during the bunkering of potable water. After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water.
Item No.: 08
Site: Potable Water-Potable Water Tank Maintenance
Violation: At the dry dock of 15-16 January 2012 potable water tanks 2 port and starboard and 3 port and starboard were spot painted, but there was no record other than photos describing this work, and there was no statement in the record that the manufacturers instructions were followed for the application, drying and curing of the coating used.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer); (2) manufacturers? recommendations for application, drying, and curing; and (3) written documentation that the manufacturers? recommendations have been followed for application, drying, and curing.
Item No.: 08
Site: Potable Water-Cross-Connection Control Listing
Violation: It was not clear if all air-gaps were identified in the plan, such as the mineralizer backwash.
Recommendation: Verify where air-gaps are present on the vessel and include them in the cross-connection control list and the inspections made annually.
Item No.: 08
Site: Food Service General-Ice Machine Chilled Water
Violation: The non-insulated chilled water piping on the rear panel of the ice machines was not uniquely identified to avoid confusion with potable water piping.
Recommendation: Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 10
Site: Recreational Water Facilities-Automatic Monitoring
Violation: None of the pools or whirlpool spas had monitoring analyzer and chart recorders installed directly from each pool or whirlpool before the compensation tank and none were installed on the return line from each pool or whirlpool before the compensation tank.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Recreational Water - Monitoring
Violation: The ship's electronic water testing kit was not able to monitor for total alkalinity. In addition, there were no secondary standard solutions onboard for verifying the accuracy of this test kit.
Recommendation: Ensure a test kit is available for testing water quality parameters, including free and total halogen levels (chlorine and bromine, where applicable), pH, and total alkalinity. Ensure that test kits are accurate to within 0.2 mg/L (ppm) for halogen and have a testing range of free residual halogen normally maintained in the RWF. Ensure test kits for pH are accurate to within 0.2. Ensure all reagents are not past their expiration dates. Where available, ensure appropriate secondary standards are onboard for electronic test kits to verify test kit operation.
Item No.: 10
Site: Recreational Water Facilities-Recreational Water - Monitoring
Violation: There was no monitoring of flow rates (no flow meters installed), combined chlorine, or total alkalinity in the pool, whirlpool spas, or grand spa.
Recommendation: Monitor and adjust the RWF?s flow rates, free and combined halogen levels, pH, total alkalinity, and clarity as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
Item No.: 10
Site: Recreational Water Facilities-Recreational Water - Shock Halogenation
Violation: The log for whirlpool spa and grand spa shock halogenation had pre-printed 10 ppm under the concentration column, and staff were not measuring and recording the free halogen residual at the beginning and end of shock halogenation.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-Recreational Water - Cleaning/Disinfection
Violation: The hair and lint strainers were not cleaned and disinfected weekly and neither was the housing for the hair and lint strainers. There were no records of sand filter housing or cartridge filter housing being cleaned and disinfected when sand or cartridge replacements were made in either the pool or whirlpool spas.
Recommendation: Clean, rinse, and disinfect the filter housing before the new filter media is placed in it. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures. Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Pool Safety
Violation: There were six open holes where water is injected near the lower wall sections of the Sea Horse Pool. These holes had no covers installed, although several had what appeared to be points on the upper and lower half meant for some type of attached screening or flow-thru cover. As they exist today these open channels represent a significant limb entrapment risk for children and adults and should be covered as soon as a suitable cover can be located.
Recommendation: Obtain and install covers for all uncovered holes along the side walls of the pool for the filling lines so water fills, but users cannot access the filling holes or the channels inside.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Spa and Grand Spa
Violation: The single drains in the whirlpool spas were not fully visible, but did not appear to meet the ASME/ANSI standards specified in table 6.7.1.2.2 of the VSP Operations Manual 2011. The dual suction fittings on the whirlpool spas were less than one meter apart and also did not appear to be compliant with ASME/ANSI A112.19.8. The single gravity drain in the pool appeared to be a compliant cover, but this should also be verified when possible.
Recommendation: For RWFs with gravity drainage and a single unblockable drain (per ASME A112.19.8), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with suction fittings and a single unblockable drain (per ASME A112.19.8-2007), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 16
Site: Buffet-Lido Garden
Violation: The posted time as a public health control plan did not include both the food set-up and discard times for each service period.
Recommendation: Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 19
Site: Other-Hamburger Grill - Noodle Pantry
Violation: The two bain marie's were operating at a rolling boil for noodle cooking, but generating so much condensation that drops were formed throughout the deckhead and the exhaust vent cover directly over the the open, boiling water. Staff were advised to wipe off the excessive condensation from above this equipment.
Recommendation: Staff should monitor the noodle bain marie more closely and ensure when condensation at the deckhead becomes heavy that the pans of food are fully covered and the deckhead and vent cover above are wiped dry.
Item No.: 22
Site: Galley-Crew Dishwash
Violation: The in-use conveyor dishwash machine had a wash gauge temperature of 168 °F, while a measure directly from the wash tank registered 158 °F.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 22
Site: Pantry-Pantries
Violation: There was no manufacturer's data plate installed on the new Hobart FX-80N model undercounter dishwash machines installed in the deck pantries.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 36
Site: Food Service General-Ice Machines in Galleys and Pantries
Violation: There was less than the minimum required 110 lux (10 foot candles) of artificial light behind ice machines througout the ice pantries and galley areas. Many of the galley machines were below the 110 lux minimum along both sides as well.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Pantry-Pantry Coffee Machines
Violation: The artificial light level behind the counter-mounted coffee machines in each deck pantry was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Pot Wash
Violation: The artificial light at the pot wash machine was below the minimum 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Galley-Pot Wash
Violation: The artificial light level behind and around the pot wash machine was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Hot Galley
Violation: The artificial light around and behind the large blast chiller was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Galley-Pastry
Violation: The artificial light level beside the floor mixer was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Buffet-Crew Mess Plate/Bowl Counter
Violation: The artificial light at the buffet counter used for clean plate and bowl pick-up was below the minimum 220 lux. There were no lights over this entire buffet counter.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 36
Site: Buffet-Crew Beverage Counters
Violation: The artificial light level behind the coffee and tea maker/dispensers was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 39
Site: Galley-Crew Dishwash
Violation: One live filth fly was observed on the canopy exhaust hood over the conveyor dishwash machine during use.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pastry
Violation: Three live fruit flies were observed on the bulkheads in the port/aft corner of this preparation area.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 39
Site: Galley-Pot Wash
Violation: One live filth fly was observed on the bulkhead at the soiled entry to the pot wash.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 41
Site: Food Service General-Outbreak Prevention and Response Plan (OPRP)
Violation: The ship's OPRP is titled Contingency Plan and contains attached documents detailing roles and responsibilities, such as the Frequency and in Charge Sheets. In these sheets there is a requirement for bar and restaurant equipment to be disinfected with chlorine at concentrations of 1,000-2,000 ppm (mg/L). These food equipment pieces cannot be disinfected to chlorine concentrations over 200 ppm.
Recommendation: Update the contingency plan to address all the new requirements in the 2011 VSP Operations Manual and ensure there is no guidance advising use of more than 200 ppm chlorine on food counters or food/drink related equipment.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The ships OPRP contingency plan has not been updated since 2006 and does not detail some of the points identified in the 2011 VSP Operations Manual. There was no procedures written to inform either the on board passengers of the gastrointestinal (GI) illness outbreak or those embarking the ship after an outbreak occurred. There was also not a clear guidance given on the manner of applying disinfectants or procedures to minimize dermal and respiratory exposures to the passengers. Chlorine is referred to as the primary disinfectant, but no cleaning steps were established prior to use of this disinfectant. Mikrobac 3 is also specified for use on upholstered surfaces and carpets, but no concentration or contact time was listed.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (1) Duties and responsibilities of each department and their staff for all the passenger and crew public areas; (2) Steps in outbreak management and control and the trigger for required action at each step. Ensure the triggers address a graduated approach to outbreak management in response to increasing case counts; (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (5) Procedures for returning the vessel to normal operating conditions after an outbreak; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
Item No.: 41
Site: Other-Crew Toilets
Violation: Although the crew public toilets have handwashing signs posted inside, they did not have signs posted advising use of paper towels/tissues to open the exit door. Some had no paper towel or tissue to use for this purpose, as they had electric hand-dryers installed.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free. Provide a dispenser for tissues with those toilets where paper towels are not provided and install a waste bin in or outside the restroom door for disposal.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program