Cruise Ship: Arcadia Cruise Line: P&O Cruises Inspection Date: 09/26/2012 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 11
Site: Medical-Crew Reporting
Violation: A food and beverage steward who experienced 5 loose stools beginning on 6 September at 0600 did not report to medical until 7 September at 1715. It was confirmed with the medical staff that the crew member worked her full shift on 6 September and 7 September.
Recommendation: Ensure food employees who have conditions or symptoms of boils, open sores, infected wounds, diarrhea, jaundice, fever, vomiting, sore throat with fever, or discharges from the nose or mouth report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
Item No.: 08
Site: Potable Water-Distallate Water Lines
Violation: The distillate lines directed to the potable water system were not painted or striped in accordance with ISO 14726 (blue/gray/blue). These lines were striped blue only.
Recommendation: Stripe or paint distillate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 10
Site: Recreational Water Facilities-Flow Meters, Turnover Rates, Bather Loads
Violation: Turnover rates and bather loads for all of the RWFs were being calculated from theoretical pump rates and not by the actual flow rates as measured by flow meters. Flow meters were not available on the RWFs.
Recommendation: For RWFs with skim gutters, ensure that the fill level of the RWF is to the level of the skim gutters. Design recirculation systems and equipment, including chemical control equipment, UV disinfection systems, filter, and pumps to maintain adequate water chemistry control while operating at the following minimum turnover rates: (1) swimming pool (VSP 2005 Construction Guidelines or earlier): 6 hours; (2) swimming pool (VSP 2011 Construction Guidelines or later): 4 hours; (3) children's pool: 0.5 hours; (4) wading pool: 1 hour; (5) whirlpool spa: 0.5 hours; (6) spa pool: 2 hours; (7) interactive RWF or activity pool less than 610 millimeters (24 inches) deep: 1 hour; (8) interactive RWF or activity pool greater than 610 millimeters (24 inches) deep: 2 hours; and (9) baby-only water facility: 0.5 hours. Ensure an RWF slide that is combined with a pool has a turnover rate that matches the rate for the pool. Maintain documentation on the maximum bather load for each RWF. Ensure the maximum bather load is based on the following factor: one person per five gallons (19 liters) per minute of recirculation flow. Monitor and adjust the RWF?s flow rates as recommended by the manufacturer and to maintain optimum public health protection and water chemistry.
Item No.: 10
Site: Recreational Water Facilities-Hair and Lint Stainer
Violation: There were no records indicating that the hair and lint strainer and the hair and lint strainer housings at the RWFs were being cleaned, rinsed, and disinfected weekly.
Recommendation: Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
Item No.: 10
Site: Recreational Water Facilities-Halogen and pH Analyzer Probe Locations
Violation: The sample line locations for free halogen residual and pH probes for the swimming pools and the spa pool were located after the compensation tank.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.
Item No.: 10
Site: Recreational Water Facilities-Water Quality
Violation: There were no records indicating the date and time for the water dumping at both the spa pool and whirlpools.
Recommendation: Change spa pool water as often as necessary to maintain proper water chemistry. Change the water at least every 30 days. Record the date and time of whirlpool spa and spa pool water changes in the log.
Item No.: 10
Site: Recreational Water Facilities-Shock Bromination
Violation: Approximately, 10 shock bromination records for the whirlpools and the spa pool indicated that the bromine residual did not remain above 10 ppm for at least 1 hour during the months of September and October.
Recommendation: Increase the free residual halogen to at least 10.0 mg/L (ppm) and circulate for at least 1 hour every 24 hours. Test the free residual halogen both at the start and completion of shock halogenation. Superhalogenate the water in the entire RWF system to 10 ppm to include the whirlpool spa/spa pool tub, compensation tank, filter housing, and all associated piping before starting the 1-hour timing.
Item No.: 10
Site: Recreational Water Facilities-Safety Signage
Violation: The recreational water facility signage did not meet the current requirements of the 2011 VSP Operations manual.
Recommendation: Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (1) do not use these facilities if you are experiencing diarrhea, vomiting, or fever; (2) no children in diapers or who are not toilet trained; (3) shower before entering the facility; and (4) bather load #. For children?s RWF signs, include the exact wording ?TAKE CHILDREN ON FREQUENT BATHROOM BREAKS? or ?TAKE CHILDREN ON FREQUENT TOILET BREAKS.? In addition to the safety sign requirements in section 6.7.1.1.1, install a sign at each whirlpool spa and spa pool entrance listing precautions and risks associated with the use of these facilities. Include, at a minimum, cautions against use by the following: (1) individuals who are immunocompromised; (2) individuals on medication or who have underlying medical conditions such as cardiovascular disease, diabetes, or high or low blood pressure; and (3) pregnant women, elderly persons, and children. Additionally, caution against exceeding 15 minutes of exposure.
Item No.: 10
Site: Recreational Water Facilities-Shepherd's Hook
Violation: The Shepherd's hook at both swimming pools were not long enough to reach the center of the deepest portion of the pools from the side plus 2 feet. The current hooks were telescoping.
Recommendation: Provide a rescue or shepherd?s hook and an approved flotation device at a prominent location (visible from the full perimeter of the pool) at each RWF that has a depth of 1 meter (3 feet) or greater. Mount these devices in a manner that allows for easy access during an emergency. Ensure the pole of the rescue or shepherd?s hook is long enough to reach the center of the deepest portion of the pool from the side plus 2 feet. Ensure it is a light, strong, nontelescoping material with rounded, nonsharp ends. Ensure the approved flotation device includes an attached rope that is at least 2/3 of the maximum pool width.
Item No.: 10
Site: Recreational Water Facilities-Antientrapment Drain Covers
Violation: It was unclear whether the single gravity drain and the two suction drain covers at the whirlpools were in compliance with ASME A112.19.8 standards. The two suction drains at the whirlpools were less than 3 feet apart with no secondary antientrapment requirement such as a safety vacuum release system or an automatic pump shut off system. The swimming pools and spa pool gravity drain covers also did not meet the antientrapment requirements. The drains were gravity, multiple, with no alarm. There were also suction drains at all of the pools and it was unclear if these drain covers met the antientrapment requirements. These suction drains were multiple, greater than 3 feet apart, with no secondary antientrapment requirement.
Recommendation: For RWFs with gravity drainage and multiple drains (2 or more drains greater than 3 feet apart), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with gravity drainage and a single unblockable drain (per ASME A112.19.8), provide either a standard design (not compliant with ASME A112.19.8) drain cover and an alarm, or an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. Ensure the alarm is audible and sounds in both a continuously manned space and at the RWF. Ensure this alarm is for all draining: accidental, routine, and emergency. For RWFs with gravity drainage and a single blockable drain or multiple drains less than 3 feet apart, provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a gravity drainage system. For RWFs with suction fittings and multiple drains (2 or more drains per pump with drains greater than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover. For RWFs with suction fittings and a single unblockable drain (per ASME A112.19.8-2007), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system. For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan (OPRP)
Violation: The OPRP did not include procedures for protecting passengers and crew members from respiratory and dermal exposures while using Virox to disinfect common areas with misting machines.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage.
Item No.: 36
Site: Pantry-Ice Machines
Violation: The light intensity behind deck mounted ice machines in deck pantries could not be raised to the required 110 lux of light.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Pantry-Ice Machines
Violation: The light intensity behind and around the deck mounted ice machines in the Piano Bar pantry and Pub pantry could not be raised to the required 110 lux of light.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 08
Site: Pantry-Refrigerant Water Lines
Violation: The refrigerant water lines to the deck mounted ice machines in the deck and bar pantries were not identified as non-potable.
Recommendation: Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 22
Site: Pantry-Pantry # 4.6.05
Violation: There was no data plate for the undercounter dishwash machine located in this pantry.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 33
Site: Pantry-Piano Bar
Violation: Green electrical cables were coiled on the deck inside the technical compartment to the espresso machine. Water was pooling on the deck underneath the electrical cables.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Do not use carpet in these areas.
Item No.: 16
Site: Food Service General-All Galley and Preparation Areas
Violation: The posted, time as a public health control plans, did not include the management of potentially hazardous foods in pans which were set alone or in ice baths on the various counters in the food preparation areas. These counters were also used for preparation of foods not on time control. The time control plans stated that no labels would be used because the service periods were less than 4 hours. The pans of food observed had no discard labels on them. Examples include: three types of fried potatoes in hotel pans, mueslix in hotel pans, and blanched pasta in hotel pans.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 36
Site: Food Service General-Galleys and Preparation/Service Areas
Violation: The artificial light levels were below the minimum of 110 lux behind and around equipment in the following areas: deck 2 - hot galley forward, behind the microwave oven; pastry, behind the two stack ovens; Ocean Grill, behind the ice machine at the beverage station; Neptune Bar pantry, behind the ice machine; Aquarius Bar Pantry, behind the ice machine and beside the hood type glasswash machine.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 21
Site: Galley-Galleys and Preparation Counters
Violation: Power cables to the following counter mounted equipment were draped on the counter below: microwave oven in deck 2 hot galley forward, Bremen coffee machine in the lower Meridian Restaurant pantry beverage station, steamer in the pastry service section of deck 3 galley, and the Bremen coffee machine in the coffee pantry in deck 3 galley.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 28
Site: Galley-Deck 2 Galley - Pastry
Violation: The soap dispenser installed at the handwash station near the entrance was positioned too close to the adjacent food preparation counter. When using the soap dispenser water was able to drip onto the counter.
Recommendation: Relocate the soap dispenser so that water can not contaminate the preparation counter.
Item No.: 36
Site: Galley-Deck 2 Galley - Pastry
Violation: The artificial light level on the clean pot rack beside the stack oven appeared to be below the minimum 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 21
Site: Galley-Deck 2 Galley - Ocean Grill Section
Violation: The small black stone appetizer plates were stored in the undercounter warmer with the other previously cleaned plates. One of these had a glue residue on the surface, while the remaining ones had a foam padding material secured to one side with glue. This pad was absorbent and not durable. Also, due to the heat from the cabinet, the glue was melting and allowed for the pads to easily peel off. Staff stated these foam pads were secured to keep the plates from moving on the preparation station when used to transfer small bowls of soup during service.
Recommendation: Remove these foam pads from the stone plates and remove all glue residue from each. Use another method, such as a clean washable napkin on the counter to prevent movement of the stone plates during service.
Item No.: 16
Site: Galley-Deck 2 Galley - Ocean Grill Section
Violation: One plastic hotel pan of cut raw spinach was found inside upright reach-in refrigerator ARG-3. The spinach had food temperatures of 44 °F. Staff removed the pan for immediate blast chilling.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 16
Site: Dining Room-Ocean Grill Menu
Violation: The menu for the Ocean Grill Restaurant included a consumer advisory for the animal-derived foods that can be served raw or undercooked, but not all of these items had an asterisk beside them to connect with the consumer advisory.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 33
Site: Galley-Deck 2 Galley
Violation: There was heavy pitting in the deck surface throughout the sauce bench section and the pot wash, and to a lesser extent in the other areas of the galley. This left the surface difficult to clean.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 22
Site: Galley-Deck 2 Galley - Pot Wash
Violation: The pot wash machine was in disrepair, and although staff were doing the work manually, the accumulation of soiled items was overwhelming the space, making it difficult to move. Staff later transferred many of the soiled items up to the deck 3 galley pot wash.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use. Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 36
Site: Galley-Deck 2 Galley - Hot Galley
Violation: The artificial light level near the two port side combination ovens should be verified, as both appeared to be below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 22
Site: Galley-Deck 2 Galley - Dishwash
Violation: The in-use flight-type conveyor dishwash machine was not producing any water spray from the final rinse nozzles in either the lower or upper final hot water-sanitizing spray arms. Staff repaired the machine later in the inspection and the upper spray arm nozzles showed visible water spray and met the final rinse temperature requirements.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 24
Site: Galley-Deck 2 Galley - Dishwash
Violation: The in-use flight-type conveyor dishwash machine was not producing any water spray from the final rinse nozzles in either the lower or upper final hot water-sanitizing spray nozzles. Staff repaired the machine later in the inspection and at least the upper spray arm nozzles showed visible water spray and met the final rinse temperature requirements.
Recommendation: In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F) or less than: (1) 74°C (165°F) for a stationary rack, single-temperature machine; (2) 82°C (180°F) for all other machines. Ensure the utensil surface temperature is not less than 71°C (160°F) as measured by an irreversible registering temperature indicator.
Item No.: 22
Site: Galley-Deck 3 Galley - Pot Wash
Violation: The pot wash machine data plate indicated the complete cycle time for both wash and rinse, rather than listing the required times for each separately.
Recommendation: Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine?s design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
Item No.: 16
Site: Buffet-Belvedere Dessert Counter Starboard
Violation: One hotel pan of opened and large cut pieces of 3 different cheeses was inside the undercounter reach-in refrigerator with a 3 day discard label. The lower refrigerator section was on time control according to the time control plan and the label affixed. The cheeses had temperatures of 44-45 °F.
Recommendation: Ensure that the time control plan is being followed.
Item No.: 16
Site: Galley-Time Control Plan
Violation: The written and posted, time as a public health control plan, stated that all potentially hazardous foods in back-up hot holding units were on time control, but the plan did not specifically list all the units where this applied. Specifically, there were foods held hot for back-up, such as fish in the oven, chicken in the tilt braising pan, rice in the tilt braising pan, soups in two different steam kettles, and sauces in sauce pans on the range top. None of these units were labeled or noted in the time control plan.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 21
Site: Galley-Belvedere Galley - Starboard
Violation: In the starboard/forward specialty area the steam pipe insulation wrapping was severely damaged and the insulation was unprotected in undercounter technical compartment Bev-3.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Belvedere Galley - Hot Galley
Violation: The lower far left door on undercounter reach-in refrigerator BE-6, was warped and did not seal tightly to the door frame in the lower half when the door was fully shut. The gap at the lower door was large enough for a folded paper to be passed into the inside of the refrigerator.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 33
Site: Buffet-Belvedere - Aft Beverage Station
Violation: The deckhead in this area was soiled in various areas with dirt and food debris.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 39
Site: Buffet-Belvedere - Aft Beverage Station
Violation: Two live fruit flies were observed on the deckhead near the hot water dispenser, and they appeared to be feeding on food debris on the deckhead.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program