Item No.:
28
|
|
Site:
Galley-Beverage Station
|
|
Violation:
A stack of plates by the toaster were protected, but upright and not completely dry. The plates were removed.
|
|
Recommendation:
After cleaning and sanitizing, ensure equipment and utensils are air dried or adequately drained before contact with food. Store clean equipment and utensils in a self-draining position that allows air drying, and covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Galley-Hot Line
|
|
Violation:
In the bain marie technical compartment on the port end of the hot line, the orange-colored electrical conduit was too long and was on the deck below the compartment.
|
|
Recommendation:
Shorten the electrical lines or secure them above the deck to allow for cleaning.
|
|
|
Item No.:
37
|
|
Site:
Galley-Hot Line
|
|
Violation:
There was condensation on the underside of the shelf over the center and starboard bain marie units. The water inside both was boiling and there were no covers over the open areas. The water temperature was lowered and there was no food impacted.
|
|
Recommendation:
Ensure the temperature is monitored to prevent the water from boiling and place covers over empty heated bain marie compartments to prevent steam from escaping.
|
|
|
Item No.:
08
|
|
Site:
Galley-Pastry Distribution
|
|
Violation:
The chill water lines to the ice cream machine were not labeled. This was corrected during the inspection.
|
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
|
Item No.:
22
|
|
Site:
Galley-Dishwash
|
|
Violation:
The rack conveyor dishwash machine data plate indicated the speed in racks per hour.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
22
|
|
Site:
Galley-Pot Wash
|
|
Violation:
There was no cycle time listed on the data plate for the pot wash machine.
|
|
Recommendation:
Ensure a warewashing machine is provided with an easily accessible and readable data plate affixed to or posted adjacent to the machine that indicates the machine's design and operating specifications including the: (1) wash tank, rinse tank(s) if present, and final sanitizing rinse temperatures; (2) pressure required for the fresh water sanitizing rinse unless the machine is designed to use only a pumped sanitizing rinse; (3) conveyor speed in feet per minute or minimum transit time for belt conveyor machines, minimum transit time for rack conveyor machines, and wash and final sanitizing rinse times as specified by the manufacturer for stationary rack machines.
|
|
|
Item No.:
30
|
|
Site:
Galley-Galley Worker Toilet
|
|
Violation:
The door to the toilet did not shut completely. This was corrected during the inspection.
|
|
Recommendation:
Ensure toilet rooms are completely enclosed and have tight-fitting, self-closing doors which are kept closed except during cleaning or maintenance.
|
|
|
Item No.:
17
|
|
Site:
Galley-Blast Chiller
|
|
Violation:
There was stew meat, ground meat, and red bell pepper soup in the under counter blast chiller and there was no documentation of the cooling for any of the items. Staff stated that the items had gone into the blast chiller in the morning and the internal temperatures ranged from 48°F to 55°F.
|
|
Recommendation:
Ensure logs documenting cooked potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days from the date the food was placed in the cooling process.
Ensure logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Beverage Stations
|
|
Violation:
The light intensity was less than 110 lux behind the counter-mounted equipment at the beverage stations in the crew and officer's messes.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
21
|
|
Site:
Galley-Pool Grill
|
|
Violation:
The hot rock oven was too close to the bulkhead to allow for inspection and cleaning behind the oven.
|
|
Recommendation:
Ensure equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead.
|
|
|
Item No.:
36
|
|
Site:
Galley-Pool Grill
|
|
Violation:
The light intensity was less than 110 lux to the right of the hot rock oven.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
|
Item No.:
16
|
|
Site:
Buffet-Egg Station
|
|
Violation:
There was no consumer advisory at the egg station where eggs could be cooked to order. There was a sign that stated eggs could be served undercooked and a consumer advisory at the entry to the buffet.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., "oysters on the half-shell," "hamburgers," "steaks," or "eggs"); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Pre-Pump Filters and Housings
|
|
Violation:
The records for the disinfection of the pre-pump filters did not include a contact time and the documentation did not include disinfection of the housings. According to the staff, the contact time was at least 1 minute and the housings were also disinfected.
|
|
Recommendation:
Clean, rinse, and disinfect the hair and lint strainer and hair and lint strainer housing on all RWFs weekly. Ensure disinfection is accomplished with an appropriate halogen-based disinfectant. At a minimum, use a 50-ppm solution for 1 minute, or equivalent CT value. Maintain records on all inspection and cleaning procedures.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Antientrapment Protection for Whirlpools
|
|
Violation:
Not all of the covers installed on the suction outlets for the therapy pumps on the two whirlpools were certified for antientrapment. Documentation indicated that 10 certified covers had been ordered. SVRS devices were installed for each of the pumps.
|
|
Recommendation:
For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Whirlpool Safety Signs
|
|
Violation:
The signs for the two whirlpools included a statement that children under the age of 12 required adult supervision. VSP considers those under 16 years of age to be children for the purpose of whirlpool safety sign requirements.
|
|
Recommendation:
Change the sign to indicate the age for requiring adult supervision is under 16.
|
|
|
Item No.:
41
|
|
Site:
Medical-Public Toilet Signs
|
|
Violation:
The toilet room used by passengers and crew in the medical center did not have signs advising users to wash their hands or to use a tissue or paper towel to open the door.
|
|
Recommendation:
Provide the passenger and crew public toilets with a handwashing station that includes: (4) A sign advising users to wash hands. Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
|
|
|
Item No.:
36
|
|
Site:
Pantry-Deck 7 Forward
|
|
Violation:
The light intensity was less than 110 lux behind the ice machine.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|