Cruise Ship: Caledonian Sky Cruise Line: Salen Ship Management AB Inspection Date: 10/07/2012 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Potable Water-Storage Tanks
Violation: Sample cocks were located near the top of the four potable water storage tanks. This makes it difficult to collect the proper halogen residual and microbiological samples for assuring the condition of the water in these tanks. The tanks cannot be individually drained and chlorinated to remediate problems, either.
Recommendation: See VSP Tank Construction Guidelines for details.
Item No.: *
Site: Potable Water-Backflow Prevention
Violation: Verification is needed on the suitability of the new backflow prevention devices installed for the applications where they are connected.
Recommendation: Protect the potable water system against backflow or other contamination by backflow prevention devices or air gaps. Ensure the permeate lines and distillate lines directed toward the potable water system are also protected.
Item No.: 02
Site: Medical-
Violation: The AGE surveillance log entry for each passenger or crew member must contain the following information in separate columns: Date of the first medical visit or report to staff of illness; Time of the first medical visit or report to staff of illness; Case identification number; Person's name; Person's age; Person's sex; Designation as passenger or crew member; Crew member position or job on the vessel, if applicable; Cabin number; Meal seating information; DATE OF ILLNESS ONSET; TIME OF ILLNESS ONSET; Illness symptoms, including the presence or absence of the following selected signs and symptoms - with a separate column for each of the following: Number of episodes of diarrhea in a 24-hour period; Number of episodes of vomiting in a 24-hour period; Bloody stools; Recorded temperature; Abdominal cramps; Headaches; Muscle aches; Entry (yes/no) for whether this was a reportable case; Entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; Presence of underlying medical conditions that may affect interpretation of AGE; for example, diabetic diarrhea, inflammatory bowel disease, gastrectomy, antibiotic-induced diarrhea, vomiting from chemotherapy, ear infections in children or others. The AGE surveillance log must contain the above information in this exact order and entered in the template in Annex 13.2.2. The log data must be exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Any additional data fields must be entered only outside of the form margins when exported to VSP.
Recommendation: Ensure the AGE surveillance log entry for each passenger or crew member contain the following information in separate columns: (1) Date of the first medical visit or report to staff of illness; (2) time of the first medical visit or report to staff of illness; (3) case identification number; (4) person?s name; (5) person?s age; (6) person?s sex; (7) designation as passenger or crew member; (8) crew member position or job on the vessel, if applicable; (9) cabin number; (10) meal seating information; (11) date of illness onset; (12) time of illness onset; (13) illness symptoms, including the presence or absence of the following selected signs and symptoms, with a separate column for each of the following: (a) number of episodes of diarrhea in a 24-hour period; (b) number of episodes of vomiting in a 24-hour period; (c) bloody stools; (d) recorded temperature; (e) abdominal cramps; (f) headaches; (g) muscle aches; (14) entry (yes/no) for whether this was a reportable case; (15) entry (yes/no) for antidiarrheal medications sold or dispensed by designated medical staff; (16) presence of underlying medical conditions that may affect interpretation of AGE. Ensure the AGE surveillance log contains the above information in the exact order and is entered in the template in Annex 13.2.2. Ensure that the log data is exported in the exact order as in the example template in Annex 13.2.2 with analyzable formats such as Excel or Access. Ensure that any additional data fields are entered only outside of the form margins when exported to VSP.
Item No.: 06
Site: Potable Water-Far Point Chart Recorder
Violation: The charts for 9/20 and 9/20 were not changed at 24 hour intervals resulting in an overlapping record with day before. Maintenance and monitoring system has been changed since these two occurrences to reduce the chance of their recurrence as verified by subsequent records review.
Recommendation: Change, initial, and date halogen analyzer-chart recorder charts daily.
Item No.: 08
Site: Potable Water-Production
Violation: No records were available to show that the permeate water from the reverse osmosis system had been maintained at or above 2 PPM before storage in the potable water tanks.
Recommendation: After the free residual halogen level of at least 2.0 mg/L (ppm) and pH level not exceeding 7.8 have been reached, monitor the free residual halogen and pH at least once every 4 hours during the production of potable water. Maintain accurate records of production and bunkering monitoring aboard for 12 months and ensure these records are available for review during inspections.
Item No.: 08
Site: Potable Water-Storage Tanks
Violation: Independent testing organization verification of the listing of the coating suitability of its use.
Recommendation: Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer).
Item No.: 08
Site: Potable Water-Storage Tanks
Violation: The potable water storage tank disinfection records did not specify the contact time (reported to be 24 hours) and the final residual before returning the tank to service.
Recommendation: Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
Item No.: 08
Site: Potable Water-Potable Water Piping
Violation: The permeate line prior to chlorination of this water was not striped blue-gray-blue to differentiate it from potable water piping. Verify that all potable water lines in the engine room are striped with blue stripes.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
Item No.: 08
Site: Food Service General-All Food Areas Backflow Prevention
Violation: There was no backflow prevention device on any of the counter model water boilers in the galley and pantry and none on the older bulkhead mounted dispenser in the main galley. There was no backflow preventers on the combination ovens in the galley or bakery. A non-continuous pressure model backflow preventer was installed between two valves on the water supply to the Hoshizaki ice machine in the Veranda pantry. No backflow preventer was installed on the provisions vegetable preparation sink water supply piping, yet there was a clear plastic hose connected to the sink faucet and the other end coiled in the bottom of the sink basin.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (10) food service equipment; and (28) any other connection to the potable water system where contamination or backflow can occur.
Item No.: 13
Site: Galley-Hot Galley
Violation: A cook was observed using a food preparation sink to rinse debris off his hands after cutting meat. There were two handwash stations within 15 feet of his position.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (4) Food employees are effectively cleaning their hands.
Item No.: 13
Site: Galley-Hot Galley
Violation: A cook was observed cutting raw beef at a preparation counter into chunks for soup. Beside the raw beef on the same counter were two large covered hotel pans of raw chicken, one small covered hotel pan of raw calamari, and a small covered hotel pan of raw shrimp which had a covered hotel pan of raw ground turkey meat stored directly on top. All pans were removed and placed back in refrigeration to be cut and prepared one at a time.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (12) Employees are properly trained in food safety as it relates to their assigned duties.
Item No.: 13
Site: Galley-Hot Galley
Violation: Staff stated that under the time control plan foods placed in the combination oven were cooked or reheated in temperature, but held hot for service under time control after. One large hotel of cooked rice, said to be reheating by the cook was prepared and served during the breakfast service. The rice was discarded immediately upon learning it was not in fact discarded after breakfast as required when using time control.
Recommendation: Ensure the supervisor or person in charge of food operations on the vessel monitors that: (12) Employees are properly trained in food safety as it relates to their assigned duties.
Item No.: 16
Site: Food Service General-Galleys and Pantry's
Violation: The posted time control plans in all food areas were not accurate in terms of describing the time control system used on this ship. They referred to other ships within this cruise line which have different facilities on board, such as a Veranda Galley. The plans had no set-up or discard times and none described the specific units where time control was used, such as bain maries and combination ovens. There was no mention of the use of counters and overshelves for placement of hot and cold potentially hazardous foods in pans or plates, and equipment like the combination ovens and the counter model milk dispenser were not labeled as time control units or listed in the plans. Likewise the pans of food were not labeled with discard times.
Recommendation: If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (1) Has an initial temperature of 5°C (41°F) or less or 57°C (135°F) or greater before placement on time control. (2) Is not be placed on temperature control again. (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours. and (4) Is discarded within 4 hours of placement on time control. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (1) Includes set-up and discard times for each outlet. (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such). (3) Describe or show the flow of potentially hazardous food from when last in temperature control to placement in time control and discard.
Item No.: 16
Site: Food Service General-Consumer Advisory in Menu's
Violation: The consumer advisory in the various meal menu's for both the main dining room and the Veranda Buffet did not refer to persons with certain medical conditions. Additionally, although there was an asterisk beside the advisory, there were asterisks used throughout the pages meant only to separate meal sections (appetizers, soups, main course, desserts). Lastly, the breakfast menu identified only eggs as a risk for undercooked animal food, but there was also cold smoked salmon on the same menu.
Recommendation: If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure the consumer is informed by way of disclosure using menu advisories, placards, or other easily visible written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form. Locate the advisory at the outlets where these types of food are served. Ensure that raw shell egg preparations are not used in uncooked products as described in section 7.3.3.2.3. Ensure that disclosure is made by one of the two following methods: (1) On a sign describing the animal-derived foods (e.g., ?oysters on the half-shell,? ?hamburgers,? ?steaks,? or ?eggs?); AND that they can be cooked to order and may be served raw or undercooked; AND a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, poultry may increase your risk for foodborne illness, especially if you have certain medical conditions. Ensure the advisory is posted at the specific station where the food is served raw, undercooked, or cooked to order OR (2) On a menu using an asterisk at the animal-derived foods requiring disclosure and a footnote with a statement indicating that consuming raw or undercooked meats, seafood, shellfish, eggs, milk, or poultry may increase your risk for foodborne illness, especially if you have certain medical conditions.
Item No.: 16
Site: Preparation Room-Bakery Counter
Violation: A large film covered hotel pan filled with sugar glazed rolls with shredded cheese on top (Ensaymada Bread) was set on the pastry counter. Staff stated that this was prepared in the morning by the baker and was not to be served until dinner. As it was at 73 °F and 4 hours had already elapsed it was discarded.
Recommendation: Maintain potentially hazardous foods at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less.
Item No.: 17
Site: Galley-Cold Pantry
Violation: Both cold smoked salmon and gravlax were served to passengers in ready-to-eat form, but there was no letter on board to certify these products were free of parasites due to the freezing temperature and time involved in storage or the manner in which the fish were raised.
Recommendation: If raw, raw-marinated, partially cooked, or marinated partially cooked fish are served in ready-to-eat form, ensure: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, ensure there is a designation on the outer packaging for the parasite-free fish.
Item No.: 19
Site: Provisions-Vegetable Preparation
Violation: The preparation sink drain pipe was directly connected to the drainage system at the deck with no air-break or air-gap.
Recommendation: Ensure drain lines from all fixtures and sinks that are used, designed for, or intended to be used in the preparation, processing, storage, or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air gap or air break.
Item No.: 21
Site: Preparation Room-Butcher Shop
Violation: There was a gap between the door gasket and frame when the upright reach-in refrigerator was fully closed. This gap was large enough for several folded sheets of paper to pass through to the inside of the refrigerator.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 21
Site: Buffet-Veranda Buffet Counter
Violation: The grill grease pan housing interior was not fully steel lined and exposed insulation material was present along the top surface of the entire housing. There were open voids throughout and a difficult deep channel to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Hot Galley
Violation: The steam pipe cloth insulation in the undercounter technical compartment for the bain marie was in complete disrepair, with pieces hanging on the piping and others found below on the deck drain cover.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Food Service General-Galley, Pantry, and Bar Pantry
Violation: Power cables and braided steel flexible water supply piping to the various counter model equipment were draped on the top of the counters below and behind those equipment pieces (coffee machines, water boilers).
Recommendation: Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure nonfood-contact surfaces are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Hot Galley
Violation: There was a hole in the upper interior panel of the large flat grill grease pan housing where the grease chute entered.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Galley-Hot Galley
Violation: The small flat-top grill grease pan housing had large open voids at the entry point on both sides which was difficult to access and clean. In addition, the housing itself was a deep channel which was difficult to fully clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 22
Site: Galley-Main Galley - Potwash
Violation: During active manual pot washing the rinse sink was so filled with soap as to be confused as another rinse sink. Staff drained this sink and refilled with fresh rinse water.
Recommendation: Provide a sink with at least three compartments for manually washing, rinsing, and sanitizing equipment and utensils. Maintain the manual warewash sink set-up and operation as a sequence of wash, rinse and sanitize.
Item No.: 22
Site: Galley-Potwash
Violation: The soiled staging counters were stacked full of soiled items and a large soiled hotel pan was set directly on the deck with soiled cutting boards and utensils inside. A loose serving ladle soiled with heavy chocolate was setting on the deck beside the hotel pan. Staff later moved all these items onto a proper deck stand placed in that area.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
Item No.: 22
Site: Food Service General-All Food Area Sanitizing Solutions
Violation: A disposable sponge cloth was used for sanitizing in all the sanitizing buckets used throughout the food areas of the ship.
Recommendation: Do not use sponges in contact with cleaned and sanitized or in-use food-contact surfaces.
Item No.: 22
Site: Pantry-Veranda Buffet Pantry - Dishwash
Violation: The undercounter model single rack dishwash machine was posted out of order. It has not been used in over a month according to staff.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
Item No.: 26
Site: Galley-Cold Pantry
Violation: The previously cleaned counter model slicer had food residue on the lower slicer blade guard interior section, where a small crevice makes cleaning difficult.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Potwash
Violation: A previously cleaned hotel pan, two small mandolin slicers, and a strainer found on the clean storage rack were soiled with food particles. They were re-washed immediately.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-Coffee and Tea Station
Violation: The interior of the dispensing nozzle for the previously cleaned cold milk dispenser on the counter was soiled with milk residue.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-Hot Galley
Violation: The steam pipe cloth insulation in the undercounter technical compartment for the bain marie was soiled and in complete disrepair, with pieces hanging on the piping and others found below on the deck drain cover.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Hot Galley
Violation: There was a layered accumulation of old grease and heavy food debris inside the large flat-top grill grease pan housing, both in the crevices at the lower entry sides and throughout which was well over one day's accumulation.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Galley-Hot Galley
Violation: The gap between the upper edge of the large flat grill and the edge of the range top beside was heavily soiled with accumulated grease and food debris. Staff demonstrated that the range was removable, so these two side pieces could be easily accessed and cleaned during non-preparation periods.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-Veranda Buffet Counter
Violation: The interior surfaces of the grill grease pan housing were heavily soiled with accumulated grease and food debris.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Provisions-Vegetable Preparation
Violation: There was an undershelf below the preparation sink and counter where previously cleaned pans were stored. The shelf surface was soiled with water mixed with food debris.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination.
Item No.: 28
Site: Galley-Cold Pantry
Violation: The paper towel dispenser at the handwash station was positioned too close to the adjacent food preparation counter, and the counter became wet when reaching for a paper towel following handwashing.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; and (2) in a location where they are not exposed to splash, dust, or other contamination. Protect food from contamination that may result from a physical, chemical, biological origin.
Item No.: 30
Site: Food Service General-All galleys, pantries, bars and food areas
Violation: The handwash station signs did not state wash hands often or wash hands frequently in any of the food areas throughout the ship. No handwash sign was provided at the Caledonian Lounge handwash station.
Recommendation: Post a sign over handwashing sinks stating "WASH HANDS OFTEN" in a language that the food employees understand.
Item No.: 33
Site: Galley-Main Galley and Veranda Pantry
Violation: There were loose deckhead profiles in various areas of the galley and Veranda pantry which made cleaning difficult. In addition, there were bulkheads in both areas with a ribbed plastic power cable conduit which was screwed to the bulkheads with bracing pieces. These were too tight to allow room to clean behind. The cable conduit ended in many of these at an electrical control switch for equipment such as salamander broilers.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Provisions-Provisions and Crew Buffet
Violation: Small plastic racks were used as deck stands for foods stored throughout the various provisions rooms and dry stores. These racks were flat and there were no raised legs to allow easy cleaning of the deck below. A dishware rack set on the deck was used to store soiled items at the crew buffet dishwash.
Recommendation: Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck. Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing. Ensure nonfood-contact surfaces are designed and constructed to allow easy cleaning and to facilitate maintenance and the area where it is used.
Item No.: 33
Site: Preparation Room-Bakery Hood
Violation: There was a loose deckhead panel within the exhaust vent hood for the two combination ovens which created a large open void.
Recommendation: Ensure deckheads in food preparation areas are maintained in good repair.
Item No.: 33
Site: Preparation Room-Vegetable Preparation
Violation: The power cable to the Tina defrosting refrigerator was draped on the deck, making cleaning of that area difficult.
Recommendation: Install exposed utility service lines so they do not obstruct or prevent cleaning.
Item No.: 34
Site: Buffet-Veranda Buffet Counter
Violation: The ice cream dipper well was not working and has been in disrepair for a long time according to staff.
Recommendation: Ensure a plumbing system in a food area is maintained in good repair.
Item No.: 36
Site: Galley-Coffee and Tea Station
Violation: The artificial light level behind and beside the KYLCITY upright reach-in refrigerator was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 36
Site: Dining Room-Movable Buffet Station
Violation: The artificial light level at the buffet was less than the minimum 220 lux.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in consumer self-service areas.
Item No.: 36
Site: Galley-Galley and Pantry and Bakery
Violation: The artificial light level behind and beside the combination ovens in the main galley and the bakery were below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 41
Site: Housekeeping-Toilet Room Doors
Violation: The doors to the individual toilet stalls did not have the signs reminding individuals to use towels or tissue to open the door when exiting. The appropriate signs were added during the inspection.
Recommendation: Post a sign advising users of toilet facilities to use hand towel, paper towel, or tissue to open the door unless the exit is hands free.
Item No.: 41
Site: Housekeeping-Outbreak Prevention and Response Plan
Violation: The current Outbreak Prevention and Response plan did not include the specifics on the types of disinfectants used and the method to monitor their concentration and application. It did not detail specific passenger protection protocols. The outbreak communication plan to pax and crew was not detailed.
Recommendation: Ensure each vessel has a written OPRP that details standard procedures and policies to specifically address AGE onboard. Include the following in the written OPRP: (3) Disinfectant products or systems used, including the surfaces or items the disinfectants will be applied to, concentrations, and required contact times. Ensure the disinfectant products or systems are effective against human norovirus or an acceptable surrogate (e.g., caliciviruses); (4) Procedures for informing passengers and crew members of the outbreak. Ensure this section also includes procedures for notification of passengers embarking the vessel following an outbreak voyage or segment of a voyage; (6) Procedures to protect the passengers and crew from exposure to disinfectants, if not already included in the vessel?s safety management system. Ensure this protection includes: (a) Material safety data sheets (MSDSs); (b) Personal protective equipment for crew; (c) Health and safety procedures to minimize respiratory and dermal exposures to both passengers and crew.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program